GSM Alarm System Printed in Hong Kong PA: OI-G5/EN-Oct.2012-V1.
FCC Statement GSM Alarm System
Features Control Panel Layout ARM + Auror CPU GSM Signal Indicator Support 10 remote controls, 50 wireless sensors GSM network searching: Flashes once every second and 50 RFID tags GSM signal in normal: Flashes once every two seconds RFID Reader / Play Voice Memo Built-in 1,000,000 RF codes combination maintains high reliability Status Indicator Touch Keypad Cellular communicator, simple operation Store 5 phone numbers, 1 speed-dial number, and 1 RFID SMS notification number Exit and entry delay S
Bottom Back-up Batteries Arm Press to arm the system. Home mode Press to arm the sytem in home mode. All the sensors in Normal Zone are armed except those in Home Mode Zone which are disarmed so that user can move freely at home. Disarm on keypad: Input 4 digits password (default:1234) , and press the system after one beep. If three beeps are heard, password is wrong and please input again.
Bottom Record / Play Voice Memo Press to record 10 seconds voice messages. Or send SMS to system for calling back to record the SIM Card Slot voice messages. The Play Voice Memo Button will be flashing in purple to remind you. Users can touch the center of circle to listen to the voice memo. The LED indicator blacks out when the voice memo is played. Input for Wired Sensors (24-hour zone) Input for Wired Sensors (normal zone) Output for Electronic Lock Replay by touching it again.
SMS Operation Speed Dial Press Call Button , the panel auto dials to pre-stored Insert a SIM card to the control panel, phone number of the host, the LED blacks out after talk. then send a text of “?” to the SIM card number, User can also press Call Button the operation guide message will be replied. to end talk. You can control the alarm system by following the guide message: Send: Phone Call Dial phone number and then press Call Button to ? start talk, the LED blacks out after talk.
Send: ?? System replies second grade guide menu: ‘5’ Store alarm phone No. ‘6’ Store alarm SMS No. ‘7’ Store SMS No. for RFID tags ‘8’ Store speed dial phone No. ‘???’ System setups Disarm Send: 0 System disarmed.
Arm Two-Way Talk Send: Send: 1 3 System armed. Send ‘3’ to the SIM card number, the alarm will call back. Pick up the phone and start two-way talk. Stay Arm (Home Mode) Call-Back to Record Voice Memo Send: Send: 2 4 Send ‘4’ to the SIM card number, the alarm will call back. System in home mode. Pick up the phone, and leave 10 seconds message. The panel will hang up after 10 seconds.
Settings Inquiry Store Alarm Phone No. Send: Send: 00 System status Entry and exit delay time: 0sec Single zone delay time: 30sec Siren volume: 2 Siren ringing time: 5min Disarm password: 1234 5 TEL: 1. 2. 3. 4. 5. Note: Value of default setting will be changed once users finish programming. Forward > Edit TEL: 1. 67890033 2. 67890022 3. 67890011 4. 67890000 5. Store alarm phone No. successfully.
Store Alarm SMS No. Store SMS No. for RFID tags Send: Send: 6 7 SMS: 1. 2. 3. 4. 5. SMS No. for RFID tags (0-20 digits): 1. Forward > Edit Forward > Edit Store alarm SMS No. successfully. 15 SMS: 1. 67890033 2. 67890022 3. 67890011 4. 67890000 5. Note: Only after SMS No. is stored, and the RFID tags SMS notice is changed, users can receive notice SMS once someone disarms the system by RFID tag. SMS No. for RFID tags (0-20 digits): 1. 67890033 Store SMS No. for RFID tags successfully.
Store Speed Dial Phone Number Change Zone Name Send: Special Tips! Users can change the 1st~ 9 th zone names. The zone name should be 30 8 English characters at most for each line due to SMS character limit. Other alarm zones are fixed as Zone 10 alarm, Zone 11 alarm and so on. Send: 91~99 Speed dial phone number (0-20 digits): 1. 91 Zone1 name: Zone 1 alarm Forward > Edit Speed dial phone number (0-20 digits): 1.
SMS Alert for Low Battery of Accessories (available for two-way accessories such as DWC-102 and PIR-900/910) SMS will be sent for 1-9 zones with its zone name as “Zone name + low battery”. Bedroom PIR low battery. Change RFID Tags SMS Notice Send: 10 SMS alert for 10~50 zones will be “Zone number + low battery”. Zone 10 low battery. SMS Alert for Tamper Alarm of Accessories Change RFID tags SMS notice: 1. 2. 3. 4.
Entry and Exit Delay Time Siren Volume and Ringing Time Send: Send: 11 12 Entry and exit delay time (0-300 sec.): 0 Forward > Edit Siren volume(0 Mute, 1 Low, 2 High): 2 Siren ringing time(1-9min): 5 Entry and exit delay time (0-300 sec.): 10 Forward > Edit Set delay time successfully. Notice! If users don’t want to take remote control or RFID cards with them, this function can be used.
Disarm Password Single Zone Delay Time Send: Send: 13 14 Disarm password(4-6 digits): 1234 Single zone delay time (0-300 sec.): 30 Forward > Edit Set disarm password successfully. 23 Disarm password(4-6 digits): 8888 Forward > Edit Single zone delay time (0-300 sec.): 15 Set single zone delay time successfully.
Change System Language Delete Wireless Accessories by SMS Send: 0086 to change language to be Chinese Send: 21 0086 Delete wireless accessories successfully. 中文语言修改成功! Or press Tamper Switch 3 times within 3 seconds, accessories will be cleared after two beeps. Send: 0001 to change language to be English Delete RFID Tags by SMS 0001 Send: 22 Set English successfully. Delete RFID tags successfully.
Restore System to Default Setting by SMS Arm & Disarm by Free Phone Call Send: Arm Call the control panel number, hang up when hearing 0000 the ring tone. The panel will call back. The user hangs up the phone directly to arm the system. System has been restored to factory settings. Disarm Call the control panel number, hold on until the panel hangs up the call.The panel will not call back.
Connect Wireless Siren Specifications The newly-added wireless siren can be used after Product name : connecting to the control panel. GSM Alarm System Model No. : Operation: CG-G5 Press the Connect Button of the wireless siren for 0.5 second, Control panel’s power supply : the Connect Button LED indicator lights on, and then press Input: AC 110-240V/50-60Hz the Arm Button on the control panel, the siren will be Output: DC 12V/500mA connected after one beep is heard.
Radio frequency 315.