CriticalPoint Public Safety BDA DIGITAL BAND SELECTIVE REPEATER USER MANUAL RXA3748/RXA3792 RXB3748/RXB3792 QE: 1-0-0 编 制: _ __ 审 核: __ 会 签: _ _ 标准化: _ 批 准: _ 京信通信系统(中国)有限公司
CriticalPoint PUBLIC SAFETY BIDIRECTIONAL AMPLIFIER USER MANUAL RXA3748/RXA3792 RXB3748/RXB3792 QE: 1-0-0 Comba Telecom Ltd.
INSTALLATION GUIDE FOR RX-7W22, II2 The information contained herein is the responsibility of and is approved by the following, to whom all enquiries should be directed: This is an unpublished work the copyright in which vests in Comba International ("Comba"). All rights reserved. The information contained herein is confidential and the property of Comba and is supplied without liability for errors or omissions.
INSTALLATION GUIDE FOR RX-7W22, II2 0.1 CONTENTS Section Page 1.1 1.2 1.3 1.4 1.5 CONTENTS ....................................................................................................................................... 4 INDEX TO FIGURES AND TABLES ............................................................................................. 6 HISTORY ...........................................................................................................................................
INSTALLATION GUIDE FOR RX-7W22, II2 7.4 7.5 7.6 APPENDIX D: TROUBLESHOOTING QUICK GUIDE ............................................................. 46 APPENDIX E: DEVICE REPORT EXAMPLE ............................................................................ 49 APPENDIX F: RMA (RETURN MATERIAL AUTHORIZATION) .............................................
INSTALLATION GUIDE FOR RX-7W22, II2 1.2 INDEX TO FIGURES AND TABLES Figure 1: Front, Side and Bottom Views of the PS BDA Enclosure .................................................................. 10 Figure 2: PS BDA Functional Block Diagram.................................................................................................... 14 Figure 3: Layout of the PS BDA ........................................................................................................................
INSTALLATION GUIDE FOR RX-7W22, II2 1.3 HISTORY Change No. ENU Details Of Change 1 1-0-0 This manual first created and issued in May. 2020.
INSTALLATION GUIDE FOR RX-7W22, II2 1.
INSTALLATION GUIDE FOR RX-7W22, II2 1.5 SAFETY NOTICES AND ADMONISHMENTS This document contains safety notices in accordance with appropriate standards. In the interests of conformity with the territory standards for the country concerned, the equivalent territorial admonishments are also shown. Any installation, adjustment, maintenance and repair of the equipment must only be carried out by trained, authorized personnel. At all times, personnel must comply with any safety notices and instructions.
INSTALLATION GUIDE FOR RX-7W22, II2 WARNING! Use only authorized and approved antennas, cables and/or coupling devices! The use of unapproved antennas, cables or coupling devices could cause damage and may be of violation of FCC regulations. The use of unapproved antennas, cables and/or coupling devices is illegal under FCC regulations and may subject the user to fine.
INSTALLATION GUIDE FOR RX-7W22, II2 1 GENERAL INFORMATION The RXA3748/RXA3792 (Class A), RXB3748/RXB3792 (Class B) is a new digital dual band public safety repeater (hereafter referred to as PS BDA) designed to protect the lives of first responders and building occupants. Through the use of digital filtering technology, the RX-7W22 helps eliminate adjacent channel interference to allow band selectivity and support 700MHz and 800MHz rebanding.
INSTALLATION GUIDE FOR RX-7W22, II2 Specifications-Class A (FCC ID:PX8RXA37) Electrical 700MHz 800MHz Frequency Range, Uplink MHz 799-805 806-817 Frequency Range, Downlink MHz 769-775 851-862 Channel Bandwidth KHz 12.5/25/100 12.
INSTALLATION GUIDE FOR RX-7W22, II2 Specifications-Class B (FCC ID: PX8RXB37) Electrical 700MHz 800MHz Frequency Range, Uplink MHz 788-798,799-805 806-816 Frequency Range, Downlink MHz 758-768,769-775 851-861 Operating Bandwidth MHz 0.2-10 0.
INSTALLATION GUIDE FOR RX-7W22, II2 The rated output power of this equipment is for single carrier operation. For situation when multiple carrier signals are present, the rating would have to be reduced by 3.5dB, especially where the output signal is reradiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device.
