User's Manual

RCBHC
VARIABLE FLAME REMOTE CONTROL
INSTALLATION AND OPERATING INSTRUC-
TIONS FOR
CONCENTRIC VARITAP, LATCHTAP
AND MAXTROL VALVES
This remote control system provides a safe, reliable, and user-
friendly remote control for Concentric Varitap, latchtap and max-
itrol valve gas appliances. The system can be manually turned
On/Off or can remotely control the flame adjustment. Always
check with the home owners manual of the appliance for addi-
tional information, or warnings regarding accessory installation
before connecting this remote control system.
Carefully inspect the contents for shipping damage. If any parts
are missing or damaged, immediately contact the dealer from
whom you purchased the kit. Do not attempt to install any part of
the kit unless all parts are in good condition. Please keep this
booklet for future reference.
CONTENTS OF KIT
Description Qty
Transmitter 1
Battery Alkaline AAA ( for Transmitter) 3
Receiver (Assembly) consists of : 1
Receiver Box
Battery Door Black
Slide Button-Black (On/RS/Off) 1
Battery Alkaline AA (for Receiver) 4
Velcro (Loop and Hook) 1
Plug-In Wiring Assembly – 22” Inches 1
Installation Instructions 1
FEATURES/SPECIFICATIONS
Battery Powered Transmitter and Receiver
Easy Access Front Battery Door
Pre-Programmed for Quick Installation
16 Security Codes
Optional 6 hour shutdown
• Quick Disconnect Wiring Assembly
WARNING
Important Safety Information
Read this manual thoroughly prior to installing, programming
or operating this remote control system.
This remote control system is designed for use with a
Concentric varitap, latchtap and maxtrol gas valve system.
Do not use this remote control system on appliances with
other types of gas valve.
This remote control system requires three (3) “AAA” and four
(4) “AA” alkaline batteries to power the transmitter and
receiver respectively. Wiring must conform to appliance
requirement and building codes/ordinances as required by
local and national code authorities having jurisdiction in your
area.
This remote control system should only be used as described
in this manual and any other use is not recommended and will
void the warranty.
Turn appliance OFF and allow to cool before
installing or servicing. DO NOT connect
110-120 VAC wiring to the gas control valve. The
remote control system must be installed exactly as
outlined in these instructions. Read all
instructions completely before attempting
installation and follow instructions carefully
during installation. Any modification of
components or failure to follow instructions
exactly will void the warranty and may cause a
fire hazard.
INSTALLATIONS
Remote Receiver:
The remote receiver may be wall mounted or installed in the appli-
ance per the appliance homeowners manual. Refer to the
Homeowner’s Manual for special installation instructions.
Failure to follow the installation instructions found in the appro-
priate Homeowners Manual will void the warranty and may cause
a fire hazard.
Installing Batteries:
The remote receiver uses four (4) “AA”- size batteries. To install
batteries,
1.Open the battery door by
pressing the two tabs located
on the door.
2.Install the batteries as
indicated on the receiver door.
3.Gently, close the battery door
until the door tab snaps in
place.
4.Install the receiver into the
appliance, refer to the
Homeowners Manual of
appliance for installation
instructions.
5.The batteries should be
replaced at least once every 6
months or when the battery
indicator light flashes, slowly
and periodically red.
Installing Wire:
This system comes with an 22 inch pre-assembled wire assembly.
Insert the four-pin black terminal wire into the back of the receiv-
er. The terminal wire block can only be installed one way and do
not force the terminal plug into the receiver.
Follow the homeowners manual for connecting the two (2) 1/4”
female spade terminals to the gas valve. Make sure that the color
of valve wires matches the color tag of the wiring from receiver,
exception with the Concentric latchtap wires are reversed in color.
Please refer to the following diagram for wiring directions.
If valve operates in reverse direction, simply reverse the wires and
valve should operate correctly.
For applications longer than 22 inches, use 18 gauge wire, 105ºC
rated, with no splices by using the approiate connectors. Connect
to the two (2) 1/4“ female spade wiring terminals and wire can be
no longer than 20 feet.
Make sure that the wires do not contact the
appliances any place other than at the terminals.
Exposure to temperatures higher than 105ºC
(250ºF) may cause the receiver to malfunction
and/or cause a fire hazard..
If you connect wires wrong, the valve will operate
in the wrong direction.
For Latchtap valve only. Wires are reversed in
color. The tagged red wire must be connected to
the black wire from the valve.
Remote Transmitter
Installing Batteries:
The remote transmitter uses three (3) “AAA”- size batteries. To
install batteries,
1.Press down the battery door tab
and pull out to remove the
battery door.
2.Install the batteries as indicated
in the battery compartment.
3.Gently, close the battery door
by snapping in place.
4.The batteries should be
replaced at least once every 6
months or when the battery
indicator is displayed on LCD
screen.
Setting Privacy (DIP) Switch on Receiver and Transmitter:
The remote receiver and transmitter privacy (DIP) switches are
preset at the factory. In the event of activation or interference
from other nearby transmissions, reset the code using the follow-
ing procedure:
1.Remove battery cover door from transmitter & pry up small
rectangle on top of receiver to view DIP switches.
2.Slide the DIP switches on the transmitter and receiver to your
choice of ON or OFF position. Switches #1, #2, #3 and #4 are
preset to “ON” for both the transmitter and receiver.
3.The switches on the transmitter and receiver must match exactly
in order for the system to work.
4.The system is now ready to operate.
See Optional Auto Shutdown.
WARNING
WARNING
NOTE
NOTE
Back of the Transmitter
Battery
Door
Ta b
ON
DIP
DIPON
Concentric
VaritapValve
Concentric
LatchtapValve
Maxitol Valve

Summary of content (2 pages)