EN TECHNICAL MANUAL Technical manual for Ikall external unit Art. 4681 and power supply unit Art.
Warning • Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force. • All the equipment must only be used for the purpose it was designed for. Comelit Group S.p.A. does not assume responsibility for improper use of the apparatus, for modifications made by third parties for any reason or purpose, or for the use of non-original accessories and materials.
Description 1. ON DIP PR J11 CNF J9 ON OFF 2. 3. 4. 5. 6. 7. 8. 9. 1. S1 DIP switches for function programming and setting the user code. 2. PR switch for input/output programming. 3. J11 jumper for power supply management. Remove in case of power on V+ and V-. J9 jumper for power supply management. Remove in case of power on V+ and V-. 4. CNF switch for confirming special programmes. 5. CAUTION: connector reserved for the module 1621VC. 6. Loudspeaker volume control. 7. 8-pole cable connector.
1. 2. 3. 4. 42,5 cm 5. 7. 163 cm 130 cm 100° 6. 1. Signalling LED: call sent. 2. Speaker. 3. Microphone. 4. Signalling LED: system busy. 5. Colour camera. 6. Signalling LED: sound activated. 7. Signalling LED: lock release activated. External unit installation 1 +L -V -L A powered by Art. 1210 2 4 +L +V -L B powered by power supply unit Art.
If the total power consumption of the modules exceeds 100mA then it will be necessary to use the power supply unit Art. 1595. To calculate the power consumption values see “Consumption management” on page 13. COMPLETE MT ONLY 1 WHITE BLUE OFF F F O LE D F F O LE D 1 Nameplate LED lighting selection.
Button programming 33433 33434 33436 1 2 Set the user code using the dip switches; see the table on page 7.
Dip switch programming table Code Dip switch ON Name Code Dip switch ON Name Code Dip switch ON 1 1 50 2,5,6 99 1,2,6,7 2 2 51 1,2,5,6 100 3,6,7 3 1.2 52 3,5,6 101 1,3,6,7 4 3 53 1,3,5,6 102 2,3,6,7 5 1.3 54 2,3,5,6 103 1,2,3,6,7 6 2.3 55 1,2,3,5,6 104 4,6,7 7 1,2,3 56 4,5,6 105 1,4,6,7 8 4 57 1,4,5,6 106 2,4,6,7 9 1.4 58 2,4,5,6 107 1,2,4,6,7 10 2.4 59 1,2,4,5,6 108 3,4,6,7 11 1,2,4 60 3,4,5,6 109 1,3,4,6,7 12 3.
Code Dip switch ON Name Code Dip switch ON Code Dip switch ON 3,5,8 179 1,2,5,6,8 210 2,5,7,8 149 1,3,5,8 180 3,5,6,8 211 1,2,5,7,8 150 2,3,5,8 181 1,3,5,6,8 212 3,5,7,8 151 1,2,3,5,8 182 2,3,5,6,8 213 1,3,5,7,8 152 4,5,8 183 1,2,3,5,6.8 214 2,3,5,7,8 153 1,4,5,8 184 4,5,6,8 215 1,2,3,5,7.8 154 2,4,5,8 185 1,4,5,6,8 216 4,5,7,8 155 1,2,4,5,8 186 2,4,5,6,8 217 1,4,5,7,8 156 3,4,5,8 187 1,2,4,5,6.
Special programmes L L 1 2 3 4 5 6 Set the dip switches for the function you wish to program, see the table on page 10.
CODE DIP SWITCHES ON 213 212 1,3,5,7,8 3,5,7,8 FUNCTIONS De-misting heating element OFF (default) ON Audio-visal messages Hebrew Polish Catalan Galician Basque Danish Norwegian Swedish Italian French Spanish Dutch Greek English German Portuguese 195 196 197 198 199 206 207 211 215 216 217 218 219 220 221 222 1,2,7,8 3,7,8 1,3,7,8 2,3,7,8 1,2,3,7,8 2,3,4,7,8 1,2,3,4,7.8 1,2,5,7,8 1,2,3,5,7.8 4,5,7,8 1,4,5,7,8 2,4,5,7,8 1,2,4,5,7.8 3,4,5,7,8 1,3,4,5,7.8 2,3,4,5,7.
