Table of Contents 1. Application Overview____________________________________________________ 1 1.1. Identifying The Parts _________________________________________________ 1 1.2. The Power Supply ___________________________________________________ 2 1.3. Insert GPRS/3G/LTE SIM Card _________________________________________ 2 1.4. How to install the Control Panel ________________________________________ 3 1.5. Compatible with Climax’s SMS Editor ___________________________________ 3 2.
4.2.3. Help Arrived Mode _____________________________________________________________________ 27 4.2.4. Speech Reporting Method ______________________________________________________________ 28 4.2.5. Report Sequence ______________________________________________________________________ 28 4.3 Walk Test (Range Test) _______________________________________________ 29 4.3.1. In Learning Mode _______________________________________________________________ 29 4.3.2.
1. Application Overview 4. 1.1. Identifying The Parts RED HELP BUTTON (with backlight) — Back-lit disigned for easy access at night TOP VIEW — Backlight illuminates when off-hook — Backlight flashes during the waiting period until help arrives 5. Microphone 6. Speaker REAR VIEW 1. GREEN LED — ON: AC Power is ON. — FLASH every second: AC Power failure 7. — This slot is for inserting a SIM card. — FLASH every 2 seconds: Panel or Device Low battery 8. 9.
code error 11. DC Jack — DC 12V connection 1.2. The Power Supply 1A switching power 12. Battery Switch 13. Local Programming Telephone Unit Input — A special telephone cord to connect CTC-1052 and your phone unit for Local Programming (optional). An AC power adapter is required to connect to a wall outlet. Be sure only to use an adapter with the appropriate AC voltage rating to prevent component damage. A DC 12V output and 1A switching power is generally used to power CTC-1052.
Insert the SIM card with the chip side facing up. Push to the furthest extend, then press on the edge of the SIM card firmly to secure it. SIM Card will delete its SMS message whenever the CTC-1052 is powered on. To remove SIM card: Locating a suitable position for the Control Panel The Control accessible. The Control Panel should not be placed in a damp location, such as a bathroom.
2. Release the Green Reset Button at the voice prompt “Release the Green button, Ready to learn sensor.” CTC-1052 is now in learning mode and the Red LED will start flashing. 2. Learn-in the Devices There are two methods to learn in devices: command learning and local learning. The system can learn a total of 20 sensors. 3. Press the (Learn) button on the device or sensor. Voice Prompt: “(Name of Sensor) learned.” 2.1. Command Learning Command Learning: 1.
3.1.2. CTC-835 Programmer 3. System Configuration CTC-835 is a powerful programming tool (sold separetely) that features a built-in keypad and LCD display to help you to program the medical alarm panels effeciently and conveniently. It also features Once-for-All Uploading, which allows you program on a computer via the supplied Pilot software and you can then upload all the settings to the medical alarm panel simultaneously with a single mouse click. 3.1.
Step 1. Dial CTC-1052 and hang up after first 2 rings, wait for another 8-20 sec then call again. CTC-1052 will answer the call on the first ring. You will enter the Remote Programming Mode after the first ring from the 2nd call. 3.2. Programming Your 1052 Please make sure CTC-1052 is in Programming Mode (RED LED flashes continuously) before trying any CTC-1052 Command Functions. Please refer to section System Configuration, Entering Programming Mode. Step 2.
Follow the Command Steps to program your CTC-1052: Delete Telephone Number: Step 1. Enter Command number (DTMF Numeric Command, ex. (01), (02)…) Step 2. Press (#) to terminate the DTMF Command. Step 3. One short beep will be heard for successful Command entry. To delete the 1st Tel. number, enter (01) followed by (#), after one short beep, enter another (#). You can hear one beep from the telephone speaker that indicates the telephone number has been successfully deleted.
1st & 2nd Tel. #s (12) 1st & 3rd Tel. #s (13) 1st & 4th Tel. #s (14) 1st Tel & 5th GPRS. #s (15) 1st Tel & 6th GPRS. #s (16) 2nd & 3rd Tel. #s (23) 2nd & 4th Tel. #s (24) 2nd Tel & 5th GPRS. #s (25) 2nd Tel & 6th GPRS. #s (26) 3rd & 4th Tel. #s (34) 3rd GPRS. #s (35) 3rd Tel & 6th GPRS. #s (36) 4th Tel & 5th GPRS. #s (45) 4th Tel & 6th GPRS. #s (46) 5th & 6th GPRS. #s (56) 1st, 2nd & 3rd Tel. #s (123) 1st, 2nd & 4th Tel. #s (124) 1st , 3rd & 4th Tel.
or 0 on their phone set to reset to the original communication duration (set by Command #46). Command 20-24 Reporting Method Commands (20-24) are used to program the Alarm reporting method for each Tel. Number. Command (20): Program the same Alarm Reporting Method for all 4 Tel. Numbers. Command (21-24): Program the alarm reporting method for the 1st-4th Tel. Numbers respectively. To terminate the call, press (9) or RESET BUTTON on CTC-1052.
