Everon™ 6200 Specification Sheet Corning® Everon™ 6200 is a digital transport platform supporting cellular and public safety technologies on fiber optic cable using the CPRI (non-packetized) protocol. The digital radio supports 8 x 3GPP bands with a combined EiRP value of almost 1 watt utilizing integrated antennas for cellular and Bluetooth beaconing, and backhaul connectivity for noncellular technologies. This platform is capable of supporting 5G technology from 360 MHz to 3.
E62-A2 – Access Unit Chassis The E62-A2 – Access Unit Chassis is a standard 19-inch 1U rack-mounted shelf, which serves as the host for Everon™ 6200. The E62-A2 provides coupling access to radio signal sources of multioperator, multisystem, and multiband, forming digital optical signals and distributing static capacity distribution to fiber-connected slave devices. One A2 supports up to eight optical interfaces connected to EUs (Expansion Units) or RUs (Radio Units).
The E62-E2-O – Expansion Unit is a standard 19-inch 1U rack-mounted shelf, which serves as the interface between the Master A2 and the Remote Unit. The E62-E2-O provides IP backhaul connection to all RUs, enabling Wi-Fi integration and other Gigabit Ethernet services deployed in a HetNet environment. The EU-O is the unit to expand the system. E62-N2RU – Low-Power Remote Unit The E62-N2RU is a low-power remote unit supporting cellular technologies on fiber optic cable using the CPRI protocol.
E62-HPRU – High-Power Remote Unit The E62-HPRU is a high-power remote unit supporting cellular technologies on fiber optic cable using the CPRI protocol. The HP is ideal for multioperator multiband, static capacity distribution deployments of cellular services in large coverage areas. The HP supports up to 43 dBm output per band in single 2T2R or dual 1T1R up to 80 MHz per band.
System Topology BTS RRU CPOI A2 E2 RU HPRU/H2RU/H2-7 2*20W M2RU 4*5W N2RU 8*0.
Specifications E62-A2 – Access Unit Chassis Supported Bands Band 3GPP Band Downlink Uplink Max Bandwidth 600 MHz 71 617-652 663-698 35 700 MHz Lower 12 729-746 699-716 17 700 MHz Upper 13 746-756 777-787 10 700 MHz Safety 14 758-768 788-798 10 800 MHz 20 791-821 832-862 30 850 MHz 5 869-894 824-849 25 850E MHz 26 859-894 814-849 35 900 MHz 8 925-960 880-915 35 1900 MHz 25 1930-1995 1850-1915 65 2100 MHz 66 2110-2180 1710-1780 70 2300 MHz 30 2350-2360
Electrical Electromagnetic Compatibility/Interference (EMC/EMI) 3GPP TS36.113 | 3GPP TS25.
Maintenance Interface Ethernet RJ45 / Wi-Fi / USB Electrical Electromagnetic Compatibility/Interference (EMC/EMI) 3GPP TS36.113 | 3GPP TS25.
E62-N2RU – Low-Power Remote Unit System Maximum RF Bands per Access Unit 4 Maximum RF Bands per Remote Unit 8 Maximum RF Bands per System 12 Maximum Access Units per System 3 (1 x Master / 2 x Slaves) Maximum EUs per Master AU 8 Maximum EUs cascaded 5 Maximum RUs cascaded 6 Frequency Range (Noncontiguous) 3700 MHz – 3800 MHz Bandwidth per Channel (Downlink & Uplink) ≤100 MHz (Contiguous) Digital Bandwidth per Channel (Downlink & Uplink) Bandwidth per System (Downlink & Uplink) 20 / 30 / 4
System Delay (AU+EU+RU) 8 µs Reverse Path (Uplink) Maximum Output Power per Band 20 dBm Output Power Accuracy ±2 dB Maximum Gain 20 ± 2 dB Maximum Input Power -25 dBm Ripple 4 dB Typical Manual Gain Control 30 dB @ 1 dB/step (AU:20 dB, RU:10 dB) System Delay (1AU+1EU+1RU) 8 µs Noise Figure 10 dB Typical @ Maximum Gain Interfaces Antenna Interface (All bands) QMA Female (External Antenna version) Access Unit RF Interface QMA Female Corning Optical Communications Everon™ 6200 Specificat
Transmission Connector Type SFP+, Standard LC Transmission Rate 10.1376 GB/s Optical Fiber Length 1.4 km / 10 km / 30 km 0.87 mi / 6.21 mi / 18.64 mi Physical Alarms DB9, Female (4x in, 4x out) Maintenance Interface Ethernet RJ45 / Wi-Fi / USB Electrical Electromagnetic Compatibility/Interference (EMC/EMI) 3GPP TS36.113 | 3GPP TS25.