235 236 1,2,4,6,7.8 3,4,6,7,8 Talk time: 90 secs. (default) Talk time: 180 secs. 237 238 1,3,4,6,7.8 2,3,4,6,7.8 Self-ignition: enabled (default) Self-ignition: disabled 239 240 1,2,3,4,6,7,8 5,6,7,8 243 244 1,2,5,6,7.8 3,5,6,7,8 208 209 5,7,8 1,5,7,8 249 250 1,4,5,6,7.8 2,4,5,6,7.8 Call transmission: single (default) Call transmission: triple 0 255 1,2,3,4,5,6,7.8 System mode Simplebus (default) Simplebus Top (NO Art.
Power supply unit Art. 1210 Dopo un cortocircuito,per ripristinare l'apparecchio, interrompere l'alimentazione per circa 1 minuto. To reset the operation after a short circuit,cut off mains voltage for about 1 minute. Apres un court circuit, pour remettre en fonction l'appareil, interrompre l'alimentation pendant environs une minute. INPUT/D'ENTREE 110V-240V 1. 1. L 800mA 50-60Hz N L ta=40°C Ar t.1210 R C US 257258 OUTPUT/SORTIE 34V 1.2A 1'on/5'off 0.5A L1 L1 L2 L2 2. 3. 4.
Consumption management On systems with Art. 4681 and power supply unit Art. 1210, the maximum current available for the external unit modules is 100mA. Calculate the total power consumption of the modules in your system configuration using the Consumption table. If the total power consumption exceeds 100mA, connect a supplementary power supply unit (Art. 1595) to the V+ and V- contacts of the external unit, as shown in the figure below (see the diagram S2W/MOD) +L -V +L -L A powered by Art.
Operating distances with Art. 1210 B B H H 6601W 1216 1214/2C (MAX 3) 6721W 6700W 6701W 6701B 6700W 6701W 6701B 1216 1214/2C (MAX 4) (MAX 4) 6601W 1214/2C 6601W 1214/2C 6801W 1214/2C 6801W 1214/2C A 6721W A 1210 C 1210 D C 1212/B 4681 6601W 4681 6801W (MAX 1) Distances valid for articles: 6700W, 6701W, 6701B, 6721W, 6801W Comelit Art. 4577/4579 1 mm2 (Ø 1.2 mm AWG 17) UTP5 cat. 5 0.2 mm2 (Ø 0.5 mm AWG 24) 0.28 mm2 (Ø 0.6 mm AWG 23) 0.5 mm2 (Ø 0.8 mm AWG 20) 1 mm2 (Ø 1.
Distances valid for Art. 6601W Comelit Art. 4577/4579 1 mm2 (Ø 1.2 mm AWG 17) UTP5 cat. 5 0.2 mm2 (Ø 0.5 mm AWG 24) 0.28 mm2 (Ø 0.6 mm AWG 23) 0.5 mm2 (Ø 0.8 mm AWG 20) A MAX B MAX C MAX H MAX D MAX 160 m (525 feet) 70 m (230 feet) 90 m (295 feet) 30 m (98 feet) 100 m (328 feet) 80 m (263 feet) 40 m (130 feet) 40 m (130 feet) 30 m (98 feet) / 90 m (295 feet) 40 m (130 feet) 50 m (164 feet) 30 m (98 feet) 10 m (32.
Wiring diagrams Video entry phone system with 1 external unit Art. 4681: system commissioning/voltage test with system at rest.
