COMPROD COMMUNICATIONS LTD. Customer Instruction Manual Model # BDA-806870 800 MHz BIDIRECTIONAL AMPLIFIER Technical manual 2015, Comprod Communications LTD. 88 Industriel Blvd Boucherville, QC, J4B 2X2 Phone 1.800.641.1454 • Fax 1.800.641.4616 3405 N. Benzing Road Orchard Park, NY, USA 14127 Phone 1.800.603.1454 • Fax 1.800.554.
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L M A N U A L IMPORTANT: The integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Subpart B – Unintentional Radiators. Final product must comply with unintentional radiators before declaring compliance of their final product to Part 15 of the FCC Rules and Industry Canada ICES-003.
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L M A N U A L Based on the philosophy of Anytime, Anywhere, and Anyplace, the amplifier module 806-869 MHz is designed for ease of use and being adaptable to various needs in the field. Recently developed technologies are applied and with the use of modern integrated circuits and RF components, the Comprod design ensures constant performances and reliable amplifier unit.
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L 18 Alarm (Led Indicator) AGC Alarm, S/D Alarm 19 Voltage(Current) +28V(3A)/+6V(3A) 20 In/Out Connector N (F) 21 Size (in) 22 Operating Temp./Humi. M A N U A L Alarm: High, Normal Low 10H x 16W x 8.5D -10 ~ +50℃/95% Block Diagram Details - The 800 MHz Amplifier module contains a (Low Noise Amplifier) LNA designed to detected very week signal.
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R AGC ATT Clk,Data,En Donor Antenna (Base) MGC ATT 10,20,.. T E C H N I C A L M A N U A L MGC ATT 1,2,3,.. LNA DAS Service Antenna (Mobile) HPA Det Sub B’d Card Power Supply (PSU) DC AC Det Down Link Path Monitoring & Control Unit LED Alarms MGC USB (Optional) RS 232 DPLX DPLX Det UP Link Path LNA HPA 1,2,3,.. MGC ATT 10,20, Clk,Data,En ..
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L o o 6 M A N U A L
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L M A N U A L . Monitoring and Control -. The monitoring and control Function is possible by connecting the BDA through a serial RS232 connector. A Serial to USB cable is available under request. The software designed for this purpose is provided (ver 1.02). this software should be installed on computer with windowas, xp,vista,7, 8 or 10 version, when execute the software we see the screen below.
0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L M A N U A L Automatic attenuation delivered by the AGC to maintain the output level constant When this value shows 0 it’s because the input power is lower than -53 dBm. If it’s zero in the Downlink path the AGC Alarm turn red. 5) DC voltage / current monitor It shows the DC voltage and current to the RF unit 6) System temp. 4.
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L M A N U A L Unpacking 1) The 800 MHz BDA should be unpacked soon after delivery and carefully inspected for possible shipping damage. It is the customer’s responsibility to file claims with the freight carrier if damage is suspected and is usually limited to a certain time period after delivery. 2) Carefully compare the packing slip(s) against the package contents to verify the receipt of all expected items.
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L M A N U A L BDA INSTALLATION DO NOT APPLY A.C. POWER TO THE BDA UNTIL CABLES ARE CONNECTED TO BOTH PORTS OF THE BDA AND THE ANTENNAS. 1. Mount the BDA on the wall with the RF connectors pointing DOWN. Using appropriate screws and anchors, attach the BDA to the wall at the four mounting holes on the side flanges. 2.
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L LabelingInstruction Figure 4: 800 MHz Bidirectional Amplifier 11 M A N U A L
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L M A N U A L Figure 5: Label position on the BDA The amplifier unit has its FCC/IC, Warning and Signal Booster Class B labels on the front cover, as shown in the above picture. These labels must not be removed.
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L M A N U A L If the amplifiers units are installed in a host device where this label is not visible, the host device should have visible label with the following text: BDA806870: Contains FCC ID: WDM-BDA806870 Model: BDA806870 IC: 7755A-BDA806870 HVIN: BDA806870 FVIN: BDA RF GUI V1.
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L Figure 6: Labels on BDA.
8 0 0 M H Z B I D I R E C T I O N A L A M P L I F I E R T E C H N I C A L M A N U A L WarningsandNotices WARNING: Changes or modifications not expressly approved by Comprod Communications could void the user’s authority to operate the equipment WARNING: To satisfy RF exposure requirement FCC: The RF exposure safe separation distance is 20cm IC: The RF exposure safe separation distance is 21.