EN TECHNICAL MANUAL Digital directory module Art. 3072S Passion.Technology. Design.
Warning Intended use This Comelit product was designed for use in the creation of audio and video communication systems in residential, commercial or industrial settings and in public buildings or buildings used by the public. Installation All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
Description Vandalcom series digital directory module made using double 2.5 mm 316 stainless steel plate, complete with 4 backlit buttons and 32-character alphanumerical display. Stores up to 1000 user names. Name scrolling is carried out using 2 search buttons. One the right name has been found, just press the call button. For use in Building kit, SBTOP, SB1 audio, SB2 audio and ViP systems. 1. MR1 2. MR2 1. LCD screen 2.
Technical features MAIN FEATURES Backlighting color Vandal Resistant rating (IK code) Product height (mm) Product width (mm) Product depth (mm) Operating temperature (°C) Maximum current absorption (mA) SOFTWARE/FIRMWARE SPECIFICATIONS No.
Connections Connection to earth of 3072S To prevent any interference caused by electrostatic discharges, it is advisable to screen the casing as shown in the diagram Connection to computer COMPUTER USB ALIM.
Connection in Building Kit and SB2 systems 1210 - 1595 + 120-230 V SE SE - + J9 C O M G N D NC NO D O R T E V - V + L L 4681 1621VC J11 J1 V J2 V 12 12 S + - ~ ~ - P R - D D + - - R X T X V V 12 12 S + - ~ ~ - P R - D D + - - 3070S "V-" BLUE "S" YELLOW "V+" BROWN R T X X 3072S 2E7T000696 Use the cable 2E7T000696 supplied with Art. 3070S and Art. 3072S 20 m max. Local door-opener button.
Program and Operation The Comelit digital call module Art. 3072S can be used in Building kit, SBTOP, SB1 audio, SB2 audio and ViP systems and can be used to call a door-entry phone user by selecting his/her name from a list saved to the memory: The main characteristics are as follows: • Memory capacity 1400 names of 16 alphanumerical characters. • 32-character alphanumeric display.
Self-testing Call management testing When the device is switched on, it performs a test to check the type of system configured on the speaker (Simplebus, Simplebus Top or VIP).
Using the digital module Calling a user INITIAL CONDITION SELECT NAME BY h O i On power up in standby. SEARCH THE NAME BY PROCEDURE DISPLAY INFO DESCRIPTION Select the user by scrolling through the list of users Scroll through the list using keys JOHN DOE PRESS TO CALL or To scroll faster, press and hold one of the keys. OR: select the user by searching the directory to access the directory.
Ending a call/conversation INITIAL CONDITION CALL EFFECTED Call effected. Or: COMMUNICATING... PROCEDURE Press the key Conversation in progress. DISPLAY INFO DESCRIPTION END OF COMMUNICATION Accessing/exiting the configuration stage PROCEDURE DISPLAY INFO and power up the module. DESCRIPTION The module is in programming mode. Connect terminal PR to terminal – MAIN SETTINGS Scroll through the menu using Press Press or . to confirm. to return to the menu level above.
1. Settings 1.1. System parameters 1.1.1. Speaker Parameters This procedure can be used to: A. Change the audio time: audio times (t AUDIO) B. Change the door lock time: the door lock relay closure time (t DOOR LOCK) C. Change the reset time [NOT VIP]: the speaker module reset time once door-entry phone communication has ended (t RESET) PROCEDURE DISPLAY INFO DESCRIPTION MAIN SETTINGS Access configuration (see “Accessing/ exiting the configuration stage”) Select the menu SETTINGS / SYSTEM PARAM.
PLEASE WAIT AUDIO TIMING 0020 Scroll using h i DOOR LOCK TIME 0002 h i or RESET TIME 0010 Press above. to return to the menu level h i CALL MANAGEMENT SIMPLEBUS h i Exit configuration (see “Accessing/exiting the configuration stage”) 1.1.2. Download type [NOT VIP] The parameter sets the type of connection (RS232 or RS485) used for data management. PROCEDURE DISPLAY INFO MAIN SETTINGS Access configuration (see “Accessing/ exiting the configuration stage”) SETTINGS SYSTEM PARAM.
1.1.3. Call management There are 3 call management modes to choose from: • Standard Simplebus (default), • Simplebus Top, • Vip A. SIMPLEBUS - STANDARD call mode (default) In this operating mode, the door-entry phone user is identified by a Username field and a Code field no longer than 3 digits (between 1 and 240). Address entry on the speaker is managed using software 1249B. EXAMPLE: User name= Smith; Code= 1 B.
1.1.4. RS485 Address [NOT VIP] The value of this parameter is used only in special applications. PROCEDURE DISPLAY INFO MAIN SETTINGS Access configuration (see “Accessing/ exiting the configuration stage”) SETTINGS SYSTEM PARAM. Select the menu SETTINGS / SYSTEM PARAM. / ADDRESS RS485 SYSTEM PARAM. ADDRESS RS485 Enter the desired value using the keys. Press the or key to confirm. DESCRIPTION Scroll through the menu using Press Press above. or . to confirm.
1.3. Default settings This procedure restores the factory-set default parameters.
2. Info This procedure can be used to view: • the firmware version • the number of users stored [NOT VIP] • the RS485 address [NOT VIP] • call management PROCEDURE Access configuration (see “Accessing/ exiting the configuration stage”) Select the menu INFO DISPLAY INFO MAIN INFO DESCRIPTION Scroll through the menu using Press Press above. or . to confirm. to return to the menu level Art.3072/B 1.1 h i Scroll using Press the key to exit the menu.
Reading (upload) of the stored list Software Art.1249/B can be used to read the list, from module 3072S, with the Username and Code fields. The following preliminary procedures must be performed: INITIAL CONDITION Module powered up in standby mode. PROCEDURE SELECT NAME BY h i DISPLAY INFO Connect the cable supplied with software Art. 1249/B to terminals TX / RX / - (or D / D- if you have an RS485 line). SELECT NAME BY h i Run software Art. 1249/B.
2. Navigation tree MAIN SETTINGS SYSTEM PARAM. SPEAKER PARAM. ENTER t AUDIO ENT.
System performance and layouts For further information of system performance and to view installation layouts, click on the system type that best meets your requirements: • Building Kit audio/video system for the creation of audio-video systems for small apartment blocks. • SBTOP audio/video system for the creation of audio-video systems for residential complexes. • SB2 audio system for the creation of audio systems for residential complexes.
1ª edizione 01/2019 cod. 2G40002106 CERTIFIED MANAGEMENT SYSTEMS w w w.comelitgroup.