3300 Crane Way Williston, South Carolina 29853 Tel: 1-800-628-8363 CORA Installation Guide COR15x-US101 P/N: 250654053_G3
Contents Contents ................................................................................................ 2 Introduction .......................................................................................... 3 Ease of Installation(EOI) ........................................................................ 3 VendMAX .............................................................................................. 3 Components ........................................................................
Introduction This document details the installation, assignment and use of the CORA telemeter when combined with a cashless credit card bezel. This guide assumes that the operator has completed the on-boarding process required to establish a banking relationship with one of our available credit card processors. Ease of Installation(EOI) Once the physical installation is complete and CORA is powered on, the device will automatically assign with our Ease of Installation feature.
CORA Components Item # 1 P/N 400046 Description Verizon 4G CORA unit 4000xx AT&T 4G CORA unit 2 400048 4G LTE Antenna, Primary 3 400051 DEX Cable 4 400050 CORA MDB Power Cable Image Optional Parts Item # 1 P/N 214137050C 2 804930670 3 400011 Description 6’ DEX Extension Cable 1’ DEX Extension Cable IDTech Bezel Adaptor Cable 4 For technical assistance please contact our support team at 1-800-6288363 Monday through Friday, from 8am to 5pm Eastern.
Installation 1. Power off the machine. 2. Identify installation location Determine the best location for the antenna(s). Ensure they are placed as far as possible from interference sources like ballasts and transformers. Where possible, the antenna should be placed in an area where metal structure is limited. Please refer to 4G External Antenna Installation on the following page for more information.
the harnesses near the connections will reduce the stress on the connectors. 8. Dress the rest of the harnesses and secure them in place with zip ties. 9. Restore power to the machine and allow at least three minutes for CORA to complete the assignment process. This can be monitored on the cashless bezel display. See Assignment Messages on page six. 4G External Antenna Installation 1. Find a mounting location that will not interfere with the operation of the vending machine. 2.
6. Secure the antenna by tightening the lock washer and nut on the antenna post. 7. Plug the assembled 4G connector into the blue primary antenna connector. 7 For technical assistance please contact our support team at 1-800-6288363 Monday through Friday, from 8am to 5pm Eastern.
Connections LED/ Wrench Button DEX Socket MDB Connector Secondary 4G Connector (Gold) Cashless Bezel Primary 4G Connector (Blue) CPI Synq Touch Screen DEX Audit 8 For technical assistance please contact our support team at 1-800-6288363 Monday through Friday, from 8am to 5pm Eastern.
Assignment & Messages During the assignment process, CORA performs numerous checks (outlined below). These messages will be displayed on a cashless bezel if using Ease of Installation (EOI) or Crane Cashless App. Messages will start once CORA has completed its boot up. If you are a VendMAX customer using a handheld with VIX, you will receive the message “Use VIX to Assign.” At this point, connect your VIX handheld and complete the assignment.
Diagnostics Diagnostics can be used to obtain device information such as signal strength, DEX validation or performing a cashless system test. Start diagnostics by pressing the wrench button on the unit five times or swiping a Technician Card. The following diagnostics information will cycle through the display. Note: The Technician Card does not perform a test-vend, but it does test cashless authorization. Waiting for Network… ID1: SWCODE ID2: NVCODE Cashless Rev 3.01.
Wrench Button LED Codes LED Color Solid Green Blinking Green Blinking Red Solid White Solid Red Description Full boot & operational Attempting to get a DEX file Failed to get a DEX file Booting in progress Fault on unit Wrench Button Interface Wrench Button Press and hold for three seconds Press five times Press and hold for ten seconds Description Attempts to get a DEX file Enters Diagnostics Un-assigns the device Signal Strength Use diagnostics to obtain the signal strength of the cora device and comp
Regulatory CORA FCC ID: QP8CORABT (Verizon Network Operation) CORA FCC ID: QP8CORABTATT (AT&T Network Operation) Cora series Modular Data Port uses radio energy to communicate vending transaction activities to a remote host. CPI has not approved any changes or modifications to Cora. Any changes or modifications could void the user’s authority to operate the equipment. See 47 CFR Sec. 15.21 The Cora series complies with 47 CFR Sec. 15 of the FCC Rules.
Instrumentation (AAMI). This standard will allow manufacturers to ensure that cardiac pacemakers and defibrillators are safe from cell phone EMI. The FDA continues to monitor the use of cell phones for possible interactions with other medical devices. Should harmful interference be found to occur, FDA will conduct testing to assess the interference and work to resolve the problem. For more information reference sources for pacemakers can be found at U.S. Food and Drug Administration web site: www.fda.