EN TECHNICAL MANUAL 1 2 ABC DEF 4 5 3 GHI 6 JKL MNO PQRS 7 8 9 TUV WXYZ X 0 A B C D E F Digital call module Art. 3360B/3360BM .
Table of contents General description Self-testing Setting the language Setting the type of remote connection Use 1. Calling a user 2. Finding a name in the directory 3. Activating the door opening relay by entering the password code Accessing the programming mode Name directory 1. Entering names in the directory 2. Changing a name or a code in the directory 3. Deleting a name in the directory 4. Clearing the directory Access Control 1. Changing the default supercode (778899) 2.
General description The Comelit digital call module Art. 3360B can be used in Simplebus, Simplebus Top Building Kit and Vip systems, and is fitted with a name directory to store a list of names and passwords as well as an alphanumerical keypad to call users by entering their identification code.
Self-testing On power-up, the device carries out a diagnostic test of the connections to check the correct communication and configuration of the porter module (Art. 1622, 1622VC, 1621, 1621VC, 1682, 1682HVC, 4680C, 4681, 4682HC). The message PLEASE WAIT indicates self-testing in progress. On completion of self-testing, press the key to put the module in standby.
1B. or scroll through the directory using `` to exit, press 3. Activating the door opening relay by entering the password code MARIO ROSSI `` standby mode 1. press CODE: SCROLL 002 ENTER PASSWORD: CALL 2. to call, press 3. to exit, press OK 2. Finding a name in the directory CANC 2. enter the password code `` standby mode 1. press ENTER PASSWORD: ENTER PART OF THE NAME REQUIRED ****** 2.
Accessing the programming mode 3. press 1A. connect terminal PRG to GND and power up the module 1B. or press and enter the default supercode 778899 or to confirm 4. enter the name using the alphanumeric keypad, for the use of special characters see table on page 3 MARIO ROSS_ ENTER PASSWORD: *****9 OK ESC OK 2. press CANC CANC 5. to confirm, press 6. enter the code (max.
ENTER NAMES DELETE NAMES CHANGE NAMES CLEAR ALL NAMES MARIO ROSSI_ OK OK SCROLL CANC 3. press or OK OK SCROLL CANC 8. change the name using the alphanumeric keypad, for the use of special characters see table on page 3 9. press or to confirm to confirm 10. change the code (max. 3 digits) using the alphanumerical keypad ENTER PART OF THE NAME REQUIRED CODE: __2 4. enter the name using the alphanumeric keypad, for the use of special characters see table on page 3 M_ OK ESC 11.
3. press or 4. Clearing the directory to confirm 1. access programming mode, see page 6 2. select the menu items: Name directory ⇒ Clear all names ENTER PART OF THE NAME REQUIRED ENTER NAMES DELETE NAMES CHANGE NAMES CLEAR ALL NAMES 4. enter the name using the alphanumeric keypad, for the use of special characters see table on page 3 OK OK SCROLL ESC 3. press M_ or to confirm DELETE ALL NAMES? SCROLL OK CANC 5. to confirm the first letter of the name, press 6.
2. Restoring the default supercode (778899) Access control 1. Changing the default supercode (778899) The supercode (778899 is the default code) is used to access the programming menus. 1. access programming mode, see page 6 2. select the menu items: Access control ⇒ Supercode ⇒ Enter new code 1. access programming mode, see page 6 2. select the menu items: Access control ⇒ Supercode ⇒ Default settings ENTER NEW CODE DEFAULT SETTINGS ENTER NEW CODE DEFAULT SETTINGS OK OK OK SCROLL 3.
3. press or to confirm DELETE PASSWORD: 4. enter the password (max. 6 characters consisting of numbers and/or letters from A to F) using the alphanumeric keypad _ 3ABC4 IMPORTANT: the password must be at least 4 characters long OK ESC ENTER PASSWORD: 5. press _ 3ABC4 CANC to confirm OK ESC 5. press CANC to confirm PASSWORD DELETED 6. to exit, press 5. Finding a password code 1. access programming mode, see page 6 2. select the menu items: Access control ⇒ Password ⇒ Search 6.
5. press to confirm 6. scroll through all the passwords using DELETION COMPLETE 3ABC4 SCROLL ESC Settings of the directory module (Art. 3360B) 6. Erasing all passwords 1. access programming mode, see page 6 2. select the menu items: Access control ⇒ Password ⇒ Clear ENTER DELETE SEARCH CLEAR OK OK SCROLL 5. to exit, press ESC 1. Modifying the language setting 1. access programming mode, see page 6 2.
SELECT LANGUAGE ITALIANO *ENGLISH FRANCAIS OK TYPE OF DOWNLOAD OFF *USB RS485 OK SCROLL ESC OK OK SCROLL »» * indicates language selected 6. to exit, press »» * indicates the type of download selected 6. to exit, press 2. Setting the type of remote connection 3. Setting the second language CAUTION: For downloading in RS485 mode, see diagram on page 35 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ Type of download OK OK SCROLL 3. press or ESC to confirm 4.
