User's Manual

1
HAN02 IN-WALL SWITCH MODULE
This in-wall switch module is a transceiver which is a Z-Wave
TM
enabled device and
is fully compatible with any Z-Wave
TM
enabled network. Z-Wave
TM
enabled devices
displaying the Z-Wave
TM
logo can also be used with it regardless of the manufacturer,
and ours can also be used in other manufacturer’s Z-Wave
TM
enabled networks.
Remote On/Off control of the connected load is possible with other manufacturers
Wireless Controller.
This in-wall switch module is able to detect overload wattage of connected
non-dimmable lights or appliances. When detecting overload state, the module will be
disabled and its On/Off button will be lockout of which LED will flash quickly.
However, disconnect and re-connect the wiring of the module will reset its overload
condition to normal status.
Adding to Z-Wave
TM
Network
In the front casing, there is an On/Off button with LED indicator which is used to carry
out inclusion, exclusion, reset or association. Toggle On/Off button between On and
Off. When first power is applied, its LED flashes on and off alternately at 2-second
intervals. It implies that it has not been assigned a node ID and cannot work with
Z-Wave enabled devices. Put a Z-Wave
TM
Controller into
inclusion/exclusion/association mode, the module executes the function of auto
inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the module does not have
node ID when the first power is applied.
After node ID has been linked, auto inclusion will run automatically after the
execution of exclusion/reset is successful.
Note: Auto inclusion lasts for 4 minute or until the execution of inclusion is completed
during which the node information of explorer frame will be emitted once every 5
seconds. Unlike “inclusion” function as shown in the table below, the execution of
auto inclusion is free from pressing the On/Off button on the module.
Function Description LED Indication
No node ID After power is applied, if the module
does not record a node ID provided by
controller.
2-second on, 2-second off
1. Have Z-Wave Controller entered
inclusion mode.
Inclusion
2. Pressing On/Off button three times
within 1.5 seconds will enter
inclusion mode or
3. Close and open manual switch input
of S1 or S2 between C three times
within 1.5 seconds at the first 3
minute when the first power is
applied will enter inclusion mode
1. Have Z-Wave Controller entered
exclusion mode.
2. Pressing On/Off button three times
within 1.5 seconds will enter
exclusion mode or
3. close and open manual switch input
of S1 or S2 between C three times
within 1.5 seconds at the first 3
minute when the first power is
applied will enter exclusion mode
Exclusion
Node ID has been excluded
successfully.
2-second on, 2-second off
On/Off Button
LED Indicator
manual switch input

Summary of content (4 pages)