Minimum Load (with neutral)
All load types 1W
Minimum Load (without neutral)
Incandescent (Tungsten) 7W
Halogen 7W
Fluorescent* N/A
Compact Fluorescent (CFL)* N/A
LED* N/A
Environmental
Operational Temperature 32˚ F - 104˚ F (0˚ C - 40˚ C)
All load ratings are based on an ambient
temperature of 25˚ C.
Humidity 5% to 95% non-condensing
Storage -4˚ F - 158˚ F (-20˚ C - 70˚ C)
Miscellaneous
Control Communications ZigBee, IEEE 802.15.4, 2.4 GHz, 15-channel
spread spectrum radio
Wallbox Volume 5.75 cubic inches
Weight 0.12 lb. (0.05 kg)
Shipping Weight 0.18 lb. (0.08 kg)
* NOTES:
(1) The maximum load requirements for fluorescent, CFL and LED loads
can vary greatly depending upon the specific fixture and/or bulb being
used. These load types have significant in-rush current which can trip the
protection circuitry on the device.
(2) The quality and performance of these load types varies greatly
from manufacturer to manufacturer. When using these load types, we
recommend testing in advance. If problems are found, simply changing to
a dierent bulb manufacturer may solve the problem.
(3) Additionally, we do not recommend the use of fluorescent, CFL, or
LED loads without a neutral wire connected to the dimmer due to the
capacitive nature of these load types.
Warnings and Considerations
WARNING! Turn OFF electrical power before installing or servicing this
product. Improper use or installation can cause SERIOUS INJURY, DEATH
or LOSS/DAMAGE OF PROPERTY.
ATTENTION! Coupez l’alimentation électrique avant d’installer ou de
réparer ce produit. Une mauvaise installation ou utilisation peut entraîner
des blessures graves, décès ou perte / dommages à la propriété.
WARNING! This device must be protected by a circuit breaker (20A max).
ATTENTION! Cet appareil doit être protégé par un disjoncteur (20A max.)
WARNING! Ground this device in accordance with the National Electric
Code (NEC) requirements. DO NOT rely solely upon the yoke plate’s
contact with a metal wallbox for adequate grounding. Use the device’s
ground wire to make a secure connection to the safety ground of the
electrical system.
ATTENTION! Cet appareil doit être en conformité avec le Code national
de l’électricité (NEC). Ne comptez pas uniquement au contact de la
plaque avant avec un boîtier mural métallique pour la mise à la terre
adéquate. Utilisez cet appareil à la terre de l’appareil pour établir une
connexion sécurisée au système électrique.
IMPORTANT! This device must be installed by a licensed electrician in
accordance with all national and local electrical codes.
IMPORTANT! If you are unsure about any part of these instructions,
consult a qualified electrician.
Supported Models
• C4-APD120 Adaptive Phase Dimmer, 120V
• C4-APD277 Adaptive Phase Dimmer, 277V
Introduction
The Control4® Adaptive Phase Dimmer operates independently or as part of a
Control4 home automation system. It installs in a standard back box using typical
wiring standards and communicates to the Control4 system using a wireless
connection.
Box Contents
• Adaptive Phase Dimmer
• Wire Nuts
• Warranty Card
• AdaptivePhaseDimmerInstallationGuide (this document)
Specifications and Supported Load Types
The specifications are described below.
Model Numbers C4-APD120-xx, C4-APD277-xx
Power Requirements C4-APD120: 120VAC +/-10%, 50/60Hz
C4-APD277: 277VAC +/-10%, 50/60Hz
This device can function with or without a
neutral AC connection depending on load
type. See load types and “Sample Wiring
Configurations” below.
Power Consumption C4-APD120: 450mW; C4-APD277: 550mW
Load Types and Ratings
Supported Load Types Incandescent; Halogen; Electronic (Solid State)
Low Voltage (ELV) transformers, Magnetic
(Iron Core, Inductive) Low Voltage (MLV)
transformers; Phase-Dimmable Fluorescents,
Compact Fluorescents, and LEDs.
C4-APD120 Maximum Load 1 Gang 2 Gang 3+ Gang
Incandescent (Tungsten) 600W 550W 500W
Halogen 600W 550W 500W
Fluorescent* 300W 300W 300W
Compact Fluorescent (CFL)* 300W 300W 300W
LED* 120W 120W 120W
C4-APD277 Maximum Load 1 Gang 2 Gang 3+ Gang
Incandescent (Tungsten) 1000 900 800
Halogen 1000 900 800
Fluorescent* 500 500 500
Compact Fluorescent (CFL)* 500 500 500
LED* 200 200 200
Adaptive Phase
Dimmer
Installation Guide
IMPORTANT! Use this device only with copper or copper-clad wire. Do
not use aluminum wiring. This product has not been approved for use with
aluminum wiring.
