c August 12, 2013
Table of Contents 1. Application Overview________________________________________________________ 1 1.1. Identifying The Parts ____________________________________________________________ 1 1.2. The Power Supply ______________________________________________________________ 2 1.3. Line Capture____________________________________________________________________ 3 1.4. How to install the Control Panel __________________________________________________ 3 2.
5. Appendix __________________________________________________________________ 29 5.1. CID Event code ________________________________________________________________ 29 5.2. Tunstall Event code ____________________________________________________________ 30 5.3. Scancom Event code ___________________________________________________________ 30 5.4.
— Press & hold for 16 sec: disable 1. Application Overview mobility setting 1.1. Identifying The Parts TOP VIEW 4. RED HELP BUTTON (with backlight) — Back-lit disigned for easy access at night — Backlight illuminates when reporting and off-hook — Backlight flashes during the waiting period until help arrives 1. GREEN LED 5. Microphone 6. Speaker — ON: AC Power is ON.
BACK VIEW 12. Mounting Holes 13. Mounting Bracket 1.2. The Power Supply An AC power adapter is required to connect to a wall outlet. Be sure only to use an adapter with the appropriate AC voltage rating to prevent component damage. A DC 12V output and 1A adapter is generally used to power CTC-1041RV. In addition to the adapter, there is a rechargeable battery inside CTC-1041RV, which serves as a back-up in case of a power failure.
1.3. Line Capture 1.4. How to install the Control Panel CTC-1041RV features Master Control over the telephone line. That means, even if the phone line is engaged, the CTC1041RV has the power to circumvent the line and dial-out anyway. Locating a suitable position for the Control Panel The Line Capture feature is only available when household phones are connected after the CTC-1041RV wiring. The Control Panel requires main power and a constant telephone connection.
WTRVS, CP-23 or CTC-808RV learned in via Command 93 does not provide silent reporting (they provide two-way communication). 2. Learn-in the Devices There are two methods to learn in devices: local learning and command learning. Total 10 sensors are allowed to be learnt into the system. The combined numbers of DECT devices (WTRVS, CP-23 and CTC-808RV) learned into CTC-1041RV can be up to 4. 5.
devices in Zone 1 and Zone 2 have been simultaneously removed. Now you can learn DECT devices into Zone 1 and Zone 2. For Normal Wrist Transmitters (WTR-) or Fall Sensor 1. Press and hold the RESET button of CTC1041RV for 6 seconds until you hear the double beep and followed by a long beep. 2. The RED LED starts flashing. CTC1041RV is now in the learning mode. 3. Press and both the HELP and Pendant #1 (WTR- Series or Fall Sensor) buttons simultaneously until CTC-1041RV emits a double-beep. 4.
indicate there are still empty zones for DECT devices. If CTC-1041RV has learned 4 DECT devices and there are no more zones for DECT devices, the red LED will flash quickly. You can clear Zone 1 and Zone 2 for DECT devices to be learned in by pressing and holding CTC-1041RV’s green reset button for 6 seconds until you hear a long beep that indicates the devices in Zone 1 and Zone 2 have been simultaneously removed. Now you can learn DECT devices into Zone 1 and Zone 2.
The two options are set by Command #41. Please refer to Command 41 under section 3.2 Programming your 1041RV. 3. System Configuration 3.1. Entering Programming Mode 3.1.2.1. Auto Answering by Ring Count Three CTC-1041RV programming modes are available: Local Programming Mode, Remote Programming Mode, and via CTC-835 Handheld Programmer (sold separately). 3.1.1.
3.2. Programming Your 1041RV To exit Remote Programming mode, enter 99 followed by #. How to enter Commands? 3.1.3. CTC-835 Programmer Please make sure CTC-1041RV is in Programming Mode (RED LED flashes continuously) before trying any CTC1041RV Command Functions. Please refer to section System Configuration, Entering Programming Mode.
Step 4. Enter the desired Command function number. Command 05-06 Select Telephone Number for Alarm Reporting and Status Reporting Step 5. Enter (#) to terminate the Command Operation. Step 6. CTC-1041RV will emit a short beep, indicating successful programming. If the Tel. number is selected in Commands #5, #6 and #7, then Command #7 holds the top priority to overwrite the setting. The Tel.
