Installation Manual

Table Of Contents
ClareOne Panic Keyfob Installation Manual
CLR-C1-PNC
CLR-C1-PNC IM V3 05012020
Description
The CLR-C1-PNC is a lithium battery (replaceable) powered operated panic device for an alarm system. The Panic
provides the user: (specific programming required for operation)
Police alarm sounds.
Medical reporting.
Silent alarm reporting.
Auxiliary (local only sounds).
Programming
The following steps describe the general guidelines for programming the sensor into panel memory. Refer to the
specific panel’s documentation for complete programming details.
Note: In programming, the sensor should be enrolled in a supervised group, this maintains integrity between the panel
and device.
Enter panel learn-in/enrollment mode.
1. Select sensor number.
2. Select sensor type (specific for panel).
3. When the panel request sensor activation.
4. Press the Panic button 2 times within 1 second.
5. Exit program mode.
Testing and the Sensor
Sensor should be tested for both operation and range.
Operational Testing
Press the Panic button 2 times within 1 second, the specific alarm sound should immediately sound.
Disarm the system to silence the alarm.
Wireless Testing
Wireless testing provides a baseline for the distance the panic will operate away from the control panel.
Enter dealer sensor test at the control panel.
Press the Panic button 2 times within 1 second and verify panel acknowledgement.
Walk away from the panel and test at various locations making sure the panel acknowledges.
Note: Non-supervised sensors should be tested weekly to ensure proper operation.
Battery Replacement
Note: If a low battery alarm occurs, replace the battery within 7 days.
The CLR-C1-PNC requires (1) 3-VDC, lithium coin-cell batteries (Varta or Panasonic, Model CR2032),
1. Remove the cover
2. Remove the circuit board
3. Observe polarity when replacing battery.
CAUTION: Battery may explode if mistreated. Do not recharge, disassemble, or dispose of in fire.