INTRODUCTION
This DECT ULE FLD detector is an advanced, fully
supervised low-current wireless detector that
includes a DECT ULE transceiver for reliable
system operation.
A dedicated cable is supplied with this device.
This DECT ULE FLD uses smart message control,
which verifies that all messages are successfully
transmitted, so that no event will be uninformed to
the system.
This DECT ULE FLD detector includes series of
messages for full communication administration
(Keep Alive, Tamper Status, Battery Status, Alert,
Configuration, etc.) as well as test transmission
signals.
FEATURES
DECT ULE RF protocol.
Low current Technology.
Powered by a single 3V Lithium battery.
Battery life: up to 4 years.
Frequency Band: All DECT Standard Bands.
Tamper Open/Close transmission.
Keep Alive transmission.
Battery status transmission.
Bi-Color LED indications for monitoring &
Pairing.
Range up to 500m on open space.
Back tamper.
Alarm triggered by the sensor on the edge of
the cable.
Remotely configurable.
Friendly Pairing and Installation processes.
4
5
6
OPERATION
The DECT ULE FLD detector transmits the
following events data:
KEEP ALIVE A periodical transmission
indicating detector’s presence. The time interval is
configurable the minimum value is 3 seconds.
ALARM Alarm transmission triggered by the
Flood indicating on water leakage detection. The
Red LED will blink once.
LOW BAT Whenever the battery reaches a pre-
set low level (~2.5V) Battery Low signal will be
sent. When the Battery level drops below Cut Off
level (~2.3V) the device will stop functioning and
the Red LED will constantly light On.
TAMPER Whenever the DECT ULE FLD cover
is removed or tore off the wall, a message will be
transmitted with “Tamper” signal.
PREPARE THE DEVICE FOR
INSTALLATION
1. Open the screw cover and unscrew the holding
screw as shown in Figure 1.
2. Separate the device from the Bracket by tilting
the front cover as shown in Figure 1.
3. Break one piece of the Bracket corners
according to the device installation orientation
(Horizontal/Vertical) as shown in Figure 2.
4. Genteelly connect the Flood sensor cable to its
place as shown in Figure 3. Be aware that the
connector can be inserted in only one direction.
5. In case you wish to install the device using the
adhesive strips then attached them to the
device and to the Flood sensor.
6. Continue with the pairing process.
FIGURE 1 SEPARATE FROM BRACKET
7
8
9
FIGURE 2 DEVICE ORIENTATION
FIGURE 3 INSERT THE CABLE
PAIRING PROCESS
1. Place a battery as instructed in Figure 4 and
wait until the Red LED stops blinking.
2. Initiate the Base Station pairing process.
3. Initiate the device pairing process by pressing
the pairing button for 5 seconds the pairing
button is shown in Figure 5. The Green LED will
constantly turn On. When the Green LED starts
blinking release the pairing button.
4. The device should register to the Base Station.
5. When registration process is successfully
completed the Green LED will constantly light
On for 3 seconds and then turn Off.
6. If the registration process failed the Red LED
will blink (remove the battery and run the pairing
process again).
10
11
12
FIGURE 4 BATTERY INSERTION
FIGURE 5 PAIRING BUTTON
SELECT MOUNTING LOCATION
It is recommended to mount the device vertically on
a flat area to get maximum range.
As the detector is a wireless transceiver, and in
order to take full advantage of its sophisticated
operation, do not install the detector in areas where
large metal objects could interfere with the
transmission of signals.
TRANSMISSION TESTS
Tamper transmission test
Changing the tamper switch state (by attaching /
removing the device to / from the Bracket) will
cause tamper transmissions. Verify receiving the
indication on your Application / Base Station.
Identification transmission test
Use your Application / Base Station and send
Identification Request to the device. The device
will start blinking the Green & Red LEDs
alternately 5 times each LED starting with the
Green LED.
Vertical
Installation

Summary of content (2 pages)