USER’S MANUAL Adjustable Bed Base HU10061 THIS INSTRUCTION BOOKLET CONTAINS IMPORTANT SAFETY INFORMATION. PLEASE READ AND KEEP FOR FUTURE REFERENCE. Please give us a chance to make it right and do better! Contact our friendly customer service department for help first.
E-mail US: cs.us@costway.com UK: cs.uk@costway.
Patent Pending 2-Year Parts and Labor on entire base Warranty. Attention: Read the following information before using this product. Failure to use a surge protection device could compromise safety or cause product malfunction and could void the electrical portion of your warranty. Electrical surges are by far the biggest cause of problems with electrical circuits. In order to help protect your investment in case of a power surge or outage, use an electrical surge protection device (not included).
PACEMAKER WARNING: The massage units in this bed produce mechanical vibrations that this warranty; (d) to damage to mattresses, fabric, cables, electrical cords or items supplied by dealers.
COSTWAY makes no other warranty expressed or implied, and all implied warranties of merchantability and fitness for a particular purpose are disclaimed by COSTWAY and excluded from this agreement. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to every purchaser. This warranty gives the purchaser specific legal rights, and the purchaser may also have other rights, which may vary from state to state.
This can fool the pacemaker into "thinking" you are engaged in some sort of physical activity and require a faster heart rate. You may experience a sensation similar to when you are exercising. Consult your physician for further information. PRODUCT RATINGS: The bed lift motors are not designed for continuous use of more than 2 minutes in an 18 minutes period, or approximately 10% duty cycle.
TO REDUCE THE RISK OF SHOCK, BURNS, FIRE OR INJURY: Make sure the base is in a flat position and the vibrating motors are turned off before unplugging the bed base from the power source. Always unplug the base from the electrical outlet before cleaning or servicing the base. If the cord or plug is damaged, discontinue use of the bed base. Contact a qualified service personnel for examination and repair. FCC COMPLIANCE: This device complies with part 15 of the FCC Rules for residential use.
Parts List All electronics and components that need to be installed are located in boxes under the foundation or attached to the frame. Make sure that all parts are counted before discarding the packaging materials.
HU10061 Electronics Quick Reference Guide Control Box Head Motor Foot Motor USB Pairing Power Supply Head Motor Foot Motor LED 09 Power Cord
Installation Guide Two people are required to set up the foundation. NOTE: To avoid damage to the foundation, always open the carton while the bed is in the flat position. 1. Open the shipping box and take out top decking.Cut the ribbon securing accessory Boxes&mattress retainer bar and put them aside. Carefully take out the bed frame from packaging and open it . 2. To Install all legs. thread the bolt of the leg to the nut on the foundation frame, and tighten by hand. DO NOT OVERTIGHTEN.
3. Carefully turn the base over without placing weight on the legs, to prevent bending. 4. Attach the deck sections. Place the top deck from head to foot accordingly (Please refer to the yellow stickers on the board and metal frame accordingly,as TXL Size:1-4,Q Size:1-5.Notice : The sides with stickers face up.), make the holes on top deck correspond to those on bed frame, and the screw the deck bolt into the holes. 5. Locate the mattress retainer bar brackets.
Finally, HU10061 Adjustable Base is completed as shown in picture below. 6. Uncoil the input power cord (connected to the control box’s power port) and plug it into the power supply. 7. Uncoil the power cord and connect it to the power supply. Ensure that batteries are correctly installed.
HU10061 Remote Control Instructions Flat Position Lifts and Lowers Foot Lifts and Lowers Head Zero Gravity Preset Position Pairing Remote The original remote that comes in the box is already paired to the foundation. No further action is required. In the event that the remote is not paired with the foundation, follow the steps below.
STEP 1 Make sure the batteries work fine. Replace them when needed. STEP 2 Plug the power cord to the power source. STEP 3 Press and hold head lift and foot lift simultaneously, then press and hold the button on the cord of control box for 3 seconds until you hear 2 beeps sound, the remote is then paired. Pairing Button Synchronizing Two Bases STEP 1 Plug A and B bases into power source.
STEP 2 Make sure remote A was already paired to Base A and remote B was paired to Base B. If not, please pair them separately by above-mentioned pairing remote instructions. STEP 3 Pair remote A to Base B, then base A and base B can be simultaneously operated by remote A. Base A Base B Pairing Remote A STEP 4 For HU10061 press and hold the Head Down and Foot Down buttons simultaneously for 5 seconds on remote B. The remote flashlight will turn on.
Headboard Bracket Installation Guide Headboard brackets are optional accessories and are not included. A 1/2" (13 mm) socket and 1/2" (13 mm) crescent wrench are necessary to complete installation. HEADBOARD BRACKET COMPONENTS (2) Headboard Brackets (2) T-Brackets (12) Short Bolts (12) Nuts STEP 1 The headboard bracket will have 2 long slots to accomodate any frame type. Align the appropriate slots on the bracket with the holes on the bed. Use bolts and nuts to secure the bracket.
STEP 2 To put the T-Bracket and Headboard Bracket together, you will need (2) bolts and (2) nuts. Slip the bolts through the holes from T-Bracket to Headboard Bracket with the head of bolt facing outward. Use 1/2" (13mm) socket and 1/2" (13mm) wrench to tighten the bolts. STEP 3 You may now connect your headboard to the attachment plates using the remaining bolts and nuts to secure it to the brackets. The heads of the bolts will face outward.
Troubleshooting In the event that the power foundation fails to operate, assess the symptoms and possible solutions provided in the chart below. SYMPTOMS Remote control illuminates and appears to be operable, but will not activate bed. SOLUTIONS Verify that the power cord is plugged into a working, grounded electrical outlet. Test the outlet by plugging in another working appliance.
SYMPTOMS SOLUTIONS Check batteries in wireless remote control, replace with two (2) new AAA batteries if necessary. Head & Foot lift function has minor interference during operation. Make sure that you are following the duty cycle of the motors (do not operate more than two minutes over an 18-minute period, or approximately 10% duty cycle. Press the lift buttons squarely and accurately. wireless remote control may be experiencing common Radio Frequency Interference from other radio transmitting devices.
Welcome to visit our website and purchase our quality products! With your inspiring rating, COSTWAY will be more consistent to offer you EASY SHOPPING EXPERIENCE, GOOD PRODUCTS and EFFICIENT SERVICE! US office: Fontana, California UK office: Ipswich Reward Points Exclusive Customer Service Personalized Recommenda�ons Permanent Shopping Cart Order History We would like to extend our hear�elt thanks to all of our customers for taking �me to assemble this product and giving us valuable feedbacks.