Product Manual RF Module No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of CIMCON Lighting, Inc. Information in this document is subject to change without notice. CIMCON Lighting, Inc. may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights covering subject matter in this document.
Product Manual RF Module Table of Contents 1 1.1. 1.2. 1.3. 1.4. 2 3 3.1. 3.2. 3.3. 3.4. 4 5 GETTING STARTED ............................................................................... 1-1 OVERVIEW ......................................................................................................................... 1-1 KEY FEATURES ................................................................................................................... 1-1 FCC APPROVALS ...............................
Product Manual RF Module 1 GETTING STARTED 1.1. Overview This manual describes the key features, pin out, recommended operating conditions, working of RF module and operating instructions to test the module for FCC. CIMCON RF modules are designed to operate within the ZigBee protocol and support the unique needs of low-cost, low-power wireless sensor networks. The modules require minimal power and provide reliable delivery of data between remote devices. The modules operate within the ISM 2.
Product Manual RF Module 1.3. FCC Warnings and Labeling Warning: This device is intended only for OEM integrator under the following conditions: 1. The antenna must be installed such that 20 cm is maintained between the antenna and users, and 2. The transmitter module may not be co-located with any other transmitter or antenna, 3. For all products market in US, OEM has to limit the operation channels in CH11 to CH25 for 2.4G band by supplied firmware programming tool.
Product Manual RF Module 2. Zigbee MODULE PIN-OUT Following is the pin out of CIMCON RF module with description of each pin This information is confidential and proprietary to CLI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CLI is not permitted.
Product Manual RF Module Pin Descriptions: PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 SIGNAL 3.3V nReset PC6 OSC32B nTX_ACTIVE PC7 OSC32A OSC32_EXT PA7 TIM1C4 TIM1C4 REG_EN PD1 SC3MISO SC3MOSI SC3SDA SC3TXD GND PD2 SC3MISO SC3MOSI SC3SCL DIRECTION Power I I/O I/O O I/O I/O I I/O O I O I/O I O I/O O Power I/O I O I/O DESCRIPTION Used to power the CIMCON RF module. Active Low chip reset (Internal pull up) Digital I/O 32.768 KHZ CRYSTAL OSCILLATOR Inverted TX_ACTIVE signal Digital I/O 32.
Product Manual RF Module PIN 14 15 16 17 18 19 20 21 22 23 24 25 SIGNAL SC2SDA SC2MISO SC2MISO GND PA2 TIM2C4 DIRECTION I/O O I Power I/O O TIM2C4 I SC2SCL SC2SCLK SC2SCLK PA3 SC2nSSEL TIM2C2 TIM2C2 PA4 ADC4 PTI_EN TRACEDATA2 PA5 ADC5 PTI_DATA nBOOTMODE TRACEDATA3 PD4 SC3nRTS SC3nSSEL GND PE0 SC4MOSI SC4MOSI PE1 SC4SDA SC4MISO SC4MISO PA6 TIM1C3 TIM1C3 PB1 SC1MISO SC1MOSI SC1SDA SC1TXD TIM2C1 TIM2C1 PB2 SC1MISO SC1MOSI I/O O I I/O I O I I/O Analog O O I/O Analog O I O I/O O I Power I/O O I
Product Manual RF Module PIN 26 27 28 29 30 31 32 33 34 35 36 37 38 39 SIGNAL SC1SCL SC1RXD TIM2C2 TIM2C2 GND SWCLK JTCK PC2 JTDO DIRECTION I/O I O I Power I/O I I/O O SWO O TRACEDATA0 PC3 JTDI TRACECLK PC4 JTMS SWDIO PB5 ADC0 TIM2CLK TIM1MSK PC1 ADC3 TRACEDATA3 GND PC0 JRST IRQD TRACEDATA1 PB7 ADC2 IRQC TIM1C2 TIM1C2 PE2 SC4SCL SC4SCLK SC4SCLK PE3 SC4nSSEL PB6 ADC1 IRQB TIM1C1 TIM1C1 3.
Product Manual RF Module 3 CONFIGURATION INFORMATION A. Absolute Maximum Ratings of RF Module The following table provides maximum ratings of RF Module: Sr. No.
Product Manual RF Module Input pull-up resistor value RIPU 24 29 34 kΩ Input pull-down resistor value RIPD 24 29 34 kΩ Output voltage for logic 0 VOL (IOL = 4 mA for standard pads, 8 mA for high current pads) VOH (IOH = 4 mA for standard pads, 8 mA for high current pads) IOHS 0 0.18 x VDD_PADS V 0.
Product Manual RF Module D.Power Settings for Regulatory Compliance Because of the high gain of the frontend module output power of up to 24 DBM can be achieved When the antenna gain is included then the output power of the EM3597 transceivers needs to be reduced for regulatory compliance. The following tables list the maximum permitted power setting for the different antenna types listed. This is the power out of the EM3597 chip, and the power delivered to the antenna will be higher by the gain of the PA.
Product Manual RF Module 4 BOARD LAYOUT CIMCON RF modules do not have any specific sensitivity to nearby processors, crystals or other PCB components. Other than mechanical considerations, no special PCB placement is required for integrating CIMCON RF radios. In general, Power and GND traces should be thicker than signal traces and be able to comfortably support the maximum currents.
Product Manual RF Module 5 SOLDERING TEMPERATURE PROFILE a. Leaded Process b.Lead Free Process This information is confidential and proprietary to CLI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CLI is not permitted.
Product Manual RF Module 6 MECHANICAL DIMENSIONS OF THE SMT MODULES a. Dimensions This information is confidential and proprietary to CLI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CLI is not permitted.
Product Manual RF Module b. FOOTPRINT of the Module This information is confidential and proprietary to CLI and is to be used only for the purpose for which it is provided. Reproduction by any means, electronic or mechanical, and distribution to third parties without express written permission from CLI is not permitted.