EF-45N™ Next Generation Iris Recognition System (Derivative Model : EF-45, UMX-10, UMX-20, UMX-G) User Manual (v0.1.1, July 1, 2016) Intuitive face display positioning Internal automatic motorized tilt cameras LAN / RS485 Optional face image capture and face recognition User graphics and screen shots in this guide may vary from actual Some of the contents in this manual may differ from current operating library release www.cmi-tech.com Copyright 2016, all rights reserved v0.1.
Introduction to the EF-45N™ Iris Recognition System This new iris recognition system offers highly intuitive, hands-free iris biometrics imaging in a compact and elegantly designed identification and authentication terminal for use in a wide range of identity management applications. The front facing nominal 5.0 inch LCD serves to display the user’s face image for fast, easy and highly natural positioning for proper iris image capture.
Key Features · Iris user interface with intuitive LCD display face positioning, like smart phone “selfie” · Contactless iris imaging at range of 35 to 45 cm stand-off · Internal, automatic face and iris camera tilt mechanism with nominal height range of 50 cm · Positioning guidance vocalizations selectable on / off and delay time. English standard, all other languages available with .
Cautions FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Accessories Kit ID Management Version Access Control and Time & Attendance Versions Power supply (IEC C13 female) Yes Yes Power cord (IEC C14 male), power side connector type by country Yes Yes Basic MiFare / DesFire card reader (internal) No Yes Standard back cover Yes No Wall mount bracket No Yes ID I/O cables with push in connectors for device, and pig tails for external connections Yes No No Yes Yes Yes Includes: Includes cables for RS 485, RS 232, TTL (2), dry contact relay AC
Mounting Instructions 50 cm 144 cm Recommended mounting height and UI (left), Capture Volume of EF-45N (right) The recommended mounting height for the EF-45N is 144cm (57 inches) from floor to the bottom of EF-45N. The mounting height can be adjusted to accommodate the height of the average user. High ambient light and / or direct light into the EF-45N should be avoided.
System, Front System, Bottom www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
System, Rear System Rear Connections Block www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
User Interface for Iris Image Capture l Position yourself facing straight at the LCD display. When the device detects your movement within 1.0 meter parameter, it initiates the image capture sequence. A rectangular-shaped user guide box will appear on the screen. If it is BLUE, it means you are too far from the device. Move forward. l Move towards the system to size your face to the LCD display. If the user guide box flashes GREEN, it means you are at an appropriate position.
On-board Demonstration Application The on-board demonstration application shows the full capabilities of the EF-45N for image capture including subject positioning with the face display user interface, enrollment, and on-board matching (authentication). The system boots up in this demo application.
The following main User screen appears: This user screen also allows simple database management. By tapping the Delete icon in the bottom right, one can easily delete information of enrolled users. To enroll a new user, press the Enroll icon to bring up Enroll User screen. Press the plus(+) button in the bottom left to capture image of the new user. www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
An instruction screen will appear for 3 to 5 seconds, and then switch to the user interface. After successfully capturing iris images, click on √OK to accept images. The system then returns to Enroll User screen. Click on Name field to enter name of subject, then click on √OK complete enrollment. Name field Press the Home icon ( ) to return to the Launcher page to re-start Recognition and Authentication mode. www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
Summary of Specifications Software and Platform Technical Specifications (Tentative) Embedded CPU and OS Freescale iMX6 Cortex A9 Quad Core ARM with Linux Yocto v1.
Other Technical Specifications (Tentative) (continued) Auto tilt Yes, internal: +25 deg to -20 deg tilt Iris inter-pupillary distance covered 45 to 85 mm Iris time of capture Typically about 0.5 second from time subject’s eyes are placed within proper capture volume IR illumination for iris imaging Dual LED: wavelengths of 850 nm nominal (about 50%); and 750 nm nominal (about 50%) Iris maximum user positioning speed 125 mm per second (4.9 inches per sec.
Contact Information CMITech Company, Ltd. 5th Floor, 38, Burim-ro, 170beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do,14055, Republic of Korea Tel : +82.70.8633.8278 Fax: +82.31.624.4490 Contact: sales@cmi-tech.com www.cmi-tech.com Copyright 2016, all rights reserved CMITech America, Inc. 2033 Gateway Place, Suite 500 San Jose, CA 95110 USA Tel: (1) 408 573-6930 EF-45N User Manual, v0.1.