5. press or 5. Setting call management to confirm It is necessary to set the type of system (Simplebus, Simplebus Top or ViP) and then the call mode (Standard, Indirect code, Immotec standard or Immotec indirect). SELECT LANGUAGE ITALIANO *ENGLISH FRANCAIS OK Type of system: OK SCROLL ESC »» * indicates language selected 6. to exit, press 4. Disabling the second language To cancel the second language function: 1A.
The call can be made in the following ways: `` standby mode 1A. enter the user code (e.g. 25 015) MARIO ROSSI CALL USER _25 015 CODE: SCROLL CALL CANC 025 015 CALL 2. to call, press 3. to exit, press 1B. or scroll through the directory using MARIO ROSSI CODE: SCROLL 025 015 CALL 2. to call, press 3.
CAUTION: to modify the type of system and the call mode it is necessary to erase the entire directory, see page 8. 1. set the selector on porter module Art. 1622, 1622VC, 1621, 1621VC, 4680C, 4681 to ON, see Fig. 2. connect the porter module to the terminal block CALL MANAGEMENT *STANDARD INDIRECT CODE IMMOTEC STANDARD OK 1622 4680C 1621 4681 OK SCROLL ESC 9. press or to confirm »» * indicates the selected call mode 10. set the selector on porter module Art.
8. Entering the welcome message NAME ONLY YES *NO This function is disabled by default. It is possible to enter the welcome message using software Art. 1249B. OK OK SCROLL ESC 4. select YES to enable the function, NO to disable it 5. press or to confirm »» * indicates active selection 7. Enabling/disabling the welcome message This function can be used to enter a welcome message (MAX 40 characters long, covering 4 lines in block capitals).
9. Enabling/disabling the static message This function is disabled by default. If activated, the welcome message will appear and remain on the display after a 30-second period of inactivity. 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ Welcome message ⇒ Static message 3. press or to confirm SCREEN SAVER YES *NO OK OK SCROLL CHANGE ENABLE STATIC MESSAGE ESC 4. select YES to enable the function, NO to disable it 5.
12. Changing keypad speed The "keypad speed" parameter determines the speed with which prolonged pressing of a key is converted into "multiple presses of the same key". The default keypad speed setting is high. 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ Keypad Speed WELCOME MESSAGE SCREEN SAVER KEYPAD SENS. KEYPAD SPEED OK 3. press or to confirm 4. select the desired keypad speed using KEYPAD SPEED LOW MEDIUM * HIGH OK SCROLL ESC 5. press or to confirm.
4. select YES to enable the function, NO to disable it 5. press or to confirm »» * indicates active selection 1. access programming mode, see page 6 2. select the menu item: Info PARAMETER CHANGED 15. Changing the RS485 address of the porter module 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ System parameters ⇒ RS485 address NAME DIRECTORY ACCESS CONTROL SETTINGS INFO OK OK SCROLL 3. press SPEAKER PARAMETERS RS485 ADDRESS OK 16.
Standard settings of the porter module (Art. 1622, 1621, 4680C, 4681) 7. press to confirm »» confirmation tone 1. Setting the porter module parameters (audio time, door lock time, reset time) PARAMETER CHANGED AUDIO TIME= 10 - 180 sec. DOOR LOCK TIME= 1 - 8 sec. RESET TIME= 1 - 10 sec. 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ System parameters ⇒ Speaker parameters SPEAKER PARAMETERS RS485 ADDRESS OK OK SCROLL 3. press or ESC to confirm 4.
Advanced settings of the porter module (Art. 1622, 1621, 4680C, 4681) 1B. Enabling/disabling the door confirmation tone on the porter module 1. Lock on SE This function is disabled by default. 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ System parameters ⇒ Speaker parameters ⇒ Advanced options ⇒ Lock on SE ⇒ Confirmation tone 1A. Setting the type of door lock on the SE output of the porter module The default lock type is in AC. 1. access programming mode, see page 6 2.
1C. Enabling/disabling the standby lock release on the porter module 1D. Viewing the parameters of the door lock on the SE output of the porter module This function is enabled by default. 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ System parameters ⇒ Speaker parameters ⇒ Advanced options ⇒ Lock on SE ⇒ Standby lock rel. 1. access programming mode, see page 6 2.
ACTUATOR FUNCTION YES *NO OK PARAMETER CHANGED OK SCROLL ESC 4. select YES to enable the function, NO to disable it 5. press or to confirm »» * indicates active selection »» confirmation tone 2B. Enabling/disabling the relay contact in parallel to the porter module SE output 1. access programming mode, see page 6 2.
