Installation Manual

ClareOne Glass Break Detector Installation Manual
CLR-C1-GB
CLR-C1-GB IM V1 06112020
Product Description
ClareOne Glass Break Detector CLR-C1-GB is a robust Wireless Glass Break Detector which has alarm,
tamper, and low battery signal outputs.
Setup Instructions
Test Mode: Remove the insulation tabs from the battery holder, test mode is activated for 5
Minutes upon
power on. LED blinks every second when detector is in test mode.
Detector will exit test mode after 5 minutes.
Sensitivity (Range)Table below for detail sensitivity setting.
SENSITIVITY
DETECTION RANGE
SW 1-1
SW 1-2
MAX 6 M OFF OFF
MEDIUM 4M OFF ON
LOW 2.5M ON OFF
LOWEST 1.5M ON ON
LED Indicators Table below summarizes the LED messages
Bottom Cover
Mounting Hole
Tamper Switch Hole
Mounting Hole
Battery Insulation
Battery
Tamper Switch
Middle Cover
DIP Switch
Lock
SW1-2
SW1-1
CONDITION RED LED
Power Up Flash 3 times, flash once per second
Test Mode, event detected Flash once per second (slow flashing)
Test Mode, alarm Flash 2 seconds (quick flashing)
Working, Alarm ON 5 seconds
Low Battery Flash once every 30 seconds
Top Cover
LED Indicator