Comark Survey Kit Hardware Manual Registered Office: Bury Mead Road Hitchin Hertfordshire SG5 1RT United Kingdom Registration No. 2929930 Telephone: 0844 (+44 844) 815 6599 Facsimile: 0844 (+44 844) 815 6598 Email: salesuk@comarkltd.com – UK & Ireland salesint@comarkltd.com – International Internet: www.comarkltd.
Comark Survey Kit Hardware Manual Contents Table of Contents Survey Kit System Components.................................................................................................3 Contents:.................................................................................................................................3 Know Your Survey Kit..........................................................................................................3 RF505..................................................
Survey Kit System Components Contents: 1x RF505 Survey Gateway 1x USB Type A to B lead 1x USB Driver CD 1x Survey Forms CD 1x Surveying Guide 6x RF512 Survey Transmitters 6x Hi Gain Antenna's 7x Standard Antenna's 3x Spare C Size Lithium Batteries Know Your Survey Kit RF505 Figure 1 – Front view of RF505 Survey Gateway A. Activity LED B. Antenna. (Do not remove whilst in operation) Figure 2 – Connector view of RF505 Survey Gateway A.
RF512 Survey Transmitter Figure 3 – Front view of RF512 Survey Transmitter A. B. C. D. E. Activity LED Activity LED Infra-Red interface. For Comark use only Antenna. (Do not remove whilst in operation) Survey Transmitter activation key Figure 4 – Front view of RF512 Survey Transmitter A. Activation key receptacle B. Lumberg socket, NOT USED C.
Safety Information Under no circumstances may a user make any changes to the RF505 or RF512 survey transmitters in such a way that would alter their performance. Any modification would void the CE compliance and may invalidate any warranty. If the equipment is used in a manner not specified by Comark, then the protection provided by the equipment may be impaired. No user serviceable parts are provided in Comark Wireless Survey (RF505 & RF512 survey transmitters) Equipment.
Survey Kit Overview The Survey Kit is designed to enable evaluation of a potential RF500 customer premises. The Kit enables the user to identify critical RF “choke points” and strategic locations for “meshing” units making the actual RF500 install a smooth and trouble free process. Equipment Use Powering On and Off PLEASE ENSURE THE ANTENNAS HAVE BEEN FITTED. IT IS ESSENTIAL TO AVOID DAMAGE. RF505 The RF505 does not have an on/off button, simply plug it into a free USB port on your computer (Fig.
Changing Batteries on Survey Transmitters Battery Reordering RF512 survey transmitters are fitted as standard with a high power 3.6V Primary lithium-thionyl chloride C-size cell. Manufacturers part number Saft LSH14 LIGHT. Only replace with the same or equivalent type recommended by the manufacturer. Re-Order number from Comark ‘RFBATT’. Battery Change Procedure (Survey Transmitters Only) • Using a suitable screwdriver undo the two battery cover retaining screws and remove the battery cover.
Equipment Ratings Environmental Conditions The Comark Wireless Survey equipment is designed for indoor use only. RF505 Storage/Operating Conditions Temperature –30 to +70°C Humidity 10-90% RH (Non-condensing) RF512 Survey Transmitter Operating Conditions Temperature –30 to +70°C Humidity 10-90% (Non-condensing) RF512 Survey Transmitter Storage Conditions Temperature –40 to +85°C Humidity 10 to 90% RH (Non-condensing) Maintenance and Cleaning No specific maintenance is required for the Survey equipment.
Declaration of Conformity DofC Survey Kit Comark Limited Bury Mead Road Hitchin Herts. SG5 1RT Comark Wireless Survey Equipment Comprising Part Numbers: RF505 & RF512 Is in conformity with the requirements of the following documents (Directives): EMC Directive 89/336/EEC. The Low Voltage Directive (73/23/EEC) as amended 93/68/EEC Radio & Telecommunications Terminal Equipment Directive (R&TTE) 1999/5/EC Standards: EN 61010-1:2001 ETSI EN 301 489-17 V1.2.
RF505 & Survey Transmitter Specification RF Frequency 2.4GHz using IEEE 802.15.4 Operating Range: RF505 RF512 Survey Transmitter –30 to +70°C –30 to +70°C Power Sources: RF505 RF512 Survey Transmitter Supplied By USB Port Saft LSH14 Light Standard Antenna High-Gain Antenna (optional) External, removable, Omni directional with pivot.
Glossary Antenna – The Gateway and associated transmitters are provided with an antenna. The antenna is designed for both transmit and receive and is configurable for either horizontal or vertical mounting. FCC – Federal Communications Commission. Firmware – The micro-processor program that runs in each transmitter. Frequency – Number of cycles-per-second of the radio signal. License free – Term used to describe a radio frequency band in terms of license to broadcast. RF500 uses the license free band of 2.
Document Revision History Release-1 2008xxxx Original Release.