Wiring diagram for system with external unit 4681 and supplementary power supply unit Art. 1595 (for maximum number of expansion modules). 110-240V L N L2 L2 L1 L1 1210 1595 - + 120-230 V SE SE - + C O M NC NO G N D 4681 D O R T E V V L + - L J1 J1 J1 J1 J1 J1 J1 J1 J2 J2 J2 J2 J2 J2 J2 J2 33433 33434 33436 33433 33434 33436 33433 33434 33436 33433 33434 33436 33433 33434 33436 33433 33434 33436 33433 33434 33436 N° 5 N° 6 N° 17 J9 J11 Local lock release button.
Wiring diagram for system with digital call module Art. 3360B 110-240V L N L2 L2 L1 L1 1210 SE SE - + C O M NC NO G N D D O R T E V V L + - J1 L P R G J2 G N D 4681/ 1621 485 485 D- D+ S 24 24 Vac Vac J1 J2 3360B Local lock release button. S2W/QNP Wiring diagram for system with external unit Art. 300(1-12)XVB 110-240V L N L2 L2 L1 L1 1210 SE SE - + C O M NC NO G N D D O R T E V V L + - L 300(1-12)XVB Local lock release button.
Wiring diagram for system with electronic digital key module Art. 3348B L 110-240V N L2 1210 L2 L1 L1 SE SE - + C O M NC NO G N D 4681 - 1621 D O R T E V V L + - L J1 J1 J2 J2 C NC NO C NC NO ~ 1 1 1 2 2 2 + 33433/33434/33436 (MAX 2 MODULES) ~ AL -+ R C D D K K + - 3348B Local lock release button.
Wiring diagram for system with electronic digital key module Art. 3348B and supplementary power supply unit Art. 1595 (for maximum number of expansion modules). L 110-240V N L2 1210 L2 L1 L1 1595 - + 120-230 V SE SE - + C O M NC NO G N D D O R T E V V L + - 4681 - 1621 L J1 J1 J1 J2 J2 J2 33433 33434 33436 33433 33434 33436 C NC NO C NC NO ~ 1 1 1 2 2 2 + 33433 33434 33436 ~ AL -+ R C D D K K + - 3348B J9 J11 Local lock release button.
Wiring diagram for system with single-plate entrance panel Art. 3063D 110-240V L N L2 L2 L1 L1 1210 SE SE - + C O M NC NO 4681 - 1621 G N D D O R T E V V L + - J1 L J2 J1 J1 J2 J2 V S + - C P 1 P 2 P 3 P 4 P 5 P 6 P 7 P 8 3063D 1172B N°1 N°1 3063D CV2 J1 1172B N°6 V S + - C P 1 P 2 (MAX 6) P 3 P 4 P 5 P 6 P 7 P 8 3063D (MAX 6 MODULES) N°6 Local lock release button. Use the cable included in Art. 1250IV, Art.
Wiring diagram for system with single-plate entrance panel Art. 3063D with supplementary power supply unit Art. 1595 (for maximum number of expansion modules). L 110-240V N L2 L2 L1 L1 1595 1210 - + 120-230 V SE SE - + C O M NC NO G N D D O R T E V V - + L J1 L J2 J1 J1 J2 J2 V S + - C P 1 P 2 P 3 P 4 P 5 4681 - 1621 P 6 P 7 P 8 3063D 1172B N°1 J9 J11 3063D CV2 J1 1172B V S + - C P 1 P 2 P 3 P 4 P 5 P 6 P 7 P 8 3063D N°30 Local lock release button.
Wiring diagram for system with Vandalcom entrance panel and conventional button modules Art. 3064S 110-240V L N L2 L2 L1 L1 1210 SE SE - + C O M NC NO G N D D O R T E V V L + - J1 L J1 J1 - J2 J2 1621+3262S 4681+3268S S V C + J1 J2 3064S N°1 S V C + 3064S N°2 J1 J2 S V C + 3064S N°3 - S V C + 3064S N°6 (MAX 6 MODULES) CV3 3064S N°6 1172B 1172B 1172B 1172B (MAX 6) Local lock release button. Use the cable supplied with Art. 3262S, Art.
