User's Manual
RF-MDWS-HP-S—Installaon Instrucons
Wireless Sensor and Accessories
1 - RF-MDWS-HP-S Sensor 1- Mounng Tape 1 - Magnet 1 - Baery ( 3VDC CR 2) Instrucons
Tamper
switch
Doc # I-RF-MDWS-HP-S Rev A. Mar 2017
Installaon
1. Remove the transmier’s cover by pressing in on
the small rectangular latch on the end of the cover
and li up
2. Mount the sensor base directly to the surface us-
ing the mounng tape provided. Make sure to
align the mounng tape with the tamper pull put
area on the boom of the sensor to insure proper
tamper operaon.
3. Mount the magnet next to the sensor and align
the magnet with the mark on the side of the sen-
sor, using the mounng tape provided, or connect
an external contact to the terminals
4. Remove the baery isolator tabs from both baer-
ies on the sensor
5. Replace the cover on the transmier
6. Enroll the senor into the control panel according
the instrucons
Note: Mounng the transmier onto metal surfaces
may impact the eecve range of the transmier
Cover
Latch
Cover
Latch
Tamper
Base
Note: Baery Safety
Observe polarity when inserng
replacement baery to avoid damag-
ing the sensor.
Risk of re, burns and explosion. Do
not recharge, disassemble, burn or
expose baeries to temperatures
above 100C (212F)
Dispose of used baery properly and
in accordance with all local laws
Keep baeries away from children
Baery
RF-MDWS-HP-S—Installaon Instrucons
Wireless Sensor and Accessories
1 - RF-MDWS-HP-S Sensor 1- Mounng Tape 1 - Magnet 1 - Baery ( 3VDC CR 2) Instrucons
Tamper
switch
Doc # I-RF-MDWS-HP-S Rev A. Mar 2017
Installaon
1. Remove the transmier’s cover by pressing in on
the small rectangular latch on the end of the cover
and li up
2. Mount the sensor base directly to the surface us-
ing the mounng tape provided. Make sure to
align the mounng tape with the tamper pull put
area on the boom of the sensor to insure proper
tamper operaon.
3. Mount the magnet next to the sensor and align
the magnet with the mark on the side of the sen-
sor, using the mounng tape provided, or connect
an external contact to the terminals
4. Remove the baery isolator tabs from both baer-
ies on the sensor
5. Replace the cover on the transmier
6. Enroll the senor into the control panel according
the instrucons
Note: Mounng the transmier onto metal surfaces
may impact the eecve range of the transmier
Cover
Latch
Cover
Latch
Tamper
Base
Note: Baery Safety
Observe polarity when inserng
replacement baery to avoid damag-
ing the sensor.
Risk of re, burns and explosion. Do
not recharge, disassemble, burn or
expose baeries to temperatures
above 100C (212F)
Dispose of used baery properly and
in accordance with all local laws
Keep baeries away from children
Baery