Remote Data Port Install Guide Model: Part No.: Serial No.: Voltage: 24-34VDC, 0.5AMPS 1301 Wilson Drive West Chester PA 19380 www.meieasitrax.com Mars Inc. 2003 Printed in USA. MEI is a trademark of Mars, Inc. Information is subject to change without notice. MEI has made every effort to ensure that the information in this document is accurate. However, we cannot be held responsible for any errors or omissions. Technical Support 1-800-345-8172 www.meieasitrax.
TABLE OF CONTENTS INTRODUCTION General Information .............................................................................................. 3 Product Features .................................................................................................... 3 Interfaces Supported ............................................................................................. 3 PRODUCT OVERVIEW Serial Number................................................................................................
INTRODUCTION GENERAL INFORMATION The remote data port lets you add industry-standard DEX data transfer capabilities to machines that are not audit enabled or add enhanced capabilities to DEX-enabled machines. The remote data port gathers data on cash transactions and vending cycles, including coin drops, bill insertions and product sales. This information is stored for later collection. The remote data port is compatible with most vending machines and is simple to use and install.
PRODUCT OVERVIEW SERIAL NUMBER CONFIGURATION WW Y L CC PPPPP - WWYLCCPPPPP Week Manufactured (01 through 52) Year Manufactured (2 for 2002) Manufacturing Location Configuration Code Sequential Production Number CONFIGURATION The remote data port will be shipped with factory default settings. Each remote data port will require machine specific configuration using an MEI Support Tool. See MEI Easitrax Remote Data Port Configuration manual for instructions.
PRODUCT OVERVIEW MEI EASITRAX VT 1000 (LMM) The MEI EASITRAX VT 1000 is used when monitoring product vend cycles. It allows for high voltage monitoring of linear vend motors, credit line and cash counter. P1 Data Port Interface P2 Linear Motor P3 Cash Counter MEI EASITRAX DATA POD 200 (DMMM) The MEI EASITRAX data pod 200 is used when monitoring product vend cycles. Its voltage source is the data port. It allows for 5V logic to monitor matrix vend motors.
AP-MACHINE INSTALLATION AP 6000 / 7000 Series Snack Machine Remote Data Port Installation This machine can utilize the Full Option and Cash Only Option. If you are utilizing the Full Option perform steps 1 through 15.
AP-MACHINE INSTALLATION 6) Connect the 12 Pin Micromech Cable (p/n 215630006) from the MEI coin changer to the Electro-Mechanical “Stub” Harness (p/n 215636003) coming out of the Remote Data P4 Connector.* 7) Connect the VFM Interface cable (p/n 214977001) from the bill Acceptor to the Electro-Mechanical “Stub” Harness (p/n 215636003) coming out of the Remote Data Port P4 Connector.* 8).
AP-MACHINE DIAGRAM Part No.: 216173001 Dex Socket (J1) P4 P5 p/n 214977001 p/n 215630006 p/n 215635012 p/n 215631014 P3 p/n 215636003 P2 p/n 215630001 P1 Data Pod 200 p/n 213662012 p/n 214919001 VMC p/n 214891001 Coin Mech Bill Acceptor Technical Support 1-800-345-8172 www.meieasitrax.
DIXIE-MACHINE INSTALLATION DN Single Price Machine Remote Data Port Installation This machine can utilize the Full Option and Cash Only Option. If you are utilizing the Full Option perform steps 1 through 13.
DIXIE-MACHINE INSTALLATION 6). Installing the ACD cable (p/n 215634009): -Connect the 6 pin ACD connector at the end of the MEI coin mech harness to the mating 6 pin connector on the ACD cable tap.* -Connect the ACD Cable tap connector marked P3 to the mating 10 pin connector of the Electro-Mechanical “Stub” Harness (p/n 215636003) that is already attached to P4 of the Remote Data Port.* 7).
DIXIE-MACHINE DIAGRAM Part No.: 216173001 Dex Socket (J1) P4 P5 p/n 215634009 ( From Key Table p.12) p/n 215638007 p/n 215631014 Machine Door Harness P3 p/n 215636003 P2 p/n 215630001 P1 16 Pin Connector VT 1000 LMM p/n 213663003 Coin Mech Bill Acceptor Technical Support 1-800-345-8172 www.meieasitrax.
DIXIE-MACHINE INSTALLATION Dixie Narco Motor Cable Chart Make/model DN – 8 DN – 7 DN - 7 803 DN – 7 DN – 6 DN - 5 603 DN - 5 603 DN – 6 DN – 5 DN - 7 803 DN – 9 DN –10 DN – 8 DN – 6 DN –10 DN – 8 DN - 7 803 DN – 8 DN – 6 DN – 5 DN - 7 803 DN - 7 803 DN – 6 DN – 6 DN – 8 DN – 6 DN - 7 803 DN – 8 DN – 8 DN - 7 803 DN - 7 803 DN - 7 803 DN – 8 DN – 8 DN - 7 803 DN – 8 DN – 10 Qualifier 803812110.11 803812150.11 803812150.11 803812150.11 803812340.01 803812350.01 803812370.01 803812380.01 803812540.
RMI-MACHINE INSTALLATION RMI 2000 / 8050 MEI EASITRAX Remote Data Port Installation This machine only utilizes the Cash Only Option. Required Components: Description Part Number MEI EASITRAX Remote Data Port MEI EASITRAX VT 1000 LMM ACD Cable Electro-Mechanical “Stub” Harness MDB Power Cable 24V Supply Cable 115V Power Tap Cable 216173001 213663003 215634009 215636003 215630001 215631014 215633013 WARNING Do Not drill into high voltage wiring when drilling any necessary mounting holes.
RMI-MACHINE INSTALLATION 8). To connect power to the Remote Data Port, make the following connections: Plug in the 6 pin MDB end of the 24V supply cable (p/n 215631014) into the MDB connector on the MDB power cable (p/n 21563001). Using the supplied 3M J-hook strips, attach the VT 1000 LMM module (p/n 213663003) near the top hinge of the machine’s door. Make sure that the location of the VT1000 LMM does not impede machine operation.
RMI-MACHINE DIAGRAM Part No.: 216173001 Dex Socket (J1) p/n 215636003 P4 p/n 215634009 P3 p/n 215630001 P2 p/n 215631014 P1 P5 Female Light Transformer Connector 115V Supply from VMC Male Connector p/n 215633013 Female Connector 16 Pin Connector Male Light Transformer Connector VT 1000 LMM p/n 213663003 Coin Mech Technical Support 1-800-345-8172 www.meieasitrax.
COMPLIANCE USA, (902-928Mhz) FCC ID: QP8-MEI915WLAN “This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.” “Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.