Wiring diagram for systems with Vandalcom entrance panel and conventional button modules Art. 3064S and supplementary power supply unit Art. 1595 (for maximum number of expansion modules).
Wiring diagram for systems with digital call modules Art. 3070S and Art.3072S L 110-240V N L2 L2 L1 L1 1210 1595 - + 120-230 V SE SE - + C O M NC NO G N D D O 1621+3262S 4681+3268S J9 J11 R T E J1 V V L + - L J2 V V 12 12 S + -~~ - P R - "V -" BLUE "S" YELLOW "V+" BROWN D D + R T -- X X 3070S V V 12 12 S + -~~ - P R - D D + -- R T X X 3072S 2E7T000696 Local lock release button. Use the cable 2E7T000696 supplied with Art. 3070S and Art.
Wiring diagram for systems with Vandalcom electronic key module Art. 3188S 110-240V L N L2 L2 L1 L1 ~ ~ + - + C2 NC2 NO1 AL D- NC1 D+ - NO2 CK + OUT AC 1595 1210 120-230 V C1 PGM RK - 3188S SE SE - + C O M NC NO G N D D O R T E V - V + L - L 1621+3262S 4681+3268S S V C + 3064S J9 J11 J1 J1 J2 J2 CV3 Local lock release button. 3064S Use the cable supplied with Art. 3262S, Art.
Wiring diagram for systems with Art. SK9015 for connection of readers Art. SK9000I and Art.
Use of external unit relay on lock release or actuator command 1210 230 V SE SE - + C O M NC NO G N D R T E D O V V L + - L 4681/ 1621 12V/24V AC-DC 10A MAX “C.NC.NO relay activation on actuator command: 2 secs.” ff Set dip switches in permanent mode as shown in figure (Dip switch 8 ON, Dip switches 1,2,3,4,5,6,7 OFF) Local lock release button. S2W/RTNP Use of RC network for lock filter on relay contacts JP1 On C. NO contacts. On C. NC contacts.
Wiring diagrams for system with switching device Art. 1404 System with Art.
System with Art.
2 1216 L L + - L L L L C C F 1 F 2 P P S S IN IN + - 1 2 6801W/ 6801W/BM 1214/2C L L OUT OUT LM L L LM IN IN 2628/ 2638 L L C F P C F P P C S S 3 3 + - 1214/2C L L LM OUT OUT LM L L IN IN C F P C F P 6228B 6228W S S + - SW1 1214/2C L L OUT OUT S2 S1 LM L L LM IN IN 6721W 6721W/BM 6700W 6701W 6701B L L C C F 1 F 2 P P 1 2 3 4 5 6 1214/2C L L LM OUT OUT LM L L IN IN L L - + C C F 1 F 2 P P S S IN IN + - 1 2 6601W/ 6601W/BM 1214/2C L L OUT OUT LM L
System with Art.
6601W/ 6601W/BM L L - + C C F 1 F 2 P P 6601W/ 6601W/BM S S IN IN + - 1 2 L L - + C C F 1 F 2 P P S S IN IN + - 1 2 ON ON ON ON 12345678 S1 1234 5 67 8 S2 12345678 S1 1234 5 67 8 S2 MIN ON 12345678 S1 1404 MAX ON 12345678 S2 L L L L M M S S LP IN LP OUT A MIN JP1 B ON ON 12345678 S1 12345678 S2 1234 S3 L 110-240V L L L L M M S S LP IN LP OUT A JP1 B ON 1234 S3 L 110-240V N N L2 L2 L2 L2 L1 L1 L1 L1 1209 SE SE NC NO C - + 1404 MAX ON 1209 L L R
System with Art.
Wiring digram for systems with camera module Art. 1409 System Art. 1210: remote camera module Art.