2C. Viewing the relay contact parameters 3. S serial 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ System parameters ⇒ Speaker parameters ⇒ Advanced options ⇒ Relay contact ⇒View ACTUATOR FUNCTION IN PARALLEL TO SE VIEW OK 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ System parameters ⇒ Speaker parameters ⇒ Advanced options ⇒ S serial ⇒ Actuator function ACTUATOR FUNCTION OK SCROLL 3. press 3A.
4. Voice messages 5. Call 4A. Enabling/disabling voice and visual messages on the porter module 5A. Enabling/disabling triple call 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ System parameters ⇒ Speaker parameters ⇒ Advanced options ⇒ Voice messages This function is disabled by default. It is possible to enable or disable the triple call made by Art. 3360B to the internal units.
5B. Enabling/disabling the call confirmation tone 5C. Enabling/disabling the call codes booster This function is enabled by default. 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ System parameters ⇒ Speaker parameters ⇒ Advanced options ⇒ Call ⇒ Confirmation tone This function is disabled by default. Allows control of over 70 internal units connected to porter module. 1. access programming mode, see page 6 2.
5D. Setting the call answer wait time 5E. Viewing the porter module call parameters 1. access programming mode, see page 6 2. select the menu items: Settings ⇒ System parameters ⇒ Speaker parameters ⇒ Advanced options ⇒ Call ⇒ Answer wait time 1. access programming mode, see page 6 2.
SELF IGNITION *YES NO OK SCROLL VOICE MESSAGES CALL SELF IGNITION DEFAULT SETTINGS OK ESC 4. select YES to enable the function, NO to disable it 5. press or to confirm »» * indicates active selection »» confirmation tone PARAMETER CHANGED OK OK SCROLL 3. press or ESC to confirm DEFAULT SETTINGS YES *NO OK SCROLL OK ESC 4. select YES to enable the function, NO to disable it 5. press or to confirm 7.
3. Multidownload TYPE OF DOWNLOAD OFF *USB RS485 OK SCROLL OK ESC 4. the messages "Found new hardware Art. 3360B" and "New hardware installation wizard" appear on the PC 5. follow the instructions of the installation wizard through to completion CAUTION: select the Drivers folder located in the Art. 1249B installation folder. 2. Using the directory via software Art. 1249B CAUTION: connection to the PC is via USB; ensure that the drivers have been installed, see page 28. 1.
Menu diagram NAME DIRECTORY ENTER NAMES functions available in Simplebus, Simplebus TOP and ViP mode functions not available in ViP mode DELETE NAMES CHANGE NAMES ACCESS CONTROL CLEAR ALL NAMES DELETE ALL NAMES? SUPERCODE ENTER NEW CODE DEFAULT SETTINGS PASSWORD ENTER DELETE SEARCH CLEAR SETTINGS TYPE OF DOWNLOAD DELETE ALL PASSWORDS? OFF USB RS485 SYSTEM PARAMETERS SPEAKER PARAMETERS ENTER AUDIO TIME ENT.
SETTINGS SYSTEM PARAMETERS ADVANCED OPTIONS LOCK ON SE CONFIRMATION TONE YES NO STANDBY LOCK REL. YES NO VIEW RELAY CONTACT ACTUATOR FUNCTION YES ACTIVATION TIME NO IN PARALLEL TO SE YES NO VIEW S SERIAL ACTUATOR FUNCTION YES NO VOICE MESSAGES OFF ITALIANO FRANCAIS ESPANOL NEDERLANDS GREEK ENGLISH CALL ...
SETTINGS SETTINGS SPEAKER PARAMETERS ADVANCED OPTIONS CALL CONFIRMATION TONE YES NO CODES BOOSTER YES NO ANSWER WAIT TIME VIEW SELF IGNITION YES NO DEFAULT SETTINGS YES NO RS485 ADDRESS SELECT LANGUAGE ITALIANO ENGLISH FRANCAIS DEUTSCH PORTUGUES ...
SETTINGS SECOND LANGUAGE DEUTSCH PORTUGUES ... DEFAULT CALL MANAGEMENT SIMPLEBUS STANDARD INDIRECT CODE IMMOTEC STAND. IMMOTEC INDIRECT SIMPLEBUS TOP STANDARD INDIRECT CODE IMMOTEC STAND. IMMOTEC INDIRECT VIP STANDARD IMMOTEC STAND.
SETTINGS SCREEN SAVER YES NO KEYPAD SENS. LOW MEDIUM HIGH KEYPAD SPEED LOW MEDIUM HIGH KEYPAD TONE YES NO DEFAULT SETTINGS YES NO INFO FW REVISION NAMES STORED PASSWORDS ENTERED RS485 ADDRESS Table of Simplebus Top products Door-entry phones Switching devices Mixers Switchboards 34 IR. Art. 2608 IR. 006 / Art. 2610 IR. 008 / Art. 2619 IR. 000 Art. 2628 IR. 005 / Art. 2638 IR. 006 Art. 1424 IR. 002 Art. 4888C IR. 013 Art. 1998A IR. 006 / Art. 1998V IR. 001 / Art. 1998VC IR.