Command 32 Audible Fault Alert If the Green Reset Button is not pressed within the period set by Command 67 (Help Arrived Timer), CTC-1052 will send the alarm report to summon help again and inform the Monitoring Center that no help has arrived within the period set by the Help Arrived Timer. Command 33 (Help Arrived Signaling) has to be set as ON for Command 67 (Help Arrived Timer) to be activated.
Command 35 Command 38 Silent Mode Follow-On & Call-Back Function CTC-1052 can be selected to operate in Silent Mode. This will mute all normal operation warning beeps, guard time tone and key tone.
within 15 seconds. Otherwise, CTC1052 will disconnect the call automatically. Command 42 To terminate the call, press DTMF (9), (0) or Green Reset Button on CTC1052. This command is designed for any compatible sensor, except Fall Sensor (fall detection). If the 5-minute waiting period is up, CTC-1052 will automatically exit this waiting mode and return to idle mode. Guard Time Delay time is a time period programmed to delay alarm reporting.
Command 43 Periodic Test Call CTC-1052 can be programmed to make test calls periodically from (00) (no test call) to every (1) - (7) or 30 days: Function Selection Result (0) OFF (1) - (7) 1 - 7 DAYS (8) 30 DAYS Periodic Test Call will only function with telephone numbers assigned to Digital or SMS reporting method in Command 20-24.
Command 45 Command 46 Follow-On Mode Choice Follow-On Mode & Two-Way Period This Command is only available for Digital reporting with Command #38 set as (0) or (2). It is used to select the Follow-On Choice for CTC-1052 after it has made a report to the Monitoring Center.
Factory default is set as (1) 1 Hour. When the Off-Set Time is reset in programming Mode, the time of the Off-Set period will recalculate. Command 61 Check SIM Card PIN Code This option is used to check SIM card PIN Code. Off-Set time Report will be sent only once, and then the Control Panel sends Check-in Report according to setting of period test call, unless the Control Panel restarts or the Off-Set time is reset.
Example: if you want to raise the speaker card module is disabled during this time). volume to level 5 in the Two Way mode, please enter: 2*5 Step 2. Remove the old SIM card and insert a new SIM card. Please DO NOT remove the SIM card except when the Control Panel is turned off or is in local programming mode to prevent errors or malfunctions. Step 3. Setup the new SIM card PIN code using Command 62.
enter (telephone number) followed by (#). During this time period, a continuous series (1 beep every 0.5 second) of beeps will be emitted to alert user. If the number is successfully programmed, the telephone handset will emit one short beep. If a false alarm is triggered by a fall detection, it can be cancelled within the Guard Time Delay by pressing the Active Button of the Fall Sensor for 4 seconds. If the number is unable to be programmed, the Control Panel will emit one long beep.
Command 76 Command 78 Call Progress Tone Mobility Time Out Warning This command is used to turn on/off the When Mobility Time expires and no reset dialing tone of phone calls while making alarm reporting. signal is received, CTC-1052 will emit a long beep every 5 minutes in 30 minutes. This warning can be enabled or disabled. Function Selection Result (0) OFF (Disable) Function Selection Result (1) ON (0) Disable (1) Enable Factory default is (1), Enable.
within 20 seconds. If no signal is received within 20 sec, CTC-1052 will emit a long beep and automatically returns to Programming mode. Learning can only be completed within the signal reception range of CTC-1052. Step 3: CTC-1052 will emit 2 beeps to indicate that Silent Pendant is learntin successfully. If no signal is received within 20 sec, CTC-1052 will emit a long beep and automatically returns to Programming mode.
Command 98 Factory Default Reset 3.3. SMS Remote Programming To Reset CTC-1052 to factory default settings, enter (98) and then (#). After one short beep, continue by entering () and then end with another (#), one beep will be heard for termination. Prior to procced, please be reminded to change the language setting of your mobile phone to English. Step 1: Use your handset and go into the SMS edit screen.
