USER MANUAL FOR RD-8132 RD-8132 CDMA REPEATER USER MANUAL The information contained herein is the responsibility of and is approved by the following, to whom all enquiries should be directed in the first instance: Comba Telecom Ltd This is an unpublished work the copyright in which vests in Comba International ("Comba"). All rights reserved. The information contained herein is confidential and the property of Comba and is supplied without liability for errors or omissions.
USER MANUAL FOR RD-8132 0.2 CONTENTS Section Page 0.2 0.3 0.4 0.5 CONTENTS ...........................................................................................................................2 INDEX TO FIGURES .............................................................................................................3 ISSUE CONTROL..................................................................................................................3 SAFETY NOTICES AND ADMONISHMENTS ..................
USER MANUAL FOR RD-8132 0.3 INDEX TO FIGURES Figure 1: Block Diagram................................................................................................................................. 6 Figure 2: Equipment Enclosure Layout .......................................................................................................... 7 Figure 3: Equipment Internal Layout ..............................................................................................................
USER MANUAL FOR RD-8132 0.4 ISSUE CONTROL Change No. ENU Details Of Change 1 1-0-0 First created and issued on 2008-09-24.
USER MANUAL FOR RD-8132 0.5 SAFETY NOTICES AND ADMONISHMENTS This document contains safety notices in accordance with appropriate standards. In the interests of conformity with the territory standards for the country concerned, the equivalent territorial admonishments are also shown. Any installation, adjustment, maintenance and repair of the equipment must only be carried out by trained, authorised personnel. At all times, personnel must comply with any safety notices and instructions.
USER MANUAL FOR RD-8132 1 EQUIPMENT DESCRIPTION The RD-8132 CDMA repeater is designed for CDMA850 networks. Band-specific linear MCPA and filtering effectively amplifies the desired BTS carriers and provides superior out-of-band rejection. The unit can incorporate two adjustable bandwidth segments. Remote configuration and surveillance is possible through Comba’s remote control and monitoring system via PC or wireless modem to the OMT/OMC.
USER MANUAL FOR RD-8132 1.2 EQUIPMENT CONSTITUTION 1.2.1 EQUIPMENT ENCLOSURE LAYOUT 600 Below is the enclosure layout: 295 450 Figure 2: Equipment Enclosure Layout 1.2.2 EQUIPMENT INTERNAL LAYOUT This system typically consists of the following sub modules.
USER MANUAL FOR RD-8132 No 3 4 Identifier UL Frequency Selective Module DL Frequency Selective Module UL Power Amplifier (PA) DL Power Amplifier (PA) 5 Integrated DPX (DT) 6 Integrated DPX (MT) 7 Main Control Unit(MCU) 8 Power Supply Unt (PSU) 9 Li-ion Battery 10 Distribution Board 11 Surge Protector 12 Wirelss Modem 1 2 Functional Description The frequency selective module is used to select desired signals and filter unwanted signals effectively.
USER MANUAL FOR RD-8132 2 INSTALLATION 2.1 INSTALLLATION CHECKLIST AND PREPARATION 2.1.1 REPEATER INSTALLATION CHECKLIST Installation Location Requirement Considerations Provided power cord length is about 4m. Use a dedicated AC breaker or fuse circuit with good access to an earthing point. Here are the power supply options for this repeater: AC100~240V: 100V~240V/47Hz~63Hz Power Supply Do not locate near large transformers or motors that may cause electromagnetic interference.
USER MANUAL FOR RD-8132 Knife for tape or cable stripping Multi Meter to check cables, voltages alarms PC with supplied OMT or OMC software SIM cards both for repeater and modem with SMS (Short Message Service) and CSD (Circuit Switch Data) enabled External alarm cable for connction to external alarm terminals Fused Power Outlet for repeater 2.2 ELECTRICAL INSTALLATION The equipment has been designed for all cables entry from the bottom of the enclosure.
USER MANUAL FOR RD-8132 Here blow is the electrical installation application. Figure 5: Equipment Connections 2.2.1 GROUNDING CONNECTION The enclosure must be grounded securely by connecting a copper wire (CSA 16mm2) to the grounding point on the mounting rack, and the other end to a protective ground (i.e. building earth point). 2.2.2 POWER CONNECTION The system provides power supply options of AC220V/50Hz, AC110V/50Hz. The recommended AC connection has three connections to include earth. 2.2.
USER MANUAL FOR RD-8132 2.2.5 OMT CONNECTION With the chassis open, only use the local commissioning cable (R-9122C/R-9122AC) directly connects the serial port of PC to the RS-232 port on the distribution board within the equipment. Distribution Board RS-232 Figure 6: OMT Connection with Chassis Open 2.2.6 EXTERNAL ALARM CONNECTION Four external alarms INPUT are realized on the EXT_ALM port, this is a 7-pin CPC connector. Pin numberings are shown looking-into the connector on the enclosure.
USER MANUAL FOR RD-8132 Note: When CDMA modem is used, only SMS function is supported to retrieve alarm information and to provide remote control. The power and data cables have been factory-connected to the wireless modem. User needs to insert the SIM / UIM card into the wireless modem. To insert or replace the SIM / UIM card, locate and press down the recessed button (yellow) to eject the SIM / UIM card carrier. Insert the SIM / UIM card and push back the carrier until it is latched in place.