IMPORTANT! To reduce the risk of overheating and possible damage
to other equipment, do not install to control a receptacle or a motor
operated appliance.
IMPORTANT! This product generates heat during normal operation.
IMPORTANT! Using this product in a manner other than outlined in this
document voids your warranty. Further, Control4 is NOT liable for any
damage incurred with the misuse of this product. See “Troubleshooting.
IMPORTANT! Do NOT use a power screwdriver to install this device. If you
do, you may overtighten the screws and strip them. Also, overtightening
the screws may interfere with proper button operation.
IMPORTANT! This is an electronic device with intricate components.
Handle and install with care!
Installation Instructions
1 Ensure that the location and intended use meet the following criteria:
• Do not exceed the load capacity requirements of the dimmer. In multi-
gang installations, a reduction of the dimmers’ capacity is required to allow
the dimmers to be installed side-by-side. Refer to the load ratings in the
specifications above for details.
• Install in accordance with all national and local electrical codes.
• The range and performance of the wireless control system is highly
dependent on the following: (1) distance between devices; (2) layout of the
home; (3) walls separating devices; and (4) electrical equipment located near
devices.
2 If installing in a multi-gang scenario, use pliers to remove the inner-side
breakaway tabs. Bend each tab forward first, and then back and forth until
it breaks o. Remove the inner-side tabs ONLY on any device side that will
be adjacent to another device. DO NOT remove tabs on any side that will
become the outer side of a group of devices. Handle the device with care
after removing the tabs, as the broken edge can be sharp.
3 Turn o the local electrical power by either switching o the circuit breaker or
removing the fuse from the fuse box. To ensure the wires do NOT have power
running to them, use an inductive voltage detector.
NOTE: The back box wiring shown in this document is an example. Your
wire colors and functions may dier. If you are not sure which wires
are the Hot, Neutral, Load, Traveler, and Ground wires, have a trained
electrician perform the installation.
4 Prepare each wire. Wire insulation should be stripped back 5/8 of an inch
from the wire end (see Figure 1).
Figure 1. Strip Wire Insulation
5 Identify your wiring application, and then see the appropriate wiring diagram
in the “Sample Wiring Configurations” section below.
IMPORTANT! Not grounding this product, as described in the “Warnings
and Considerations” section, may result in an installation less immune to
damage caused by electrical disturbances, such as ESD or lightning, and
may void the warranty.
6 Identify and connect the dimmer wires to the back box wires using the wire
nuts.
IMPORTANT! The yellow wire is not a traditional traveler. It cannot directly
power a lighting load. It must be used only to connect to a Control4
Auxiliary Keypad. See “Sample Wiring Configurations.
TIP: If you are using a Control4 push-on (screwless) faceplate in a multi-
gang installation, attach the black faceplate subplate to all of the devices
that will be installed into the back box prior to attaching the devices to
the back box. This will help ensure that all the devices are properly aligned
and on the same plane after installation.
7 Fit the wires into the back box. Bend the wires in a zigzag pattern so that
they easily fold into the back box (Figure 2).
Figure 2. Bend the Wires
8 Align the dimmer to the back box (the load rating label should be at the
bottom) and fasten it with screws. Tighten the screws until the back side of
the yoke plate is even with the wall surface, but no further. Overtightening can
warp the dimmer and cause mechanical malfunction.
9 Install the Control4 Faceplate following the instructions in the Faceplate
Installation Guide or attach a standard Decora-style faceplate.
10 Turn ON power at the circuit breaker or replace the fuse
from the fuse box.
Operation and Configuration
On initial power up, all status LEDs on the dimmer will illuminate green, indicating
that the device has power. To set up this dimmer for use with a Control4 system,
refer to the Composer Pro User Guide.
To operate this dimmer as a stand-alone device:
• Click the top button to turn the light on.
• Click the bottom button to turn the light o.
• Press and hold the top button to ramp the light up. Release the button at the
desired light level.
• Press and hold the bottom button to fade the light down. Release the button
at the desired light level.
Air Gap Switch
During routine lamp replacement, remove power from the lamp by engaging the
air gap mechanism.
1 To engage, press on the right side of the top actuator bar until the left side
pops out. All LEDs on the dimmer will turn o, and the dimmer will no longer
control the light when the air gap mechanism has been engaged.
2 To return power to the dimmer and lamp, press on the left side of the top
actuator bar until it snaps back into place.

Summary of content (22 pages)