Condeco Sense User Manual PN41831 Version 1.
Contents Operational Description ............................................................................................................................ 3 Primary Function ................................................................................................................................... 3 Block Diagram ........................................................................................................................................ 3 Sensor Registration ............................
Operational Description The sensor contains a passive infra-red sensor and a wireless transmitter on 2.4 GHz IEEE 802.15.4. The device is battery powered using a 9Volt PP3 battery. The device can also be powered using a micro usb connection and a low voltage power supply.
Sensor Registration 1. Ensure the sensor is powered using a 9V battery. 2. Ensure that the sensor is within range of the gateway sensor. 3. Using the end if a paper clip or similar tool, activate the registration switch to register the sensor onto the network. When depressed the LED’s will illuminate and an entry will appear in the gateway software table view as described in step 11 of the software installation section.
FCC ID: 2ACMLPN41831 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.