INSTALLATION GUIDE FOR RX-7W22, II2 2 EQUIPMENT DESCRIPTION 2.1 FUNCTIONAL BLOCK DIAGRAM Master Digital Boar d 30.72MHz 12.8MHz PLL1 RX_1 2 UL_PA AMP TX_2 ADC AMP FPGA AMP UL_LNA TX_1 RX_2 DAC ADC MCU AD9370_1 RTC AMP 32.768MHz 30.72MHz FB FS -30dB 12.8MHz PLL3 TX FB 12.8MHz 30.
INSTALLATION GUIDE FOR RX-7W22, II2 2.2 EQUIPMENT LAYOUT Shown below is the internal layout of the PS BDA.
INSTALLATION GUIDE FOR RX-7W22, II2 2.3 EQUIPMENT CONSTITUTION The typical PS BDA unit consists of the following components: Master Digital Board and Slave Digital Board: The MCU is used to monitor and control the operation of the repeater. It also provides the communication interface for remote control and status indication. LED indicators provide the operation status of the MCU.
INSTALLATION GUIDE FOR RX-7W22, II2 3 INSTALLATION 3.1 WARNINGS AND ALERTS Radio Frequency Energies There may be situations, particularly for workplace environments near high-powered RF sources, where recommended limits for safe exposure of human beings to RF energy could be exceeded. In such cases, restrictive measures or actions may be necessary to ensure the safe use of RF energy. High Voltage The equipment has been designed and constructed to prevent, as far as reasonably practicable danger.
INSTALLATION GUIDE FOR RX-7W22, II2 3.2 SITE PLANNING CONSIDERATIONS 3.2.1 SITE PLANNING Site Considerations Outdoor equipment is designed to be waterproof, rainproof, and with snow protection. Temporary protection should be taken when the equipment enclosure is opened for installation or maintenance in an outdoor environment. The equipment must not be opened for installation or maintenance in bad weather (e.g.
INSTALLATION GUIDE FOR RX-7W22, II2 3.2.2 INSTALLATION CHECKLIST Working space available for installation and maintenance for each mounting arrangement. Ensure unrestricted airflow. Ensure earth ground point is within reach of the ground wire. Ensure a power source is within reach of the power cord and the power source has sufficient capacity. Where appropriate, ensure unused RF connectors are terminated.
INSTALLATION GUIDE FOR RX-7W22, II2 3.3 INSTALLATION PROCEDURES 3.3.1 GOODS INWARDS INSPECTION Verify the number of packages received against the packing list. Check all packages for external damage; report any external damage to the shipping courier. If there is damage, a shipping agent should be present before unpacking and inspecting the contents because damage during transit is the responsibility of the agent. Open and check each package against the packing list.
INSTALLATION GUIDE FOR RX-7W22, II2 3.3.4 WALL MOUNTING Drill four holes on the wall using the position of four holes on the mounting rack as a guide. Fix the mounting rack to the wall using four masonry bolts (M10x110mm). Install the Mounting Rack to the wall. Hang the equipment and secure the enclosure to the mounting rack. Mounting Rack Masonry bolt 4-M10x110 6-M8x25, Hex socket with washer bolt RX-7W22 Figure 5: PS BDA Wall Mounting 3.3.
INSTALLATION GUIDE FOR RX-7W22, II2 3.4 EQUIPMENT CONNECTORS 3.4.1 PS BDA CONNECTORS The PS BDA is designed for all cable entries from the right or left of the enclosure, as shown in the following figure. Figure 6: Equipment Connectors Table 1: Equipment Connectors Identifier Descriptions Power (Knock Out) Power cable connector for a pre-installed power cord for connection to DC (e.g. DC -48V, Max.
INSTALLATION GUIDE FOR RX-7W22, II2 3.4.2 PS BDA LED INDICATORS The LED indicators help user to check the equipment status easily. Table 2: LED Indicators Identifier Colour Indication PWR Green Power indicator. ON = power on; OFF = power off. RUN Green Operation indicator, flashes every second to indicate normal operation. ALM Red Alarm indicator. ON = alarm; OFF = no alarm. 3.4.
INSTALLATION GUIDE FOR RX-7W22, II2 3.4.6 DRY CONTACT CABLE CONNECTION Below please find the pin definitions of dry contact cables. Table 3: Pin Definition of Dry Contact Cable Pin NO.
INSTALLATION GUIDE FOR RX-7W22, II2 4 COMMISSIONING 4.1 PRE-COMMISSIONING TASKS After equipment installation, perform the following steps before equipment powering and commissioning: Verify that the expected voltage, current and power levels do not violate any ratings. Visually inspect the power connection within the equipment. Ensure that the power cable is correctly and securely connected, including the grounding wire, RF cable and other cables.
