Model 2415-x02 Instruction Manual Four Channel Upconverter 2415-402 Four Channel • 2415-302 Three Channel • 2415-202 Two Channel • 2415-102 One Channel February 2015, Rev. A MODEL 2415 ------ CH 1 -------- ------ CH 2 -------- 1 2 3 4 A B ALARMS 1674.125 1926.375 1926.250 2086.625 UPCONVERTER MENU CROSS TECHNOLOGIES INC.
INSTRUCTION MANUAL Model 2415-x02 Multi Channel Upconverter TABLE OF CONTENTS PAGE Warranty 1.0 General 1.1 Equipment Description 1.2 Technical Specifications 1.3 Monitor & Control Interface 1.4 Environmental Use Information 2.0 Installation 2.1 Mechanical 2.2 Rear Panel Inputs & Outputs 2.3 Front Panel Controls & Indicators 2.4 Operation 2.5 Menu Settings 3.0 Ethernet Interface 3.1 Connection 3.2 Ethernet Configuration 3.3 Webpage M&C 3.
Model 2415-x02 Multi Channel Downconverter 2415-402 Four Channel • 2415-302 Three Channel • 2415-202 Two Channel • 2415-102 One Channel 1.0 General 1.1 Equipment Description The 2415-402 Upconverter has four individual channels, each one converts 70 MHz to 950 to 2150 MHz in 125 kHz steps with low group delay and flat frequency response. Synthesized local oscillators (LO) provide frequency selection. Push button switches select the output frequency, gain, and other parameters.
TABLE 1.0 2415-x02 Multi-Channel Upconverter Technical Specifications** Input Characteristics Impedance/Return Loss Frequency Input Level Range Output Characteristics 75Ω/18 dB (See Table 2.2 for connector options) 70 ±18 MHz -35 to -10 dBm Impedance/Return Loss 75Ω / 12 dB (See Table 2.2 for connector options) Frequency 950 to 2150 MHz Output Level Range Output 1 dB compression -20 to 0 dBm +10 dBm, maximum gain Channel Characteristics Gain Range (adjustable) 0 to +30.0 dB in 0.5 ±0.
(Technical Specifications continued from page 4...) Available Options H- High Stability (±0.01 ppm) internal ref. V1 - SSPB DC, CH1(ONLY), +24VDC, 2.
A) Remote serial interface Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit.
Table 1.1 lists the status requests for the 2416-x02 and briefly describes them. * PLEASE NOTE: Status requests of values specific to a channel must be preceded by a *i where *i is the channel number. * PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485 is selected. TABLE 1.
(Status Request continued from page 7...) TABLE 1.1 2415-x02 Status Statu us Requests Continued Co ontinued Command Syntax* Description Get IF Frequency {aa*iSY} Returns {*iSYx} where : (Option W160/70) • i = 1, 2, 3 or 4... • x = 0 for 70 MHz IF, 1 for 160 MHz IF Get IP address {aaSi} Returns {Sixxx.xxx.xxx.xxx} where : 28, enabled) (If Ethernet Option, W8, W18, or W2 • xxx.xxx.xxx.xxx = IP address Get subnet mask Returns {Ssxxx.xxx.xxx.
Table 1.2 lists the commands for the 2415-x02 and briefly describes them. After a command is sent the 2415-x02 sends a return “>” indicating the command has been received and executed. General Command Format - The general command format is {aaCND...
1.4 Environmental Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. B. Mechanical loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. C.
2.0 Installation 2.1 Mechanical The 2415-x02 consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switching, ±12, +24, +5 VDC power supply provides power for the assemblies. The 2415-x02 can be secured to a rack using the 4 holes on the front panel. Figure 2.1 shows how the 2415-x02 is assembled. POWER SUPPLY POWER SUPPLY FIGURE 2.1 2415-x02 Mechanical Assembly (Shown, Model 2415-402 - Four Channel) 2415-x02 Manual, Rev.
2.2 Rear Panel Input/Output Signals Figure 2.2 shows the input and output connectors on the rear panel. PSA & PSB - POWER IN AC input for switching power supply. 100-240 ±10% VAC, 47-60 Hz. J5- IF IN 70 MHz Input, -35 to -10dBm. 75Ω BNC J1- IF IN 70 MHz Input, -35 to -10dBm. 75Ω BNC PSB PSA CHANNEL 1 IF IN GND VDC ON RF RF OUT 10 MHZ IN/OUT CHANNEL 2 10 MHZ REF 10 MHZ REF INPUT OUTPUT IF IN J11 - ETHERNET CONNECTION (option W8) RJ45 Ethernet Connector J9- IF IN 70 MHz Input, -35 to -10dBm.
2.3 Front Panel Controls and Indicators - The following are the front panel controls and indicators. DS1 - REMOTE LED Yellow LEDs indicates remote operation. LCD FRONT PANEL DISPLAY Shows parameter selection and frequency and gain settings for channels 1, 2, 3, & 4. -------- CH 1 -------- 1 3 2 A 4 B ALARMS REMOTE 1674.125 1926.375 -------- CH 3 -------- FIGURE 2.3 -------- CH 2 --------- 1926.250 2086.
2.4 Operation 2.4.1 Installing and Operating the 2415-x02 Upconverter 1. Connect a -35 dBm to -10 dBm signal to IF IN, for the designated channel (ie: J1, J5, J7, J9), (Figure 2.2). 2. Connect the RF OUT, for the designated channel (ie: J2, J6, J8, J10), to the external equipment, (Figure 2.2). 3. Connect 100-240 ±10% VAC, 47 - 63 Hz to AC on the back panel. 4. Set the input frequency (See Section 2.5 Menu Settings). 5. Set the “Input Level” to reflect the level of the signal applied to the IF input. 6.
2.5 Power On Settings Figure 2.5 shows the various Front Panel LCD Displays that you will see during the Power Up sequence and the Settings modes. The first two displays (Power Up, displaying Model Number, Rev. Level and IP Address are only displayed briefly during the Power On sequence. The Normal Display is what you will see while the unit is in normal operating mode. When power is first applied, the LCD display goes through three steps. 1. The model number and options will be displayed. 2.
2.5.2 Frequency Changes At any time during the modification process, if you have made a mistake and do not wish to save the changes you have made, do not press the Menu/Execute switch; simply do nothing for approximately 30 seconds, and the system will return to the normal operating mode or scroll to “R” and push the menu/Execute switch and select “NO” in the “SAVE SETTINGS?” window. To change the FREQUENCY: Operate the Menu/Execute switch until you get to the menu item you want to change. See Figure 2.
2.6 Menu Settings All program changes must start with the operation of the Menu/Execute switch and must also end with the operation of the Menu/Execute switch verified by the “Save Settings?” Menu. If this sequence is not followed, none of the changes will take effect. If programming is initiated and no operator action takes place for approximately 30 seconds (before the final press of the Menu/Execute switch) the display will revert to its previous status and you will need to start over.
3.0 Ethernet Interface Installation and Operation (Option W8, W18 or W28) This manual applies to Cross Technologies products equipped with a 10/100 Base-T compatible Ethernet interface for control and monitoring of its operating parameters. The following sections describe the operation and setup of those interfaces. An HTML script interface allows the user to monitor and control the converter using a standard web browser. SNMP (Simple Network Management Protocol) is also supported.
Figure 3.1: Configuration Manager Screen (Example above shows Configuration Manger Screen for Model 2415-402) Once logged in, you will be presented with the Configuration Manager web page. In the left frame of the configuration manager click on Network to display the Network Settings screen. Enter the IP address, Subnet mask, and Gateway address with delimiter dots (example: 192.168.123.2 (Default)). Click “Apply Settings” in the left frame to apply the new settings in the network device.
Figure 3.2: Network Settings Web Page Screen (Example above shows Network Settings Screen for Model 2415-402) 2415-x02 Manual, Rev.
3.3 Web Page M & C Enter the following address in a web browser to access the M&C web page: http:///serial/0/setup.htm where is the IP address of the 2415-x02. Figure 3.3 (example below) shows the web page from model 2415-402 frequency converter. Figure 3.3: Model 2416-x02 Web Page (Example above shows M&C Web Page for Model 2415-402) 2415-x02 Manual, Rev.
3.4 SNMP Configuration Setting of SNMP parameters such as Community Write and Community Read strings requires a Telnet® connection to port 9999. The following instructions explain how to establish such a Telnet connection using Windows XP's utility Hyper Terminal. Start the Hyper Terminal application and select “New Connection” from the “File” drop down menu. The next screen is a “Connect To” dialog box. 1. Enter the IP address of the 2416-x02 in the “Host address:” field. 2.
If you select Public, access is allowed for any number of authorized IP addresses of SNMP Managers. It is not required to enter IP Addresses of SNMP Managers. Figure 3.5: Device Server Configuration Menu Once you have completed you SNMP set up, select item #9, “SAVE AND EXIT” 2415-x02 Manual, Rev.