Command 10-14 The Tel. number selected in Command #7 will not be used for alarm and/or status reporting, even if it is selected in command #5 and/or #6. Account Number Programming When multiple Tel. numbers are selected, CTC-1041RV will always dial in respective programmed order. Command (10): Set the same account Commands (10-14) are used to set the account number for the telephone numbers used for Digital Reporting. number for all telephone numbers.
will automatically enter specific Follow-On and/or Call Back Mode as specified by Command (38). If Speech Method is selected: After the dialing for alarm/emergency trigger is successful, CTC-1041RV opens a two-way voice communication between the Call Recipient and CTC1041RV for 1-10 minutes (set by Command #46). To terminate the incoming call: (1) press the green reset button on CTC1041RV; or, (2) press DTMF #9 from the call recipient’s end.
Function Selection (0) activated. When pressed, it will send an Emergency alarm report to the Monitoring Station. Result OFF (Disable) ON (1) Command 35 (Enable) Silent Mode Factory Default is set as (1), ON. CTC-1041RV can be selected to operate in Silent Mode. This will mute all normal operation warning beeps, key tone and ring.
between WTRVS, the Monitoring Center and all CTC-808RVs learned into the system. Command 38 Follow-On & Call-Back Function The Command is available for Digital If the alarm is triggered by CTC-808RV, the system will wait for an authorized access code (default 1111) followed by (#) during the 5-minute waiting period to open two-way communciation between the Monitoring Center and all CTC-808RVs learned into the system. Reporting Methods (when Command #20 #24 is set as (0), (1) or (2).
The first digit of Access Code must be entered within 15 sec. Otherwise, CTC-1041RV will disconnect the call automatically. To terminate the call, press DTMF (9) or RESET BUTTON on CTC-1041RV. If the 5-minute waiting period is up, CTC-1041RV will automatically exit this waiting mode and return to idle mode. Command 41 During two-way communication, you can use DTMF command to switch the communicating method. Please refer to section 4.2. Alarm Activation.
reporting with Command #38 set as (0) or (2). Command 44 Mobility Timer This function monitors user movement around the premises and sends an inactivity report to the Monitoring Center if the user fails to reset the inactivity timer. It is used to select the Follow-On Choice for CTC-1041RV after it has made a report to the Monitoring Center.
If an alarm is triggered by WTRVS or CTC-808RV, Monitoring Center personnel will have to press DTMF 2 for over 1 second to open two-way communication regardless of the Follow-On choice you have set.
methods. The supervision function does not cover WTRVS. The Help Arrived function (Command 33) must be set as ON for this function to work. Command 66 Set Guard Time Delay Time for Fall Sensor Command 75 This command is used to set the guard When CTC-1041RV has sent an alarm Help Not Arrived Call time delay time for fall sensor. alarm reporting (triggered by Fall Sensor) from (00) (instant reporting) to (99) seconds.
in before. To remove a talking pendant (WTRVS) or CTC-808RV from the Contorl Panel, you have to remove it from the Control Panel first and then restore the WTRVS or CTC-808RV to factory default. Commands 92 Learn-In Pendant #2 Only one Pendant can be learnt into CTC- If the Pendant(s) you use Commands 80-84 to remove includes any WTRVS or CTC-808RV, you will need to wait 5 to 10 seconds for the system to emit an acknowledging beep over the phone. 1041RV by using Command #92.
a short beep will be heard via the phone set. Pendant, CTC-1041RV will not emit any warning beeps during Reporting. For learning Silent Pendant: Step 2: Press the learn button on the device within 60 sec. Step 1: Enter 93 + # on the phone set, then a short beep will be heart via the phone set. Step 2: Press the Pendant Button within 60 sec. Learning can only be completed within the signal reception range of CTC-1041RV.
Enter (99) and (#), after one short beep, 4. Operation CTC-1041RV exits the Programming Mode and returns to idle mode. 4.1. Idle Mode When the system is in Idle Mode, CTC1041RV is ready to execute the following functions: 4.1.1. Auto-Answer Incoming Phone Calls This function is only available when Command #31 is set as ON (factory default is OFF). For an Incoming telephone call, CTC1041RV will emit cycles of 2 quick beeps.
