Installation and Commissioning Procedure For iSLC3100-7P-N CIMCON Lighting, Inc. ISLC3100-7P-N Place the Photocontroller into the 7-pin NEMA receptacle and rotate it clockwise to lock. Fig.
Installation Procedure ISLC3100-7P Fig.
Installation Procedure ISLC3100-7P The cables protruding from the receptacle have following function as mentioned into table. Once the Photo-controller is installed and luminaire is powered ON then depending on the daylight condition Lamp will operate. In the Lab environment, you can just cover the cap with cloth or by hand and see the Lamp turning ON if wired correctly and if you remove the cloth, it will turn OFF.
Installation Procedure ISLC3100-7P iSLC SIM CARD NBIOT node comes with either ESIM configuration or Normal SIM configuration ESIM configuration: - ESIM will be solder on bottom of RF board with this configuration Normal SIM configuration: - For Normal SIM user need to arrange Micro SIM card and need to insert into module as per below.
Installation Procedure ISLC3100-7P Normal SIM Configuration Micro Size Sim Card Page 5
Installation Procedure ISLC3100-7P LED indication on RF board LED Indication chart Flicker slowly (200 ms High/1800ms Low) Network searching Flicker slowly (1800 ms High/200ms Low) Idle Flicker quickly (125ms High/125ms Low) Data transfer is ongoing Always high Voice calling Page 6
Installation Procedure ISLC3100-7P Safety Consideration for the Installation crew: Ensure that the supply voltage matches the SLC’s voltage rating. Firmly place the SLC into the NEMA twist lock receptacle/socket on top of the fixture by aligning the large prong on the SLC with the large opening in the receptacle/socket. Push down on SLC and twist clockwise until it locks into place.
Installation Procedure ISLC3100-7P FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules.