MP_PS User Manual Remote Unit Model No: PS-R2220708 MP_PS MID POWER Digital Radios 37dBm per Band
Mid POWER Digital Radio Revision History Revision Number Revision Date Summary of Changes Author 1.0.0 28th Draft WANG XIAN June 2020 Copyright © 2020 Sunwave All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from Sunwave.
Mid POWER Digital Radio Content Preface .................................................................................................................................................................................... 5 Warnings ............................................................................................................................................................................. 5 Site Considerations ...................................................................................
Mid POWER Digital Radio Optical Transceiver Module .............................................................................................................................................. 45 Single Port Bidirectional SFP Transceiver...................................................................................................................... 45 Dual Port SFP Transceiver .............................................................................................................................
Mid POWER Digital Radio Preface Warnings All the following “Safety Precautions” must be observed during the entire installation and operation of the CrossFire system. The CrossFire system components are designed for maximum safety and reliability when they are installed, used, and maintained by trained and qualified technicians following the procedures and instructions contained in this manual.
Mid POWER Digital Radio This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
Mid POWER Digital Radio Warning Marks The warning marks on the CrossFire shell should be kept clean, readable, and identifiable. ALWAYS disconnect all lines and power connections before servicing or disassembling this equipment. NEVER touch the surface after power on the devices. For performance and safety reasons, NEVER disassemble and remodel the devices. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio Installation Preparation Unpacking and Inspecting This section discusses the procedures for receiving the shipment, inspecting the packing container, unpacking, and inspecting the device. Inspecting the Packing Container Handle the packing container carefully. Inspect the packing container immediately on arrival at the installation site to verify that no apparent damage occurred during shipment.
Mid POWER Digital Radio Verifying the Contents To verify the contents of the package: 1. Verify that the contents and quantities agree with the Delivery Packing List. 2. Check the device model against the Delivery Packing List. 3. Notify SUNWAVE immediately if any discrepancies are discovered, to verify whether the complete and correct shipment has been received.
Mid POWER Digital Radio Installation Tools The following equipment and tools are required for a successful installation: Electric percussion drill / Screwdriver / Wrench Torque Settings Type M3 M6 M10 Specified Torques 0.6Nm 5Nm 50Nm Clearance You must ensure the following mounting clearances for mounting within a 19” rack/cabinet: Convection cooling: Maintain 3U clearance between the bottom of the device and any other.
Mid POWER Digital Radio Installing the Access Unit (AU) Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio Accessories List Rack Installation The Access Unit is a 19” 1U equipment shelf. When installing the Access Unit in a rack, make sure the mechanical loading of the rack is even to avoid a hazardous condition. The rack should safely support the combined weight of all the equipment and be securely anchored. Installing the Access Unit in a climate-controlled room with sufficient air circulation is recommended as the maximum ambient temperature is +50°C.
Mid POWER Digital Radio Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 2. Recommended attaching the sliding rails to rack. (Not included in delivery). Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 3. Place the AU in the rack and secure the AU using 2 screws M6×16 on both sides and the Phillips screwdriver. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 4. Install the fan for cooling if multiple AUs are installed in the same rack. It is necessary to allow at least 3 rack units (132mm) of free space below each unit for heat dissipation without fan installed or 1 rack unit (44mm) of free space below each unit with fan occupied in the middle. Otherwise, the device temperature may rise and affect the service life of the device. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 5. Connect and lock the power cable at the AU rear side. 6. Connect and screw the ground wire at the AU rear side. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio Wall Installation To install the Access Unit on the wall: 1. Rotate the handles 90°and attach them at the rear of the AU, using 4 screws M3×6 per bracket and the Phillips screwdriver. Observe the orientation of the brackets. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 2. Mark 4 x ∅6.8mm drilling holes sites for the hanger to be attached to the wall. 3. Drill 4 holes at the marked sites using percussion drill and embed 4×∅10 plastic expansion pipes. Note: H=70mm. Fasten the case with 4×M6 expansion bolt. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 4. Connect and lock the power cable at the AU rear side 5. Connect and screw the ground wire at the AU rear side Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio AU Mounting Dimension Spacing Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio RF Connection The RF interface between the Access Unit and the service provider signal source (or CrossFire CPOI) is provided by duplex connections on the Active Combiner module. To route and connect the coaxial cables to the Access Unit: 1. Obtain the required lengths of high performance, flexible, low loss 50Ω coaxial cable for all coaxial connections and route the cables from the signal source or CPOI to the Active Combiner module. 2.
