User`s manual

RPMS-D100U/UF,
CS50-D100U, CS70-D100U/UF
54-003766-01P (10/04) 1 of 6
Lamp Replacement
- Instruction Sheet -
Introduction
Applies to RPMS-D100U/UF (38-GFX204-01, 38-GFX205-01, 38-GFX206-01, 38-GFX207-01),
CS70-D100U/UF (38-GFX052-xx, 38-GFX053-xx) and CS50-D100U (38-GFX054-xx).
RPMS-D100U/UF, CS50-D100U and CS70-D100U/UF units use two identical 100W UHP
(Ultra High Pressure) lamps and can be operated with both lamps ON (Dual Lamp Operation
mode) or with one lamp ON (Single Lamp Operation mode). The projector will automatically
switch modes to maintain continuous operation. Use the following information and
instructions when replacing the lamps in these projectors.
NOTE: Refer to the User’s Manual (54-017188-xxP) for more information on Lamp Operation
Modes.
Components Required
Lamp Replacement Kit #03-240088-xxP (kit includes 100W UHP lamp, instructions, lamp warranty claim form,
RMA form, service safety sheet)
Phillips #1 screwdriver
Safety and Warning Guidelines
Please read before proceeding with lamp replacement
Read the Lamp Replacement procedure in its entirety before proceeding.
Never stick hands into an empty lamp compartment while the projector is still
plugged into an AC outlet.
Use caution when handling lamps. Lamps, even those that have been through a
cool down period, are still hot due to the heat emitted from the other operational lamp.
Do not touch the glass surface of the lamp. Grip the lamp by the handle only.
Fingerprints left on the glass surface of a lamp can lead to an intense accumulation of
heat called “hotspots” that could potentially cause the lamp to explode. Wear clean,
lint-free cotton gloves when handling the lamp to prevent fingerprints.
Instructions
When should lamps be replaced?
Typically, aging lamps decrease slightly in their intensity. You can check the number of hours
each lamp has been in use by checking Lamp Hours in individual lamp submenus. From the
Lamp menu, you can also set a Lamp Limit (max 20,000 hours) and enable the projector to
send a lamp replacement, warning message when it’s powered on.
At anytime during operation, you can check the status of a lamp by checking the Lamp Strike
Status in individual lamp submenus — More, Lamp 1 or More, Lamp 2. You will see one of six
states: “Good”, “Cooling Fan #3 Failed”, “Cooling Fan #5 Failed, “Interlock Tripped”, “Failed
to Strike” and “Turned Off Unexpectedly”. A status of “failed to strike” or “turned off
unexpectedly” indicates a failure that requires further investigation and may or may not be
directly related to the lamp.