Electrical Connections
Motor Specifications
The AC motor used on this saw is a capaci-
tor-start, non-reversible type. The models
covered in this manual have the following
specifications:
Specification: Model Model Model
113.196120 113.196320 113.196420
Rated H_P. 1.5 1.5 1.5
Max Developed HJ _. 2.5 2.75 3.0
Voltage 120 120/240 120/240
Amperes 11 12/6 13/6.5
Hertz, (cycles) 60 60 60
Phase single single single
RPM 3450 3450 3450
Arbor Shaft Rotation clockwise clockwise clockwise
Run Capacitor No No Yes
Note: If saw does not start when switched
on, immediately turn saw off and refer to
Troublestugoting. Leaving the switch on will
destroy the motor.
Power Supply
_WARNING
Saw is factory wired for 120V opera-
tion. Connect to 120V, 15-AMP
branch circuit and use 15-AMP time
delay fuse or circuit breaker.
Failure to connect in this way could
result in injury from shock or fire.
The saw must be properly grounded. Not all
outlets arc properly grounded. If you are not
sure that your outlet is properly grounded,
have it checked by a qualified electrician.
_WARNING
If not properly grounded, this power
tool could cause electrical shock,
particularly when used in damp
locations.
_WARNING
If electrical shock occurs, your
reaction to shock could bring hands
into contact with blade.
,_WARNING
To avoid electric shock or fire,
immediately replace worn, cut, or
damaged power cord.
The unit is wired for 120V and has a plug
that looks like this:
3-Prong
Plug
Grounding
Prong
Properly
Grounded
Outlet
The power tool is equipped with a 3-conduc-
tor cord and grounding type plug listed by
Underwriters' Laboratories. The ground
conductor has a green jacket and is attached
to the tool housing at one end and to the
ground prong in the attachment plug at the
other end.
The plug requires a mating 3-conductor
grounded type outlet as shown above. If you
have an outlet that is of the 2-prong type, it
is recommended that you have a qualified
electrician replace it with a properly ground-
ed 3-prong outlet.
42