DISHWASHER INSTALLATION GUIDE S P E C I F I C AT I O N S , I N S TA L L AT I O N , A N D M O R E
C OVE DIS HWAS HE R Contents Important Note 3 Cove To ensure this product is installed and operated as safely and efficiently as possible, take note of the following types of highlighted information throughout this guide: Dishwasher 4 Specifications Door Panel 7 9 Installation Troubleshooting 15 Features and specifications are subject to change at any time without notice. Visit coveappliance.com/specs for the most up-to-date information.
C OVE DIS HWAS HE R Product Information Important product information, including the model and serial number, are listed on the product rating plate. The rating plate is located on the left side wall of the unit. Refer to the illustration below. If service is necessary, contact Cove Factory Certified Service with the model and serial number.
S PECIF ICAT IO NS Opening Dimensions D I S HWAS HER 24" (610) MIN OPENING DEPTH TOP VIEW 34 1/2" 23 5/8" (600) OPENING WIDTH (876) OPENING HEIGHT SIDE VIEW FRONT VIEW NOTE: 3 1/2" (89) finished returns will be visible and should be finished to match cabinetry. 3/4" (19) 3/4" (19) TYPICAL TYPICAL 3 1/2" (89) 3 1/2" (89) FINISHED RETURN FINISHED RETURN 23 5/8" 23 5/8" (600) (600) FRAMELESS CABINETRY 4 | Cove Customer Care 800.222.
S PECIF ICAT IO NS Electrical Requirements Installation must comply with all applicable electrical codes. Any opening into the adjacent cabinet must meet the following: the longest dimension of the opening shall not be more than 11/2" (38). The edges of the opening must be smooth and round. Locate the electrical supply in an adjacent cabinet, within reach of the power cord. Refer to the illustrations below. A separate circuit servicing only this appliance is required.
S PECIF ICAT IO NS Plumbing Requirements Installation must comply with all applicable plumbing codes. Any opening into the adjacent cabinet must meet the following: the longest dimension of the opening shall not be more than 11/2" (38). The edges of the opening must be smooth and round. Locate the water supply and drain in an adjacent cabinet. If necessary, the drain tubing can be extended by a maximum of 5' (1.5 m). Route the water supply through the shaded area shown in the illustration below.
D OO R PANEL Door Panel S TAINLES S S T E E L PANE L C U S TO M PA N EL Stainless steel accessory door panels are available through an authorized Cove dealer. For local dealer information, visit the find a showroom section of our website, coveappliance.com. Finish all sides of the custom panel. They may be visible when the door is open. The thickness of the custom panel can vary.
D OO R PANEL Door Panel 7 Verify C U S T O M PANEL MOUNTING 1 Remove the template from the dishwasher door by extracting the screws, then discard the screws. the panel is secure against the dishwasher door, then insert a screw into each hinge to secure the bottom of the panel. Refer to the illustration below. 2 Place the custom panel face down on a protected work surface. 3 Position the template flush with the top and sides of the panel, then mark and drill holes.
I N S TALLAT IO N Installation P REPAR AT IO N R AC K R EM O VAL 1 Place Remove the racks prior to anchoring the unit. the unit in front of the opening. 2 For openings less than 24" (610) wide, remove the side spacers by pushing upward. Refer to the illustration below. 3 Measure the height of the opening, then adjust the leveling legs until the unit height is slightly less than the opening height. Refer to the illustration below.
I N S TALLAT IO N Installation I N S TALLAT IO N LEVELI N G For metal cabinet installations, contact Cove Customer Care for edge protector material prior to installation. To adjust the front, turn the leveling legs clockwise to raise and counterclockwise to lower the unit. Refer to the illustration below. 1 Insert the unit into the opening and pull the excess electrical and plumbing supplies through the access hole as the unit is being installed.
I N S TALLAT IO N Installation D OO R T ENS IO N ADJUSTME NT K I C K P LATE I N S TA LLATI O N The door tension can be adjusted to accommodate multiple panel weights. Panel weight can not exceed 16 lb (7 kg). Turn the adjustment nut clockwise to increase tension and counterclockwise to decrease tension. Refer to the illustration below. The kickplate must be removable for service. The floor cannot interfere with removal. 1 Finger-tighten 2 Place the adjustment bracket nuts.
I N S TALLAT IO N Installation K I C KPLAT E CLEARANCE K I C K PLATE It is possible to adhere a custom kickplate to the factory kickplate. The height and thickness can vary, provided it does not impede the door panel rotation. Refer to the illustration below. The upper right corner of any kickplate exceeding 3 3/8" (86) in height must be notched to allow for airflow. Refer to the illustration below.
I N S TALLAT IO N Installation Water Softener C OMPLET IO N 2 For For water softener models only, a salt compartment is located at the bottom of the interior. Refer to the illustration below. Softener salt is available through an authorized Cove dealer. 3 Install Prior to filling the salt compartment for the first time, fill the compartment with water. Water does not have to be added with subsequent refills. 1 Turn the water and electrical supply on.
I N S TALLAT IO N Water Softener WAT ER HAR DNESS Setting user options: For water softener models only, use the test strip provided and the chart below to determine the appropriate water hardness setting. Refer to the chart below to determine the water hardness setting. 1 Touch Cancel twice. 2 Touch and hold Options for approximately 3 seconds until “User Set Up” appears on the display. 3 Touch Options multiple times to scroll to Water Hardness.
T R O UB LES HO O TING Troubleshooting Dishwasher does not operate. • Verify power is on. • Verify electrical power to dishwasher and home circuit breaker is on. WARNING Follow all city and state laws when storing, recycling or discarding unused dishwashers. • Verify the child lock, Sabbath feature, and showroom mode are not turned on.
COVE APPLI ANCE , I NC. P. O. BOX 44848 MA D I SO N , WI 5 3 7 4 4 9013808 REV-B 4 / 2018 C O V EA P P L I A N C E. C O M 8 0 0 . 2 2 2 .