Introduction The new Pro-Vue Interactive provides a whole new dimension to interactive teaching and presentation; all the benefits of an interactive whiteboard...
Accessories Introduction Function of the “E-Wand” When the silver button on the E-Wand body is pressed, an infrared signal is emitted, which is detected by the IR Sensor integrated within the Projector (when the button is pressed and an IR signal emitted, the LED on the E-Wand lights red). LED Lamp Button: Mouse Left Key Before using the Wand. Screw the Telescopic Rod into the Wand body firmly. How to use: 1) Extend the telescopic E-Wand to the required length.
Good Practice use of the E-Pen & E-Wand when presenting/teaching: Please note that as the Pro-Vue functions using infrared light, a ‘line-of-sight’ between the E-Pen/E-Wand and the Projector is essential for effective use. Therefore, good-practice use requires the presenter/teacher to ensure the E-Pen/E-Wand is used out of any shadow area, which may occur dependent on your positioning of the projector to screen.
Operation Guide for Windows OS Interactive function is provided by “LightPenII” software. 1. System Requirements To ensure the interactive functions of your Pro-Vue Projector work properly, please check your computer to ensure it meets the following specifications. Note: for Windows Vista (a) Click mouse right key on “LightPenII.exe” or the short-cut icon for “LightPenII.exe” and then click mouse left key to select “Properties”.
3. Initial Setup for Interactive Function 3.1 Connect the supplied USB & VGA cables between Pro-Vue projector and PC. 3.2 Execute the “LightPenII” software by double-clicking the “LightPenII.exe” or the short-cut icon for the “LightPenII.exe”. Then the icon for the “LightPenII” appears in the task bar and the tool bar appears on the right side of the screen. 3.3 Select Distance Step 1: Click left mouse button on the “LightPenII” in the task bar. Step 2: Select “Projection Distance”.
3.4. Calibration 3.5 StartUp Step 1: Click the left mouse button on the “LightPenII” in the task bar. Step 1: Click the mouse left key on the “LightPenII” icon in the task bar. Step 2: Select “Calibration”. Step 2: Select the “StartUp”, then the “ 4 ” mark appears in the pop-up menu. Step 3: Push the button on the “E-Wand” or press the tip of the “E-Pen” on the center of each green target. The colour of target changes black from green as it appears.
4.
In Mouse Mode (default) By selecting ‘Mouse’, ‘Mouse Right Click’ or ‘Mouse Double Click’ from the Lightpen Toolbar, the E-Pen and E-Wand will fully interact with all your standard software, functioning as would a standard mouse.
Shortcut switch between ‘Mouse’ and ‘Pen’ modes: Switching between Mouse and Pen mode can be quickly and easily done by clicking the E-Pen/E-Wand on the top or bottom edge of the ‘screen’ slightly outside of the projected image. When Mouse mode selected, When Red Pen mode is selected, 10 icon is shown in the task bar. icon is shown in the task bar.
5. How to close Interactive function 5.1 Select “Mouse” mode by clicking “Mouse” icon in the tool bar. 5.2 Click the mouse left key on the LightPen icon in the task bar. 5.3 Click the mouse left key to select “Exit”. 5.4 Click ‘OK’.
Operation Guide for Mac OS Interactive function is provided by “LightPen” software. 1. System Requirements To ensure the interactive functions of your Pro-Vue Interactive Projector work properly, please check your computer to ensure it meets the following specifications. System Requirements OS Required Mac OS X v10.4.11- v10.
3. Initial Setup for Interactive Function 3.1 Connect the supplied USB and VGA* cables between Pro-Vue projector and the PC. 3.2 Execute “LightPen” software by clicking the “LightPen” or the shortcut icon for the “LightPen”. The icon for “LightPen” appears in the task bar and the tool bar appears on the right hand side of the screen. * (Requires Apple Mini DVI to VGA Adapter) 3.3 Select Distance Step 1: Click the mouse key on the “LightPen” in the menu bar.
3.4 Calibration Step 1: Click the mouse key on “LightPen” in the task bar. Step 2: Select the “Calibration”. Step 3: Push the button on the E-Wand or press the tip of the E-Pen on the center of each green target. The colour of target changes black from green. The next green target appears on the upper middle area of the screen. Repeat the same until all 9 targets change black.
4.
Troubleshooting 1. Q: Why does it show “No LightPen found”? Reasons for this might be: 1 The USB cable is not properly connected. Check cable connections at computer and Pro-Vue Projector. Should the Lightpen icon appear with a red cross in your Toolbar, the USB cable may have been disconnected at computer/projector. Check connections are correct and secure. * Some Anti-virus programs will disable the USB port. Please make sure the USB port is not disabled.
3. Q: The cursor is not at the same position as the E-Pen/E-Wand is pointing: Possible reasons for this are: 1 The system is not calibrated well. Try to point to the “center” of green cross target when you run calibration. 2 The position of the projector, screen or projection size has been changed. 3 The image resolution has been changed. Running the calibration procedure again will solve the problem. 4.
Take a look at our new website for details on our full range of Clever Little Box products at: CIE-Group Widdowson Close Blenheim Industrial Estate Bulwell Nottingham NG6 8WB T: 0115 9770075 F: 0115 9770081 E: info@cie-group.com W: www.cie-group.