USER MANUAL FOR RD-8132 3 OMT The equipment can be monitored and controlled by OMT software running on a local PC with local commissioning cable, remote connection to the equipment via wireless GSM / CDMA network. z z OMT software running on a local PC with serial connection to the equipment. OMC (optional) software with remote connection to the equipment over wireless GSM / CDMA network.
USER MANUAL FOR RD-8132 3.1.2 REMOTE CONNECTION TO OMT If remote connection is needed, users can select [Remote connection via modem] in connection type window. Select desired serial port and click “OK” in [Serial Port Configuration] window to go to OMT main window and start modem initialization. Click “connect” and the [Remote Connection] window will show up.
USER MANUAL FOR RD-8132 3.3 RF PARAMETER It is recommended to configure the following RF parameters for the first installation. 3.3.1 SWITCH Switch is to enable/disable power for carrier1,carrier2, RF and self-oscillation. When user checks and sets non-RF parameters, such as checking physical antenna connection, switching off will disable equipment power temporarily to protect PA in operation.
USER MANUAL FOR RD-8132 Config: Enter the required value in setting columns and click [Config] button to finish the configuration operation. There are two methods to insert the channel number: z Insert the desired channel number (within the setting range) into the [Setting] column directly z Right click the [Setting] column, the [Frequency Calculator] dialogue window seen as below will popup, insert the desired channel number. Then the corresponding frequency will turn up automatically.
USER MANUAL FOR RD-8132 Figure 17: Alarm Threshold Config: Enter the required value in setting columns of RF information window for Alarm threshold, and press [Enter] or [Config] button to finish the configuration operation. Alarm Threshold DL Output Power Low Threshold DL Input Power Overload Threshold DL Input Power Low Threshold PA Over-Temperature Threshold DL VSWR Threshold Setting Range 14~45dBm -70~-49dBm -70~-49dBm -40~125 oC 1.5, 2.0, 2.5 Initial Setting 14dBm -49dBm -49dBm 80 oC 2.
USER MANUAL FOR RD-8132 Figure 18: Master Alarm Figure 19: Channel Alarm RD-8132 QI ENU Status : 1-0-0 Copyright - refer to title page Page 19
USER MANUAL FOR RD-8132 Figure 20: External Alarm Config: Tick the check box of [Item select] and [Enable] of the desired parameters and click [config] button to finish configuration operation. Notice: [Enable] box is to enable the alarm monitoring for system. Only if users enable the alarm by ticking the [Enable] box, the alarms can be monitored by the OMT/OMC. On the MCU, if any alarm is generated and this alarm is also enabled in [Enable] box, LED H2 turns RED; while it is OFF when normal working.
USER MANUAL FOR RD-8132 [00~FF]. For the system located with single equipment, the Site Sub ID should be FF. For Master-Slave system, the Site Sub ID for Master Unit is 00, and the Site Sub ID for each Slave Unit is represented in the range of [01~FE] in ascending order. e.g. Master Site ID: 00, Slave Site ID: 01 3.4.2 COMM. CONFIG If the equipment is to be monitored by OMC software over wireless GSM / CDMA network, users must finish the [Comm. Config.] in the next step. The Comm.
USER MANUAL FOR RD-8132 4 COMMISSIONING 4.1 PRE-COMMISSIONING TASKS After equipment installation, perform the following steps before equipment powering and commissioning: Check the expected voltage, current and power levels do not violate any ratings. Visually inspect the power connection within the equipment. Ensure that the power cable is correctly and securely connected, including grounding wire, RF cable and other cables. Check grounding connection and verify that the ground resistance is less than 5Ω.
USER MANUAL FOR RD-8132 4.3 COMMISSIONING PROCEDURE System commissioning can commence after the monitoring system has completed self initialization. The commissioning procedure is as follows: On- line & Inquiry Status Set Channel NO . Signal Input Adjust Downlink ATT and Measure Downlink Output Power Remote Connection to OMC No Yes Configure [Equipment ID] Comm.
USER MANUAL FOR RD-8132 Commissioning Tasks 1. On-line and Inquiry status 2. Set Channel No. 3. Adjust Downlink Output Power and align donor antenna 4. Configure [Equipment ID] 5. Comm. Config 6. Select Parameters Monitoring 7. Test coverage area field intensity and adjust service antenna. 8. Verify UL gain and ensure test call produces good voice quality and there is no interfering BTS Observation z Activate the OMT Main window. The system Initialization will completed in about 2 minutes.
USER MANUAL FOR RD-8132 5 TROUBLESHOOTING Following installation and commissioning, troubleshooting tasks to handle alarms may be required. Here below is the alarm list of the equipment and diagnosis. Alarm Diagnosis AC Power Failure Alarm DC Power Fault Alarm z Check AC power cable and verify AC mains supply is normal. During power failed alarm, DC power supply has no output. z Check if DC output power is overload or short-circuited, if not, it would be the fault of PSU.
USER MANUAL FOR RD-8132 6 APPENDICES 6.1 APPENDIX A: SERVICE POLICY AND RETURN OF EQUIPMENT The repair of individual units and modules of this equipment is not considered practicable without factory facilities. It is, therefore, the policy of Comba whereby faulty units or modules are returned to the local agent for repair. To enable an efficient, prompt after sales service to be provided for the diagnosis, repair and return of any faulty equipment, please comply with the following requirements.
USER MANUAL FOR RD-8132 6.