E62-M2RU – Medium-Power Remote Unit System Maximum RF Bands per Access Unit 4 Maximum RF Channels per Remote Unit 4 Maximum Access Units per System 3 (1 x Master AU / 2 x Slaves AU) Maximum EUs per Master AU 8 Maximum EUs cascaded 5 Maximum RUs cascaded 6 Frequency Range (NonContiguous) 600 MHz – 3700 MHz Bandwidth per Channel (Downlink & Uplink) ≤ 100 MHz (Contiguous) Digital Bandwidth per Channel (Downlink & Uplink) Bandwidth per System (Downlink & Uplink) System Delay Adjustment Redundanc
Reverse Path (Uplink) Maximum Output Power per Band -13 dBm Maximum Gain 37 ± 2 dB Maximum Input Power -35 dBm Ripple 4 dB Typical Manual Gain Control 45 dB @ 1 dB/step (AU: 30 dB, RU: 15 dB) System Delay (AU+EU+RU) 8 µs Noise Figure 4 dB Typical @ Maximum Gain Supported Bands Band 3GPP Band Downlink Uplink Max Bandwidth 3600 MHz 48 3550-3700 3550-3700 100 2500 MHz TDD 41 2496-2690 2496-2690 100 1900 MHz 25 1930-1995 1850-1915 65 2100 MHz AWS 66E 2110-2200 1710-1780 90
Maximum Power Consumption (AU/EU/RU) 150 W AC Power 100-240 VAC, 50/60 Hz DC Power 48 VDC ± 20% Environmental Mean Time Between Failure (MTBF) > 100,000 hours Operating Temperature (RU) -40°C to +55°C / -40°F to +131°F Humidity 5% to 100% (Noncondensing) Cooling Passive Installation Wall or Pole Ingress Protection Rating IP67 (Outdoor) Complies with EN 300019-1-1, EN 300019-1-2, EN 300019-1-4 Mechanical RU(M2RU) (Width / Height / Depth / Weight) 360 mm / 115 mm / 260 mm / 12.0 kg (14.
Digital Bandwidth per Channel (Downlink & Uplink) 20 / 30 / 40 / 60 / 80 MHz Bandwidth per System (Downlink & Uplink) ≤ 280 MHz (in each direction) MIMO 2x2: 1 x RU | 4x4: 2 x RU | 8x8: 4 x RU IP Transmission Rate per RU 1 GB/s Maximum IP Connections per EU 6 Maximum IP Connections per RU 1 System Delay Adjustment Up to 80.
Noise Figure 4 dB Typical @ Maximum Gain Supported Bands Band 3GPP Band Downlink Uplink Max Bandwidth 600 MHz 71 617-652 663-698 35 850 MHz Extended 26 859-894 814-849 35 1900 MHz 25 1930-1995 1850-1915 65 2100 MHz AWS 66 2110-2180 1710-1780 70 2300 MHz 30 2350-2360 2305-2315 10 2500 MHz TDD 41 (Lower) 2496-2576 2496-2576 80 2500 MHz TDD 41 (Upper) 2610-2690 2610-2690 80 Interfaces Antenna Interface (All bands) 4.
Operating Temperature -40°C to +50°C / -40°F to +122°F Storage Temperature -40°C to +70°C / -40°F to +158°F Humidity 5% to 85% (Noncondensing) Cooling Passive Installation RU: Wall or Pole Ingress Protection Rating IP65 (Outdoor) Mechanical RU (Width / Height / Depth / Weight) excluding Bands 12, 13 & 14 400 mm / 125 mm / 300 mm / 16.0 kg 15.75 in / 4.92 in / 11.81 in / 35.27 lb RU (Width / Height / Depth / Weight) for Bands 12, 13 & 14 400 mm / 135 mm / 300 mm / 18.0 kg 15.75 in / 5.
Ordering guide Part Number Description Access Unit Chassis E62-A2-4-AC Access Unit Chassis, 4 Bands, 360 – 3800 MHz supported, 100-240 VAC Powered E62-A2-4-DC Access Unit Chassis, 4 Bands, 360 – 3800 MHz supported, ±48v DC Powered E62-AU-4-AC Access Unit Chassis, 4 Bands, 600 – 2700 MHz supported, AC Powered E62-AU-4-DC Access Unit Chassis, 4 Bands, 600 – 2700 MHz supported, DC Powered Access Unit Modules E62-AU-AC-M600 Access Unit Module, 4 Way Active Combiner 600 MHz (UL 663-698 / DL 617-652)
E62-N2RU-I-8-DC Indoor Nano Remote Chassis, 400 MHz, 8 Bands.
E62-M2RU-OD-M2100A Outdoor Mid-Power Remote Unit PA Module, 2100 MHz AWS (UL 1710-1780 / DL 2110-2200), 2T2R E62-M2RU-OD-M2500T Outdoor Mid-Power Remote Unit PA Module, 2500 MHz TDD (UL/DL 2496-2690), 2T2R E62-M2RU-OD-M3600T Outdoor Mid-Power Remote Unit PA Module, 3600 MHz TDD (UL/DL 3550-3700), 2T2R E62-M2-1717-1919-1 E62-M2, 2x2 (AWS, PCS), 10 km BiDi SFP E62-M2-1717-2525-1 E62-M2, 2x2 (AWS, TDD 2500), 10 km BiDi SFP E62-M2-1919-2525-1 E62-M2, 2x2 (PCS, TDD 2500), 10km BiDi SFP E62-M2-2525-25
E62-H2RU-OD-M2100A Outdoor High-Power Remote Unit Module, 2100 MHz (UL 1710-1780 / DL 21102200) E62-H2RU-OD-M2500TL Outdoor High-Power Remote Unit Module, 2500 MHz TDD Lower (2496-2596) E62- H2RU-OD-M2500TU Outdoor High-Power Remote Unit Module, 2500 MHz TDD Upper (2590-2690) E62-HP-AC-17-19-1 E62-HP, AWS, PCS, 10 km BiDi SFP, AC E62-HP-DC-17-19-1 E62-HP, AWS, PCS, 10 km BiDi SFP, E62-H2-AC-25-25-1 E62-H2, 2500 TDD, 10 km BiDi SFP, AC E62-H2-DC-25-25-1 E62-H2, 2500 TDD, 10 km BiDi SFP, DC This
Corning Optical Communications LLC • 4200 Corning Place • Charlotte, NC 28216 USA 800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/opcomm Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks.