Crestron CWD1014 Two-Way RF Transceiver Module Operations Guide
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2007 Crestron Electronics, Inc.
Crestron CWD1014 Two-Way RF Transceiver Module Contents Two-Way RF Transceiver Module: CWD1014 ............................................. 1 Introduction................................................................................................................................1 Functions and Features ................................................................................................1 Specifications .........................................................................................
Crestron CWD1014 Two-Way RF Transceiver Module Two-Way RF Transceiver Module: CWD1014 Introduction Functions and Features The CWD1014 (hereafter referred to as “module”) is a two-way radio frequency (RF) module that utilizes the 2.4 GHz frequency band to communicate with other devices. The module operates according to the IEEE 802.15.4 specification and can be configured to minimize the possibility of interference with other devices.
Two-Way RF Transceiver Module Crestron CWD1014 Specifications The table below is a summary of specifications for the CWD1014. Specifications of the CWD1014 SPECIFICATION DETAILS Power Requirements 0.75 Watts (3.3VDC @ 0.250A) Operating Frequency 2400 MHz to 2483.6 MHz (802.15.4 compliant) Operating Ranges¹ Minimum Distance 3 ft Maximum Distance Indoors (without repeater device) 100 ft Available Channels 16 (numbered 11 through 26 per 802.15.
Crestron CWD1014 Two-Way RF Transceiver Module CWD1014 Detail Views 1.00 in (2.54 cm) 0.35 in (0.89 cm) 1.54 in (3.91 cm) Ports The module contains 24 solder points and one antenna port. Refer to the diagrams and descriptions that follow. Power/I-O Twenty-four solder points provide power to the module as well as serial communications between the module and wired devices. Refer to the following table for pin assignments of the module interface connector.
Two-Way RF Transceiver Module Crestron CWD1014 Antenna This SMA non-standard male antenna port is located at edge of the circuit board for attaching the included dipole antenna. APPROVED ANTENNAS: The CWD1014 antenna interface has a unique coupling designed to ensure that no antenna other than the one supplied shall be used with the device. Replacement antennas may be purchased from Crestron according to the following description: Part Number: 2001016 Description: ANTENNA, 2400.
Crestron CWD1014 Two-Way RF Transceiver Module Antenna Requirements: The module must be installed such that the antenna connector is accessible for direct antenna connection in the final configuration. If any cable or antenna other than that provided with the CWD1014 is used, then the FCC authorization is no longer considered valid and the FCC ID cannot be used on the final product.
Two-Way RF Transceiver Module Crestron CWD1014 FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device is intended only for OEM integrators under the following conditions: 1.
Crestron CWD1014 Two-Way RF Transceiver Module End Product Labeling The final end product must be labeled in a visible area with the following: “Contains FCC ID: EROCWD1014 . Documentation The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the users manual of the end product which integrate this module.
This page intentionally left blank Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Operations Guide - DOC. 6658 01.08 INTERNAL USE ONLY Specifications subject to change without notice.
Crestron CWD1014 Operations Guide - DOC.