Mid POWER Digital Radio Installing the Remote Unit (MP_PS) MP_PS Accessories Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio Wall Installation (Back on the Wall) 1. Attach and fasten the handle to the side of MP_PS with screws M6×14 using T5 Wrench. 2. Attach and fasten the Bracket I to the back of MP_PS with screws M6×14 using T5 Wrench. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 3. Mark the position of the drilling holes in the mounting Bracket II. Note: R=13mm. 4. Drill 4 holes at the marked positions. Note: H=70mm 5. Attach the dowels, expansion screws or the like and fasten the Bracket II to the wall. Tips: use Bracket II as a reference to control each devices’ separation distance before hanging and locking MP_PS up. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 6. Hang the MP_PS on the mounting bracket II and fasten with nuts M10. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 7. Fasten the Bracket I and II with screws M6×14. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 8. Connect and lock the power cable 9. Connect and screw the ground cable Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 10. Connect and tighten the waterproof network cable Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 11. Connect and tighten the waterproof optical fibre Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio Wall Installation (Side on the Wall) Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 1. Attach and fasten the handle to the side of MP_PS with screws M6×14 using T5 Wrench. 2. Attach and fasten the Bracket I to the left side of MP_PS with screws M6×14 using T5 Wrench. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 3. Mark the position of the drilling holes in the mounting Bracket II. Note: R=13mm. 4. Drill 4 holes at the marked positions. Note: H=70mm. 5. Attach the dowels, expansion screws or the like and fasten the Bracket II to the wall. Tips: use Bracket II as a reference to control each devices’ separation distance before hanging and locking MP_PS up. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 6. Hang the MP_PS on the mounting bracket II and fasten with nuts M10. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 7. Fasten the Bracket I and II with screws M6×14. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 8. Connect and lock the power cable 9. Connect and screw the ground cable Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio MP_PS Wall Mounting Dimension Spacing Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio Pole Installation 1. Install the handle and Bracket I to the back of MP_PS. 2. Install the bracket II and Bracket III to the pole. 3. Hang the MP_PS on the mounting bracket and fasten with nuts M10. 4. Connect the ground cable and power cable. Note: The diameter of Pole shall not be over 110mm or less than 55mm. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio Rack Installation Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 1. Attach and fasten the Bracket III to the Standard 19’ Rack with screws Note: Please purchase Bracket III for rack installation separately. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 2. Attach and fasten the handle to the side of MP_PS with screws M6×14 using T5 Wrench. 3. Attach and fasten the Bracket I to the back of MP_PS with screws M6×14 using T5 Wrench. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 4. Hang the MP_PS on the mounting bracket and fasten with nuts M10. Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio 5. Connect the ground cable and power cable. 6. Connect and screw the ground cable Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio MP_PS Wall Mounting Dimension Spacing Contact us today: www.sunwave.com cf_support@sunwave.
Mid POWER Digital Radio Optical Connection Optical Transceiver Module Single Port Bidirectional SFP Transceiver The Figure below shows a pair of single port Bidirectional SFP transceivers. For devices optical connection, the transceivers of two sides must be paired - the wavelength of one side is 1271nm, and the wavelength of another side is 1331nm. Otherwise it will fail the connection. All lower-level devices under this port won’t be working in system.
Mid POWER Digital Radio Optical Indicator Each pair (2) of optical module cages has four LED indicator arrows. The two on the left are green, and the two on the right are red as shown in Figure below. The indicator arrows represent the synchronization status of the upper and lower optical modules. When a pair of optical modules are synchronized (both uplink and downlink), the indicators turn green as shown in the right pair of indicators in Figure below.