Appendix 1 EF-45N LCD Control Screens and On-Board Demo Application Main Launcher Page ① Check Attendance (F1 Key) ⑧Notice Icon of Face mode is operating ② Leave Work (F2 Key) ⑨Notice Icon of CMID manager is connected ③ Supplement T&A (F3 Key) ⑩Notice Icon of IP network is connected ④ Go Out (F4 Key) ⑤ Return Button (same as F5 Key) ⑪Notice Icon of Serial Communication is connected ⑥ Interphone Call Button (same as F6 Key) ⑫Clock display ⑦ Notice Icon of Iris mode is operating ⑬User Button for
Table of Contents Settings 1 Device Configuration 1.1.1 User Positioning Interface 1.1.2 Motion Wait Time 1.2 Bio 1.2.1 Security Level 1.2.2 Iris 1.2.2.1 Max Distance 1.3 Sound 1.3.1 Speaker Volume 1.3.2 MIC Volume 1.4 Date & Time 1.4.1 Manual Setup 1.5 Door 1.5.1 Relay 1.5.2 Driven By 1.5.3 Duration 1.5.4 Door Sensor 1.5.5 Door Sensor Type 1.5.6 Held Open Period(sec) 1.5.7 Lock Time 1.5.8 Unlock Time 1.6 Device Info 1.7 Interphone 1.7.1 IP Address 1.8 Memory Info 1.9 Camera 1.9.1 Power Line Frequency 1.
Settings Tap the Settings icon in the home screen. Device Configuration for device operating Network Configuration for IP & serial communication Display Configuration for screen display Authentication Configuration for authentication method and T&A Mode Configuration for recognition operation Log Information of saved log and log search viewer (Note: In construction) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1 Device Configure settings for device operation. 1.1 Configuration User Positioning Interface Select a guide display UI when enrollment and recognition Motion wait time Set motion detection delay time from last recognition operating Motion detect Select motion detection enable/disable for starting recognition Debug Select Debug mode enable/disable (captures image stream for offline analysis) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.1.1 Configuration à User Positioning Interface ColorLR-Ov Select Color overlay type guide UI display Box Select tracking box type guide UI display 1.1.2 Configuration à Motion Wait Time www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.2 Bio Security Level Select a combination mode of Face and Iris Iris Additional configuration for Iris enrollment and recognition Face Additional configuration for Face enrollment and recognition (note: in construction) 1.2.1 Bio à Security Level (Must have face recognition option) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
Face or Iris Select 2 stage Face or Iris recognition mode (Face recognition first, and then automatic switch-over to Iris upon Face recognition nonmatch) Face only Select Face only recognition mode Iris only Select Iris only recognition mode Face and Iris Select 2 stage Face and Iris recognition mode (Face recognition first, and then automatic switch-over to Iris upon multiple matches) (note: in construction) 1.2.
1.2.2.1 Bio à Iris à Max Distance www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.3 Sound Speaker volume Set speaker volume for instruction sound and interphone voice MIC volume Set microphone volume for interphone voice (note: in construction) 1.3.1 Sound à Speaker Volume 1.3.2 Sound à MIC Volume Identical to settings for speaker volume www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.4 Date & Time Time sync Select enable/disable for time sync with CMID manager Manual setup Set date and time manually 1.4.1 Date & Time à Manual Setup www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.5 Door Relay Select a door open relay Driven by Select an event mode for door open relay Duration (sec) Set time duration for door open relay operation RTE (Request to Exit) Select a door exit button (Note: in construction) RTE Type Select a door exit button operating type (Note: in construction) Door sensor Select a door sensor (Note: in construction) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
Door sensor type Select door sensor operating type (note: in construction) Held open period (sec) Set time duration for door open operation (note: in construction) Lock time Set door lock time (note: in construction) Unlock time Set door unlock time (note: in construction) Tamper Select enable/disable for tamper (off the wall detection) operation 1.5.1 Door à Relay Not use Select not use Internal Relay Select internal relay www.cmi-tech.
