EN TECHNICAL MANUAL Audio/video module for SBTOP system Art. 4680C, 1622VC, 1622VCF Passion.Technology. Design.
Warning Intended use This Comelit product was designed for use in the creation of audio and video communication systems in residential, commercial or industrial settings and in public buildings or buildings used by the public. Installation All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
Description Article 4680C is a colour audio-video module which is compatible with Comelit “SBTOP” video entry systems, exclusively for use in conjunction with riser power supply unit Art. 4888C. It can be installed in Ikall, Ikall Metal, Vandalcom, Roma external units and can be finished with additional modules to meet all system requirements. Art.
. 1. 5. 6. 7. ON DIP ON OFF 2. 3. 10. 1. DIP switches for function programming and setting the user code. 4. Indicator LED: call sent. 2. Switch for confirming special programmes. 6. Microphone. 9. 8. 5. Loudspeaker. 3. Loudspeaker volume control. 7. Indicator LED: system busy. 8. Indicator LED: sound activated. 9. Colour camera (with Art. 4680C only). 10. Indicator LED: lock-release activated. Art. 1622VCF ON Art. 1622VC DIP ON ON ON OFF OFF DIP S V 11. 12. 13.
Technical characteristics Art. 4680C MAIN FEATURES Audio/video system Yes Horizontal resolution (TVL) 540 Minimum illumination (lux) 0.35 Lens size (mm) 3.
Art. 1622VC Art.
External unit installation 40-45 cm 163 cm 87° 130 cm 163 cm 130 cm 59° 1 The camera must not be installed in front of light sources, or in places where the filmed subject is against the light. In dim environments, we recommend additional lighting is provided. 2 3 4 Connect the module support frame to earth. 1 Art. 1622VC 3 1 5 Art.
SOLO MT COMPLETO BLUE OFF F F O LE D F F O LE D WHITE Nameplate LED lighting selection. 6 3 2 2 Alternative microphone position (excluding 4 module entrance panel).
Connections 4680C/1622VC/1622VCF connections - VIDEO ENTRY SYSTEM RISER 1595 + 120-230 V S E C O M NC NO G N D P D R O R T E V - V + L L 4680C 1622VC 1622VCF 20 m max. Local lock-release button. Active input closed for DOOR OPEN signal. Remote camera connection (Art.
Variants Variant for using a safety lock Variant for using the external unit relay 230 V S E C O M NC NO G N D P D R O R T E V - V + L L 12/24V AC/DC 12V/24V AC-DC 10A MAX 4680C 1622VC 1622VCF S E C O M NC NO “C.NC.NO relay activation on actuator command: 2 sec” G N D P D R O R T E V - V + L L 4680C 1622VC 1622VCF Set dip switches in permanent mode as shown in figure (Dip switch 8 ON, Dip switches 1,2,3,4,5,6,7 OFF) (Applies to Art. 4680C with R.I.
Module connection Ikall / Ikall Metal modules Connection of button modules 33433, 33434, 33436, 33433M, 33434M, 33436M 4680C 1622VC 1622VCF J1 J1 J2 J2 Connection of Art. 3348B, 3348BM - VIDEO ENTRY SYSTEM RISER 1595 + 120-230 V S E C O M NC NO G N D P D R O 4680C 1622VC 1622VCF R T E V - V + L L C NC NO C NC NO ~ 1 1 1 2 2 2 + J1 J1 J2 J2 ~ - AL + 3 3 3 6 7 8 9 - R C D D K K + - 3348B 3348BM Connection of Art.
Vandalcom modules Connection of Art. 3064S - VIDEO ENTRY SYSTEM RISER 1595 + 120-230 V J1 C O M S E NC NO G N D P D R O R T E V - V + L L J2 J1 J2 4680C + 3268S 1622VC / 1622VCF +3262S - S V + C J2 - S V C + J1 - S V C + CV3 3064S 3064S 1172B 3064S 1172B 1172B 3064S 1172B Use the cable supplied with Art. 3262S, 3268S Use bulb Art. 1172B for nameplate lighting. The bulb is polarised. Connection of Art.
Connection of Art. 3070S, 3072S - VIDEO ENTRY SYSTEM RISER 1595 + 120-230 V S E C O M NC NO G N D P D R O R T E 4680C 1622VC 1622VCF V - V + L L J1 V J2 V 12 12 S + - ~ ~ - P R D D - + - - R X T X V V 12 12 S + - ~ ~ 3070S "V-" BLUE "S" YELLOW "V+" BROWN - P R - D D + - - R T X X 3072S 2E7T000696 Use the cable 2E7T000696 supplied with Art. 3070S, Art. 3072S Modules for Single-plate external unit Connection of Art.
Button programming 33433 33434 33436 1 3 4 Set the user code using the dip switches; see addressing table.
Special programmes -V +V GND 1 2 3 PR 1 sec.
CODE DIP SWITCH ON FUCNTION De-misting heating element 213 1,3,5,7,8 212 3,5,7,8 OFF (default) ON Audio-visual messages 210 2,5,7,8 211 1,2,5,7,8 Swedish visual messages only 214 2,3,5,7,8 OFF (default) 215 1,2,3,5,7,8 Italian 216 4,5,7,8 French 217 1,4,5,7,8 Spanish 218 2,4,5,7,8 Dutch 219 1,2,4,5,7,8 Greek 220 3,4,5,7,8 English 221 1,3,4,5,7,8 German 222 2,3,4,5,7,8 Portuguese 202 2,4,7,8 203 1,2,4,7,8 Enables voice message (door opened warning) when the RTE co
234 2,4,6,7,8 235 1,2,4,6,7,8 236 3,4,6,7,8 Awaiting response time: 30 sec Talk time: 90 sec (default) Talk time: 180 sec 237 1,3,4,6,7,8 Self-ignition: enabled (default) 238 2,3,4,6,7,8 Self-ignition: disabled 239 1,2,3,4,6,7,8 240 5,6,7,8 243 1,2,5,6,7,8 244 3,5,6,7,8 208 5,7,8 209 1,5,7,8 249 1,4,5,6,7,8 Call transmission: single (default) 250 2,4,5,6,7,8 Call transmission: triple 241 1,5,6,7,8 Control of internal units connected to Art.
6ª edizione 05/2018 cod. 2G40002075 CERTIFIED MANAGEMENT SYSTEMS w w w.comelitgroup.