Step 4. At the last 20 & 10 sec, CTC- 1041RV will emit two beeps via the telephone handset to alert the call recipient. If the Call Recipient needs more conversation time, press any DTMF key (except 9) can add another 1 to 10 minutes (set by Command 46). 4.1.2. Non-Emergency Speech Call This function is only available when Command #7 is programmed. Making a Non-Emergency Call from CTC1041RV Step 1. From Idle mode, press and hold the RESET button for 3 seconds until CTC-1041RV emits a short beep.
battery in the following cases: Battery switch OFF Battery not connected Battery failure. 4.1.8. Mobility Timer In order to check the user’s well being, a Mobility Timer can be set by using Command #44. If Mobility Timer is set as Enable, a counting down period starts from: When the battery disconnection lasts for 10-15 mins, CTC-1041RV will report to the Monitoring Center and the GREEN LED flashes slowly.
4.1.9. No Pendant Present This function is only available for the digital Contact ID reporting method. If there is no pendent being learnt into CTC-1041RV 30 minutes after powering up, it will send a No Pendant Learnt-in report to the Monitoring Center and repeat every hour thereafter, until a pendant is successfully learnt in. Alarm Triggered (WTRVS) The control panel will still send No pendant Learnt-in report even when 1041RV is only Learning WTRVS.
directly. When an alarm reporting successfully goes through to CMS but no DTMF command is received by a CTC808RV, connection time will be up after 2.5 minutes. When the reporting to CMS fails, CTC-808RV will enter the retry cycle until it receives a DTMF command. CTC-808RV’s communication function is temporarily suspended when CTC1041RV is engaged in two-way communication.
Enter (0) to hang up the call only. Help arrived mode and callback mode will continue. WTRVS and/or CTC-808RV will remain in callback mode. f levels of speaker volume can only be adjusted in the two-way or talk only communication mode, the adjusted value will be kept at next use. The value of speaker volume ranges from 1 to 8 and the default value is set as (5). The value of speaker volume ranges from 1 to 8 and the default value is set as (5).
During Two-way Voice Communication, at 20 & 10 seconds before the Follow-On period expires, CTC-1041RV will emit two beeps to alert both the user and the Monitoring Center Personnel. To extend the conversation, the Monitoring Center personnel can press the DTMF command again to add another 1-10 mins. by Command 75 and open two-way communication when the call is answered. If the call is not answered, CTC-1041RV will end the report, retry no more, and return to idle mode.
way communication is terminated by pressing DTMF 9, the control panel will simultaneously end help arrived mode and send event code 1663 to report the cancelled help arrived mode. If the twoway communication is terminated by pressing DTMF 0, the control panel will remain in help arrived mode. Speech Reporting Method If Speech Reporting Method is selected, after dialing, CTC-1041RV will open a twoway voice communication between the Call Recipient and CTC-1041RV for 1-10 minutes (set by Command #46).
Center. determine the operation range of the devices. Step 1. From Idle mode, press and hold the RESET button for 6 seconds. Once pressed, a button beep sound will be heard. CTC-1041RV will emit one short beep at 3 sec., then a double beep when it reaches 6 sec. This function is for WTR only, not for WTRVS. 4.5. Factory Reset CTC-1041RV will clear all programmed parameters by the following sequence: Step 2. Release the button after you heard the double beep.
373 - Smoke Low battery 5. Appendix When Smoke Detector is under Low 5.1. CID Event code Battery Status, Green LED flashes every 2 sec with 3 beeps every hour. 100 - Panel emergency 380 - WTR Low Battery When the red HELP Panel button is When Wrist Transmitter (WTR) or pressed. Emergency Pendant is under Low Battery Status, Green LED flashes every 2 sec with 3 beeps every hour.
When a fall sensor is triggered. for four times. D#1017 - Panel emergency 662 – Nurse needs help When the RED HELP Panel button is When the nurse needs more help and presses the red help button to call for assistance. pressed. When Water sensor is triggered. 663 – Helped arrived mode canceled D#1018 - Smoke emergency When the green reset button is pressed twice in help arrived mode to cancel help arrived mode. When Smoke triggered.
When Pendant 1 and Pendant 2 Restore / WS Emergency Restore buttons are pressed together. When the WTR supervision failure When the Red Help Button and status is restored. Pendant 2 button are pressed together. When WS restored. 515555157 – Help arrived mode emergency status is 555555558 - Device Low Battery When help arrived mode is activated.
5.4.
DTMF DTMF CHARACTER COMMANDS ACK 43# Bi 44# Bi 45# Bi 46# Bi 47# Bi 49# Bi 66# Bi 67# Bi 75# COMMAND OPERATION Test call, 0 = OFF, 1 = 1 Day, 2 = 2 Days, 3 = 3 Days, 4 = 4 Days.
FCC statements Changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.