1.5.2 Door à Driven by All Events Select door open for all events Authentication Select door open for authentication event T&A Event Select door open for T&A event Authentication + T&A Event Select door open for authentication plus T&A event Disabled Select door open disable 1.5.3 Door à Duration (sec) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.5.4 Door à Door Sensor 1.5.5 Door à Door Sensor Type N/O Select door exit button sensor as Normal Open type N/C Select door exit button sensor as Normal Close type www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.5.6 Door à Held Open Period (sec) 1.5.7 Door à Lock Time Never Select door lock time -- never Always Select door lock time -- always www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.5.8 Door à Unlock Time Never Select door unlock time -- never Always Select door unlock time -- always www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.6 Device Info Model Model name of this device FW Version Version name of released firmware (F/W) file Device ID Identification number of this device Kernel version Revision number of kernel HW version Revision number of hardware board MAC MAC address of this device www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
Boot version Revision number of boot loader Root version Revision number of root file system Recovery version Revision number of recovery firmware Application version Revision number of Launcher application FPGA version Revision number of Camera FPGA firmware www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.7 Interphone Interphone Select enable/disable for interphone use (note: in construction) IP Address IP address of PC which interphone program is installed (note: in construction) 1.7.1 Interphone à IP Address www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.8 Memory Info System Memory capacity of system area (note: in construction) User data Memory capacity of user area (note: in construction) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.9 Camera Power line frequency Select power line frequency that supplying to device 1.9.1 Camera à Power Line Frequency 50Hz Select power line frequency to 50Hz 60Hz Select power line frequency to 60Hz www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.10 Reset Reboot Reboot device Factory Default Reset all configuration settings and/or delete all user data 1.10.1 Reset à Reboot www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.10.2 Reset à Factory Default Reset all settings Reset all configuration settings Delete all data Delete all user data Delete all data and reset all configuration settings Reset all configuration settings and delete all user data 1.10.2.1 Reset à Factory Default à Reset All Settings www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.10.2.2 Reset à Factory Default à Delete All Data 1.10.2.3 Reset à Factory Default à Delete All Data and Reset All Settings www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
2 Network Configure settings for IP and serial communication. 2.1 TCP/IP LAN type Select a type of LAN DHCP Select enable/disable DHCP mode IP Address Set static IP address Gateway Set static gateway IP address Subnet Set static subnet mask www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
2.1.1 TCP/IP à LAN Type Disable Disable LAN use Ethernet Select Ethernet for LAN use 2.1.2 TCP/IP à IP Address www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
2.1.3 TCP/IP à Gateway 2.1.4 TCP/IP à Subnet www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
2.2 Server (Currently settled server is CMID PC for time sync) Use Server Select enable/disable for server use (Note: In construction) Server IP Set IP address of server (Note: In construction) Port (Note: To be eliminated) 2.2.1 Server à Server IP www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
2.3 Serial RS485-PC Select a baud rate for RS485 (note: in construction) RS485-NET Select an operating mode for RS485 (note: in construction) RS232 Select a baud rate for RS232 (note: in construction) 2.3.1 Serial à RS485-PC www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
2.3.2 Serial à RS485-NET Not use Disable RS485 NET-HOST Set RS485 operating mode as host NET-SLAVE Set RS485 operating mode as slave 2.3.3 Serial à RS232 www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
2.4 USB Memory USB enable Select enable/disable for USB memory use FW Upgrade Go into firmware (F/W) upgrade from USB memory Import Go into backup data (user & log data) restore from USB memory Export Go into backup data (user & log data) save to USB memory 2.4.1 USB Memory à FW Upgrade www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
Upgrade F/W by tapping on √ OK button on the bottom right. If the FW file (new firmware and operating library) does not exist in USB, message appears as shown above. 2.4.2 USB Memory à Import User data Restore user enroll data from USB memory Log data Restore log data from USB memory www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
2.4.3 USB Memory à Export User data Backup user enroll data to USB memory Log data Backup log data to USB memory www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
3 Display Configure settings for screen display. 3.1 Voice Instructions Voice Instruction Select enable/disable for voice guide positioning / instructions www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
3.2 Central Timer Central Timer Select enable/disable for clock display on the center of Launcher application 3.3 Menu Timeout Menu Timeout Set timeout for auto exit from menu display after leaving untouched www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
3.4 Screensaver Logo Select logo display as screensaver Time Select clock display as screensaver 3.5 Pop-Up Timeout Pop-Up Timeout Set pop-up message window (recognition complete etc.) display duration www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
3.6 Backlight Timeout Pop-Up Timeout Set timeout for auto off of LCD backlight after leaving unused 3.7 Date Display YYYY/MM/DD Select year/month/day display mode DD/MM/YYYY Select day/month/year display mode www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
3.8 Language Language Select a language to use (Note: In construction) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
4 Authentication Configure settings for authentication method and T&A. 4.1 Auth. Start mode Select a basic (first) recognition method Combination mode Select a combination (additional) recognition method if necessary www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
4.1.1 Auth. à Combination Mode (Step 1) Select a combination (additional) recognition method. 4.2 T&A Use T&A Select enable/disable for T&A usage mode (note: in construction) T&A >Recognition Select T&A mode (Attendance etc.) first, then recognition Recognition > T&A After recognition, then input T&A mode (Attendance etc.) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
4.3 T&A Mode (Note: In construction) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
5 Mode Configure settings for recognition operation. 5.1 Operation Face detection Select enable/disable for face image saving at recognition (note: to be eliminated) Individual auth. Select enable/disable for permission of individual authentication Dual authentication Select a dual authentication (simultaneous 2 persons) method (note: in construction) Match timeout Set a recognition trying timeout Card mode Select use or not for CSN in RFID card (note: in construction) www.cmi-tech.
