HDAVS IR Motorized Vari-focal Vandal-proof Dome Camera User’s Manual Version 1.0.
Table of Contents 1 General Introduction .................................................................................................................. 1 1.1 Overview ........................................................................................................................ 1 1.2 Features ......................................................................................................................... 1 1.3 Functions .............................................................
Welcome Thank you for purchasing our HDAVS camera! This user’s manual is designed to be a reference tool for your system.
Important Safeguards and Warnings 1.Electrical safety All installation and operation here should conform to your local electrical safety codes. The power shall conform to the requirement in the SELV (Safety Extra Low Voltage) and the Limited power source is rated 12V DC in the IEC60950-1. We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation.
Please shut down the device and then unplug the power cable before you begin daily maintenance work. Use the dry soft cloth to clean the device. If there is too much dust, please use the water to dilute the mild detergent first and then use it to clean the device. Finally use the dry cloth to clean the device. Please put the dustproof cap to protect the CMOS component when you do not use the camera.
Applicable model This manual can be applied to following model: HD2-TD27 v
1 General Introduction 1.1 Overview This series megapixel HD camera conforms to the HDAVS standard. It supports video signal high-speed long distance transmission without any delay. It can be controlled by the DVR conforming to the HDAVS. 1.2 Features High-performance CMOS image sensor, megapixel definition. Default motorized vari-focal lens, adopt auto focus technology, support coaxial cable to control lens zoom and focus.
Smart IR technology The sensor controls the IR light on/off via the combination work of the hardware and software, which realizes the automatically IR light compensation according to the environment illumination. 3D NR Comparing with the general 2D denoise function, the 3D denoise function can not only denoise the brightness of the video separation signal and saturation signal, it can also denoise the original data from CCD.
2 Framework and Dimensions Please refer to the following figures for dimension information. The unit is mm. See Figure 2-1 to Figure 2-3. Figure 2-1 Figure 2-2 When the standard definition/high definition switch control cable is short circuit, system outputs standard definition video. Otherwise, when the circuit is open, system outputs the high definition video.
3 Installation Important Before the installation, please make sure the installation surface can sustain at least 3X weight of the bracket and the camera. The dome camera usually uses the ceiling installation. It can be installed on the ceiling or the wall. Please refer to Figure 3-1 for installation hole site. For side exit cable installation, please make sure the side exit cable direction is the same as shown in the installation position map.
Figure 3-2 Step 1 Take the installation position map from the accessories bag and then put it on the surface of the ceiling or the wall according to the cable exit position. Dig three holes according to the installation position map and then take three expansion bolts from the accessories bag and put them to the holes you just dug. Step 2 Use inner hex wrench to remove the three case locking screws and then remove the dome enclosure.
Step 5 Use three case locking screws to secure the dome housing on the pedestal. Now you have completed the device installation and cable connection. , You can use the terminal encode devices to view the monitor video.
4 Menu 4.1 HDAVS Series DVR Settings Note The following operation and interfaces for reference only. Please refer to the HDAVS series DVR user’s manual for detailed information. After connected the camera to the HDAVS series DVR, from Main Menu->Setting->System>PTZ, you need to set control mode as HDAVS and the protocol as DH-SD1. Click Save button to save current setup. See Figure 4-1. Figure 4-1 On the preview interface, right click mouse and then select PTZ; you can see an interface shown as below.
Click Iris “-” to realize auto focus. Click up/down button to view all the items on the left pane of the following list. Click left/right button to set the corresponding values on the right pane of the following list. If there is “ ”, click confirm button to go to the 2nd menu. Repeat the previous steps to set detailed value. Click Return button to go back to the previous menu interface. Click Zoom “+” to zoom in and click Zoom “-” to zoom out. 4.
Appendix Toxic or Hazardous Materials or Elements Component Name Toxic or Hazardous Materials or Elements Pb Hg Cd Cr VI PBB PBDE Circuit Board Component ○ ○ ○ ○ ○ ○ Device Construction Material ○ ○ ○ ○ ○ ○ Wire and Cable ○ ○ ○ ○ ○ ○ Packing Components Accessories ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ O: Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ/T11363-2006 standard.