Auto-Answer Numbers 4. Operation The Control Panel can program up to 2 AutoAnswer Numbers. If a user calls the Control Panel using an auto-answer number, the Control Panel will pick up the call and instantly open up a two-way communication with the caller. 4.1. Idle Mode When the system is in Idle Mode, CTC-1052 is ready to execute the following functions: The Control Panel will auto-answer calls from the auto-answer numbers and are unaffected by Command #31.
4.1.4. CTC-1052 Battery Disconnection CTC-1052 can detect the absence of battery in the following cases: Exit Programming Mode When the battery disconnection lasts for 10-15 minutes, CTC-1052 will report to the Monitoring Center and the GREEN LED flashes slowly. After the pre-set Timer expires, CTC-1052 will emit a long beep and voice prompt reminder “Inactivity timer expiring, please reset.” at every 5 minutes to notify the user for 30 minutes.
Step 3: Release the Reset Button when you hear the last long beep; a short beep will sound to indicate the mobility function is disabled. 0 = number to substitute After this is completed, Country Code “886” will be replaced by “0”. Please use Command #44 to enable the Mobility timer again. 4.1.8. Country Code The Phone Number Format for each SIM card may vary between different Telecom companies.
call” voice prompt, when fall detection has been cancelled. 4.2. Alarm Activation When an alarm is triggered, CTC-1052 will enter the Guard Time Delay period (see Command 42). Both Red LED and Red Help Button backlight will turn on. During the Guard Time period, pressing the Green Reset Button on CTC-1052 will stop alarm reporting and return to Idle Mode. If the Guard Time Delay is set as 00, CTC-1052 will dial immediately.
to set CMS IP Address(es) Commands: TCIP1 and TCIP2). (SMS Port Number: Central Monitoring Station server port number. Please refer to 5.5. CTC-1052 SMS Remote Programming Table on how to set Port Number(s) (SMS Commands: PORT1 and PORT2). GPRS/IP Account Number: There are 2 account numbers available for GPRS/IP reporting. Please refer to 5.5. CTC-1052 SMS Remote Programming Table on how to set GPRS/IP Account Number(s) (SMS Commands: IPAC1 and IPAC2).
If the speaker volume and microphone sensitivity was adjusted, the adjusted value will be kept for the next communication. Press any DTMF key, except the designated “hang-up” keys to reset the communication time to its preset duration. Please note that when a particular DTMF key is pressed, its designed shortcut function will be executed & the communication time will be extended at the same time. Pressing the Green Reset Button can also terminate the call.
UP or just put the handset back the base cradle. report, retry no more, and return to idle mode. into 2. SCANCOM FORMAT: Enter (1) to LISTEN-IN ONLY Enter (2) to TALK ONLY Enter (3) to open TWO-WAY VOICE COMMUNICATION End a Call: enter (5) or (0) to HANG UP or put the handset back into the base cradle. Enter (*) to TOGGLE 3.
If both Call-Back mode and Help Arrived mode are enabled, for the duration of Help Arrived mode, callback mode is always on and the Callback function is always available. The Monitoring Center can call CTC1052 as many times as possible until Help Arrived Mode is terminated. Calls established in help arrived mode can be terminated by pressing DTMF 9 or 0 on the caller handset or pressing the Green Reset Button on the Control Panel.
2. Control Panel will retry all destinations up to 15 times in total. 3. If more than 1 report destinations are set to a report method (e.g. Digital), the panel will consider the report method to be successful if reporting to one of the destinations succeeds. Control Panel will completely stop reporting to this report method after receiving a successful report. 4. report 4.3 Walk Test (Range Test) Walk Test, or Range test, is a test to check whether learned-in devices are within signal range.
4.3.3. In Idle Mode 4.4 Global Test Idle Mode is only applicable to Smoke Detector (SD), Carbon Monoxide Detector (CO), Motion Sensor (IR), and Water Sensor (WS). Global Test is used to test if the complete system is working properly. To do the Global Test: Step 1. Press the Test button of the devices mentioned above (SD, CO, IR, WS), and a signal will be sent to CTC-1052 indicating it is ready to conduct Walk Test. Step 1. Press the Green Reset Button once. Step 2.
