215Ah 6V Battery Specifications

Crown Battery Manufacturing’s team of product and application experts
welcome the opportunity to discuss your technical requirements during
the design and specification stage. To access this support, please contact:
BCI
Group
Size
Model
Description
Nominal
Voltage
Length Width
Container
Height
Terminal
Height
Weight
Cover &
Container
Material
Case to Cover
Seal Method
in mm in mm in mm in mm lbs kgs
6V-27 6CRV215 6 12.05 306 6.89 175 7.9 6 202 8.08 205 65 29.5 Polypropylene Heat Seal
Power. Sheet.
6CRV215
AGM Deep Cycle
THE POWER OF 1
VRLA AGM | Non-Spillable | Maintenance-Free
TERMINAL STYLE
Inserted M6
Ampere Hour Capacity (Ah) Discharge Capacity Minutes KWH (kWh) Int Res. Short Circuit Current
CCA CA 100 Hr 20 Hr 5 Hr 75A 25A 20A 15A 5A 100 Hr 80°F / 27°C Amperes
670 835 228 215 175 100 385 524 770 3330 1.33 1.12 3530
ELECTRICAL SPECIFICATIONS
PHYSICAL SPECIFICATIONS
State of Charge Percentage 100% 75% 50% 25% 0%
Open Circuit Voltage - Cell 2.14 2.09 2.04 1.99 1.94
Open Circuit Voltage - Battery 6.42 6.27 6.12 5.97 5.82
AGM BATTERY STATE OF CHARGE MEASUREMENT
Operating Temperature Range Self Discharge
Terminal & Torque Specications
Best Practices
Maximum Limit -4°F to 120°F
(-20°C to 49°C) with proper temperature
compensation controls. Lead acid
batteries are temperature sensitive: refer
to the temperature / capacity projection
chart to identify available capacity at the
application operating temperature.
Application Note: Maintain a state
of charge greater than 60% when
operating batteries at temperatures
below 3F (0°C).
Approximately 3% per
month at 8F (27°C).
Rate of self discharge
will vary depending on
storage temperature.
SAE / Automotive Terminal:
50 to 70 in-lbs / 6 to 8 Nm
Stainless Threaded Terminal:
100 to 120 in-lbs / 11 to 14 Nm
Fastener Type:
M6 – 20 S/S Hex Flange
Headed Bolt
Battery terminal connections
should be secured and tight at all
times. Replace torn or damaged
cabling or connectors.
Safety is Your Responsibility! Keep sparks, flames and cigarettes
away from batteries at all times. Maintain good ventilation when
working on or charging batteries.
Keep batteries and terminal connections clean, dry and free of dirt and
corrosion. Do not tamper with vent structures. Optimize the life of your
batteries by limiting duty cycle depth of discharge to 75% or less.
Charging service must be performed with equipment configured to
support the charging recommendations herein. Opportunity charging
service can be performed when batteries are no more than 50%
discharged. Batteries must be fully recharged after the termination of
duty cycle usage.
APPLICATION NOTES
Crown Battery Manufacturing’s
Product Support Department
+
1.419.334.7181 / Fax
+
1.419.334.7124
commercial@crownbattery.com
1445 Majestic Drive | P.O. Box 990 | Fremont, OH USA | 419.334.7181 | Fax 419.334.7124 | www.crownbattery.com