5.1.1 Operation à Dual Authentication 5.1.2 Operation à Match Timeout www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
5.1.3 Operation à Card Mode www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
6 Log View information of saved log and log search viewer. 6.1 Log Info (Note: In construction) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
User Tap the User icon in Home screen. Displays the registered user lists in All and Group 1, 2, 3, 4 Enroll button Switch to enroll process Search button Switch to search process Capacity Info button Show the used memory percentage Delete button Switch to delete process www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1 Enroll User Tap the Enroll button to enroll a new user. Enroll User Page ① ID: Created a user ID number automatically or input manually ② Name: Input user name manually ③ Individual: Set user individual authentication mode if necessary ④ Admin: Can make a user administrator or not ⑤ Group: Can make a user belong to a group ⑥ Bypass Card: Can register a user who holding bypass card (highest priority card) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.1 Name 1.2 Individual Select an individual authentication mode. www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.3 Group 1.4 Iris & Face Process Iris & Face tab Selection changes tab to blue color Bio select check boxes are shown Face Select box for face image capture Glasses wearer Select box for face taking off glasses additionally if necessary www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
Both eye Select box for “both eye” Iris mode Either eye Select box for “either eye” Iris mode Start(+) button Switch to enroll process 1.4.1 Iris & Face Process à Face Capture ※ Note: Only operational if “Combined Face and Iris” mode is active Color Overlay BLUE means too far GREEN means OK RED means too close. Up/Down Arrow Can tilt camera manually if necessary (note: to be eliminated) Switch to Iris Capture stage after good face image acquisition www.cmi-tech.
1.4.1.1 Iris & Face Process à Face Capture à Tracking Guide Box UI Positioning box appears in order to guide subject. Capture normal face images. www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
In case of selection of Glasses wearer check box, will be active for about 3 to 5 seconds. Capture additional face images taken off glasses. www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.4.2 Iris & Face Process à Iris Capture In case of Tracking Guide Box UI mode, display will be active for about 3 to 5 seconds. 1.4.2.1 Iris & Face Process à Iris Capture à Tracking Guide Box UI Capture iris images. www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.4.3 Iris & Face Process à Save Data / Complete Enrollment Reset Return to face capture stage Cancel Return to Enroll User screen OK Move to next screen to complete enrollment 1.4.4 Iris & Face Process à Complete Enrollment Cancel www.cmi-tech.com Copyright 2016, all rights reserved Return to User Main screen EF-45N User Manual, v0.1.
OK Save user data to complete biometrics Enrollment, then return to User Main screen 1.5 Card Card tab Selection changes tab to blue color If "Please tag your card" message appears, touch front-bottom part of device with user card. 1.5.1 Card à Save Data www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
Card number is shown on tagging a card Reset Clear card number and "Please tag your card" message is shown Cancel Return to User Main screen OK Save user data and return to User Main screen 1.6 Pin PIN tab Selection changes tab to blue color Start (+) button Switch to input screen www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
1.6.1 Pin à Input 1.6.2 Pin à Save Data Pin number is shown as "*" character. Reset Clear pin number and (+) button is shown Cancel Return to User Main screen OK Save user data to complete PIN enrollment / return to User Main screen www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
2 Search Tap the Search icon to browse list of enrolled users. (Note: In construction) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
3 Capacity Info Tap the Capacity Info icon to check storage space. (Note: In construction) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
4 Delete Delete information of enrolled user. Select All Select all users Deselect All Deselect all users Cancel Return to User Main screen Delete Delete selected user(s) www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
Recognition Process 1.1 Recognition Process Recognition process is identical to the enrollment process. 1.2 Recognition / Authentication Success 1.3 Recognition / Authentication Failure www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.
When access is denied, warning icons can appear on the screen. . Glasses: Device detects occlusion by glasses. . Color Lens: Device detects colored lenses. . Small Eye: Device cannot fully detect iris due to eyelid. www.cmi-tech.com Copyright 2016, all rights reserved EF-45N User Manual, v0.1.