INSTALLATION GUIDE FOR RX-7W22, II2 4.2 COMMISSIONING PROCEDURE Perform the following procedures for system commissioning.
INSTALLATION GUIDE FOR RX-7W22, II2 Table 4: Commissioning Task Explanation Commissioning Tasks 1. Isolation detection Observation Detect isolation of service antenna and donor antenna. Enter the center frequency of the main control channel, the commissioning guide will provide recommended DL/UL gain settings based on main control channel input power and the total channel numbers.
INSTALLATION GUIDE FOR RX-7W22, II2 5 WEB GUI The PS BDA can be monitored and controlled via the WEB GUI; use the following guide to finish system parameter setting and commissioning. 5.1 WEB GUI CONNECTION Step 1: Connect the OMT port to the PC RJ45 port with the supplied RJ45 cable to set up a physical connection. Step 2: Open a browser (browser IE7.0, IE8.0, Chrome or Firefox, suggested display resolution is 1024×768), input Web GUI IP address: 192.168.8.101, click [Enter].
INSTALLATION GUIDE FOR RX-7W22, II2 5.2 WEB GUI INTRODUCTION After log in, the Web GUI main screen will appear. Figure 11: Web GUI Main Screen On Comba Web GUI Home Screen, there are three Menu bars: [Home], [Commissioning], and [Management]. 5.2.1 [HOME] The [Home] Screen shows the equipment status, such as RF Switch status, PA status, alarm information, etc.
INSTALLATION GUIDE FOR RX-7W22, II2 ➢ Device Alarm This screen shows the alarm status. Figure 13: Device Alarm Screen ➢ 800MHz/700MHz This screen is available for PS BDA to adjust the center frequency and the bandwidth.
INSTALLATION GUIDE FOR RX-7W22, II2 5.2.2 [COMMISSIONING] A work flow of the commissioning process is shown on [Commissioning] Screen. Click the [Start] button, the software will guide you through the commissioning step by step. For details, please refer to chapter 5.3. Figure 15: Commissioning Screen 5.2.3 [MANAGEMENT] Other parameters can be configured on the [Management] Screen. It includes Device Info, Comm. Setting, Alarm Setting, Isolation, Reset, Firmware, Report, Log, License and Security.
INSTALLATION GUIDE FOR RX-7W22, II2 ➢ Device Info Figure 17: Management – Device Info ➢ Comm. Setting Figure 18: Management – Comm. Setting Note: There are 2 available communication types: SNMP and ETHERNET. You can choose a suitable type for remote monitoring.
INSTALLATION GUIDE FOR RX-7W22, II2 ➢ Alarm Setting Figure 19: Management-Alarm Setting Dry Contact Alarm and Ext Alarm can be set to show the target alarm accoridng to the Pre-set. The setting can be done by clicking “Modify”.
INSTALLATION GUIDE FOR RX-7W22, II2 ➢ Isolation There are two ways to detect the isolation, manually or Automatic by ICS function. Figure 21: Management – Isolation ➢ Reset Figure 22: Management – Reset Note: Click Restore, all the parameters and alarms will be reset to factory default value, or Click Reset to reset Device or PAs.
INSTALLATION GUIDE FOR RX-7W22, II2 ➢ Firmware There are two functions on the [Firmware] bar: [upgrade] and [swap]. [Upgrade] is used to upgrade software, and [Swap] is to replace the current firmware version with the previous one. Figure 23: Management – Report ➢ Report After commissioning, PS BDA can create the summary report about the setting of all the parameters.
INSTALLATION GUIDE FOR RX-7W22, II2 ➢ Log PS BDA can export the log file for troubleshooting. Figure 25: Management – Log ➢ License Figure 26: Management – License For the CriticalPoint BDA, users can switch the configuration anytime by changing the license in the WEBOMT. There are 4 difference licenses: 700MHz single band license, 800MHz single band license, Class A and Class B. Both 700MHz and 800MHz single band licenses are provided with a single band unit.
INSTALLATION GUIDE FOR RX-7W22, II2 If the equipment is in dual band originally, no license will be provided, because the equipment already comes with dual band activated. ➢ Security WEB GUI login password can be changed. Figure 27: Management – Security Note: After changing the password, please remember the new password for the next login.
