User Manual

1
Mini Door/Window Contact Detector (HSM01)
Installation and Operating Instructions
These instructions should be read in conjunction
with your System Installation and Operating
Manual and be retained for future reference.
The Door/Window contact detector is compatible with a
series of Everspring control panels – SC801, SC811,
SC821, or IP Gateway HSC04….,operating at 868
MHz or 923 MHz only.
The Door/Window contact detector consists of two
parts; a Detector and a Magnet. They are designed to
be fitted to doors or windows with the Magnet mounted
on the opening part and the Detector mounted on the
fixed frame. Opening the protected door/window will
remove the magnetic field, trigger the Detector and
generate an alarm condition, (if the system is armed).
The Detector is powered by 1 pieces of 3V CR2450
battery which under normal conditions will have typical
life in excess of 3 years. Under normal battery
conditions with tamper switch being pressed, the LED
on the Detector will not illuminate when the Detector is
triggered. However, under low battery conditions this
LED will be illuminated when the detector is triggered.
When this occurs the battery should be replaced as
soon as possible.
CHOOSING A MOUNTING LOCATION
The Door/Window Contact is suitable for mounting in
dry interior locations only.
Decide which doors/windows are to be protected by
Door/Window Contact, (usually the front and back
doors as a minimum will have Door/Window Contact
fitted). Additional detectors may also be fitted where
required to other vulnerable doors or windows, (e.g.
garage, patio/conservatory doors etc).
Note: Take care when fixing the Detector to a metal
frame, or mounting within 1m of metalwork (i.e.
radiators, water pipes, etc) as this could affect the radio
range of the device. If required, it may be necessary
to space the magnet and detector away from the metal
surface using a plastic or wooden spacer to achieve
the necessary radio range.
INSTALLING THE DOOR/WINDOW
CONTACTS
Ensure that the system properly powered.
Factory default built in a CR2450 battery inside the
detector and uses a Mylar film to isolate battery from
electric circuit of the detector. Remove the battery
Mylar film when ready to let the detector work.
If there is no battery inside the detector or need to
replace a new battery please insert the battery in 45°
angle as below figure
FIX AND TEST THE DOOR/WINDOW CONTACTS
1. Using the adhesive tape to fit detector on the door
or window.
2. Fit the Magnet to the moving part of the
door/window opposite the Detector using the
adhesive tape.
3. Ensure that the parallel gap between the Magnet
and Detector is less than 20mm and that the
matching line on the Magnet is pointing towards
and aligned with the line on the Detector. An alarm