CPI G7 Smart 7 Install Guide G7 Smart 7 Install Guide v. 1.0.3 G7 Smart 7 Install Guide EN v1.0.2.docx 1 / 13 01.04.
CPI G7 Smart 7 Install Guide Author: Revised: Filename: Copyright: Wolfgang Renner, 23 January 2020 W.Renner, 1 April 2020 G7 iSmart 7 Install Guide EN.docx Crane Payment Innovations AG Nordringstrasse 16 CH-4702 Oensingen Tel: +41 62 388 45 45 Fax: +41 62 388 45 55 COPYRIGHT © 2020 Crane Payment Innovations The information contained herein is the Crane Payment Innovations.
CPI G7 Smart 7 Install Guide Table of Contents 1 Introduction...........................................................................................................................................4 2 Smart 7 Hardware .................................................................................................................................4 3 2.1 Smart 7 MDB .......................................................................................................................................
CPI G7 Smart 7 Install Guide 1 Introduction This document describes the CPI Generation 7 iSmart Readers Firmware- and Configuration install and set up procedures. It considers the basic differences between the previous reader generations in terms of set up, operating and testing procedures. 2 Smart 7 Hardware The Smart 7 comes in two different Type Models, the Smart 7 MDB and the Smart 7 RS232. Each of them are available in two versions, with display and without display. 2.
CPI G7 Smart 7 Install Guide 3 Smart 7 Install and Configuration Unlike previous Generation 6 devices, the G7 Reader Configurations will only been managed via the e-Vending online platform, which also provides the most recent Firmware versions for the hardware. An Additional software tool, like the Generation 6 MDSmanager, is neither required nor supported anymore in Generation 7. This also means no backward compatibility to G6 configurations.
CPI G7 Smart 7 Install Guide 3.1.1 Edit Configuration Basically each reader comes with a default configuration. Unless it will be edited, the Default Configuration can be downloaded with the “Generate Config. File” button to the computer and transferred to the reader, either directly or via USB Stick. By clicking on the “Edit” button, the configuration menu opens and the Reader Configuration can be edited individually according to specific requirements and their corresponding settings.
CPI G7 Smart 7 Install Guide 3.1.3 Archive File Format The configuration file isn’t downloaded to the reader directly but is included in an archive file that is downloaded to the reader. It comes within a compressed *.tar archive, including 5 encrypted .fcon files. The reader unpacks the archive verifies the integrity of its content and then copies the configuration file to the appropriate location on the reader.
CPI G7 Smart 7 Install Guide For the update process via USB Stick, the reader must be powered via MDB / RS232 connection, respectively needs to be connected to the VMC or peripheral device. As soon as the USB Stick / Cable is connected, the reader switches into Service Mode and the MDB communication will be on hold. The display shows “Service Mode” and the orange LED is blinking. The Smart 7 performs the install / update process and restarts when the USB Stick / cable is removed.
CPI G7 Smart 7 Install Guide 4 Smart 7 Status and Display Messages The Smart 7 DIS versions provide status- operation- and maintenance information by a list of Display Messages given in 4.1 while the Smart 7 MBH variants provide basic information via Status LED only. 4.1 Display Messages The status messages on display will show up as listed below and simultaneously give the corresponding LED status signals shown in 4.
CPI G7 Smart 7 Install Guide 5 Support Packages If an USB Stick is connected to the Reader, it goes into Service Mode and a Service Package will be created and copied to the USB Stick. When the USB Stick is removed, the Reader performs a reset. When connecting a USB Cable, a Service Package will be created immediately. This is included in a SPK .tar file and can be copied to the PC. For Technical Support it can be uploaded to the e-Vending Portal or send to CPI mic_support@cranepi.
CPI G7 Smart 7 Install Guide 5.2 Logs The Logs folder includes the Config- and Error log files …. … which can be viewed in Notepad 5.3 Protocols The protocols are in .pco format and can only be viewed in CPI FileExplorer, respectively by CPI Support Staff. 5.4 Selections Selection list is also in .json format and can be read with the viewer or Notepad. G7 Smart 7 Install Guide EN v1.0.2.docx 11 / 13 01.04.
CPI G7 Smart 7 Install Guide 5.5 Statistics The reader Statistics are provided in .DTS text format, the same as it was in previous Generation 6 readers. It can be read in MDSview 5.6 Taglist Taglists includes a system information file, which is always encrypted. G7 Smart 7 Install Guide EN v1.0.2.docx 12 / 13 01.04.
CPI G7 Smart 7 Install Guide 6 Attaching the device The Smart7 devices can be fixed with the M 4 x 15 screws coming within the box, according to the fitting scheme below: A separate Drilling Scheme can printed in 1:1 scale to precisely drill the screwing holes. 7 Compliance: Supply Input: 12 - 40Vdc Power: 3 W. USA - FCC ID: QP8SMART7 Canada - IC: 1297A-SMART7 "This device complies with Part 15 of the FCC Rules.