111 - Smoke emergency 5. Appendix When the Smoke Detector (SD) is 5.1. CID Event Code triggered. When the Test Button of the Smoke The message composition for CID Event code is in the form: Detector (SD) is pressed. ACCT MT QXYZ GG C1C2C3 120 - Fall emergency When Fall Sensor is triggered And is explained in the following table: 147 - Sensor Supervisory Failure Where ACCT = 4 Digit Account number (0-9) MT = Message Type, 18H.
When other devices are under Low 5.2. Tunstall Event Code Battery Status, the Green LED flashes every 2 seconds D#1011 - Panel AC Restored/ Help Arrived 602 - Periodic test report When AC power is restored to CTC- When CTC-1052 reports Periodic test 1052. call to monitoring Center. When CTC-1052 makes Help Arrived 606 - Follow-On Function reporting. When CTC-1052 receives kiss-off from D#1012 - Global test & Periodic test Monitoring Center for opening Speech channel.
555556558 - Panel Low battery / Panel Detector’s test button is pressed. Battery Disconnection D#1019 - Panel AC Failure When CTC-1052 is under Low Battery When AC power fails for more than 10 status, the Green LED flashes every 2 seconds. seconds, Green LED flashes every second with a beep every 30 seconds. When CTC-1052 is under Battery Not D#1019 – Panel Low Battery / Panel Connected status, the Green LED flashes every 2 seconds.
When the device Low Battery status, is restored. 155555517 - SD or CO emergency When Smoke Detector (SD) is triggered or Smoke Detector’s test button is pressed. When Carbon Monoxide Detector (CO) is triggered or Carbon Monoxide Detector’s test button is pressed. 355555557 - SD or CO emergency restore When the Smoke Detector (SD) or Carbon Monoxide Detector emergency status is restored. (CO) FCC Statement This device complies with Part 15 of the FCC Rules.
5.4.
DTMF DTMF CHARACTER COMMANDS ACK 44# Bi 45# Bi 46# Bi 47# Bi 49# Bi 61# Bi 62# Bi COMMAND OPERATION Mobility time 00= Disable, 01 - 36= 1 - 36 Hours Follow-On Choice, 0 = Wait command, 1 = Listen, 2 = Two way voice communication Follow-On mode & Two-Way Period, 01=1 min, 02=2mins, 03=3mins, 04=4mins, 05=5mins, 06=6mins, 07=7mins, 08=8mins, 09=9mins, 10=10mins.
5.5. CTC-1052 SMS Remote Programming Command Table If the SMS Keyword is set as PROG, and Access Code is set as 1111 (factory default).
31# Ringer enable for incoming calls ENRIN 32# Audible fault alert FAUTA 33# Help arrived signalling HELPA 34# Emergency button EMBUT 35# Silent mode SILMO 37# AC fault report ACRPT 38# Follow-On & Call Back FOLON 40# Set access code ACCES 42# Guard time delay GUDTI 43# Periodic test call TESTC 44# Mobility timer MOBTI 45# Follow-on choice LFOLL 46# Follow-on & two-way period FOLTI 47# Off-set time 49# Supervision 61# Check SIM card Pin code 62# Input SIM card P
PROG 1111 SPKVL:2&1-5 To set a communication channel: 2=Two 63# Set speaker volume SPKVL 64# Set microphone sensitivity MICSN 66# Set guard time for fall sensor FAGUD 67# Set Help Arrive Timer HTIME 71# 72# AutoAnswer Number 1 AutoAnswer Number 2 CTEL1 CTEL2 75# Help Not Arrived Call HTEL1 77# Speech report ack SPACK 78# Mobility Timeout Prompt MOBBP --- Country code REPLA --- IP address TCIP1 --- IP address TCIP2 --- IP address confirm COMIP --- Port number PORT1 -
Reset to factory default 3G/LTE RSSI (3G Version Only) --- --- Delete Device --- FTSET PROG 1111 FTSET:YyS GRSSI PROG 6336 GRSSI? DEVDL --- Add Device DEVAD --- Get Current Panel Settings (3G Version Only) ULOAD PROG 1111 DEVDL:SCMD To delete devices learnt into the panel. SCMD: 80 = delete All Devices.
message sent by the cell phone. 3. SMS remote programming command can only be sent in the standby mode. 4. The SMS command is successfully set after getting a confirmation message.
Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15, Part 22, Part 24, and Part 27 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Industry Canada Statement This device complies with Industry Canada RSS-130, RSS-132, RSS-133, RSS-139 standard. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le pr ésent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.