INSTALLATION GUIDE FOR RX-7W22, II2 5.3 COMMISSIONING PROCEDURE To complete the installation and commissioning, users need to follow the steps below. Step 1: Click the Menu bar [Commissioning] on home screen, a work flow will be displayed. Figure 28: Commissioning Procedure – Start Step 2: Click to start the process. Figure 29: Commissioning Procedure – Site Info. Setting Step 3: Click ENU STATUS : 1-0-0 , to set the site information.
INSTALLATION GUIDE FOR RX-7W22, II2 It is mainly used to record device location and Date/Time provides a time reference. Clicking the Config Value of Date/Time will update the Date/Time automatically. NOTE: Make sure the device is connected with appropriate donor and service antennas before proceeding to step 4. Step 4: Click to enter to Isolation Detection Screen. Figure 30: Commissioning Procedure – Isolation Detection Select a frequency band (RFU) that needs to be commissioned.
INSTALLATION GUIDE FOR RX-7W22, II2 Step 5: After checking the isolation, Click device setting is shown. to finish the commissioning.
INSTALLATION GUIDE FOR RX-7W22, II2 6 MAINTENANCE The PS BDA is designed for trouble-free operation and generally does not need maintenance. Maintenance activities should only be carried out by trained personnel. Periodic inspection of the repeater equipment(s) is recommended, the recommended tasks includes: Verify the direction and position of antennas. Re-align if necessary. Make sure the cable connector and sealing on the RF cable connectors are not damaged.
INSTALLATION GUIDE FOR RX-7W22, II2 7 APPENDICES 7.1 APPENDIX A: Antenna installation: Installation of an antenna must comply with the FCC RF exposure requirements. The antenna used for this transmitter must be mounted on permanent structures. The FCC regulations mandate that the ERP of type B signal boosters should not exceed 5W, this is equivalent to 8.2W EIRP (39.1dBm).
INSTALLATION GUIDE FOR RX-7W22, II2 For example: Out of band noise RX-7W22 PS BDA connected to 10 service antennas with a 100m long ½ inch cable. Losses of such a cable with the connectors = 12dB Assuming 10 service antennas: antenna splitter losses = 10 dB Based on equation (2) Input antenna noise (to the antenna) = – 49.8 – 12 – 11= – 72.
INSTALLATION GUIDE FOR RX-7W22, II2 7.2 APPENDIX B: TOOLS The following are the recommended list of tools for new installation and routine maintenance. Slotted Screwdriver Philips Screwdriver Ring Spanner (Assorted size: 12~20mm) Electrically operated drill and masonry drill bits 12mm Anti-static Wrist Strap Side Cutter Frequency Counter (e.g. FLUKE PM6685R) RF Power Meter (e.g.
INSTALLATION GUIDE FOR RX-7W22, II2 7.3 APPENDIX CONTENT C: DECLARATION OF HARMFUL SUBSTANCES AND Product Name: Public Safety BDA Model: RX-7W22 Harmful substance and content of this product as below table shown: Part Name Harmful Substance Pb Hg Cd Cr (VI) PBB PBDE A × ○ ○ ○ ○ ○ B × ○ ○ ○ ○ ○ Note: Above table complies with SJ/T 11364.
INSTALLATION GUIDE FOR RX-7W22, II2 7.4 APPENDIX D: TROUBLESHOOTING QUICK GUIDE Alarm list: Signal Booster Failure Dry contact alarm Over Temperature alarm Low Input alarm PLL alarm VSWR alarm Antenna Malfunction Dry contact alarm LNA alarm DL PA alarm Shutdown alarm High input alarm Figure 33: Alarm list Troubleshooting: Alarms Causes and actions Low input (for DT port) DT composite input power lower than -80dBm will trigger the alarm 1. Donor antenna/passive system failure 2.
INSTALLATION GUIDE FOR RX-7W22, II2 Reset PA: The Downlink PA will try to automatically reboot during the first 2 hours after alarms occur and then may shutdown permanently if alarms still exist. Users need to manually reset the PA in WEBOMT after fixing the alarm.
INSTALLATION GUIDE FOR RX-7W22, II2 2. Any changes or handling of the RF connection requires user to switch off RF power (RF switch off in WEBOMT) or power off the unit first.
INSTALLATION GUIDE FOR RX-7W22, II2 7.
INSTALLATION GUIDE FOR RX-7W22, II2 7.
INSTALLATION GUIDE FOR RX-7W22, II2 ENU STATUS : 1-0-0 Copyright - refer to title page Page 51