PAB SAB Sounder Sounder Metal PAB Point Lights Sync Out Sync In TX2 TX1 Badge Board Input Power SAB Lights Alarm Relay Optional 3rd TX Interface Figure 6X*** TR4215 Reader Board Figure X*** shows the specific connectors for the peripherals. ** J numbers for the connectors. NGL FX Installation Manual Rev.
Transmission Line / A1111 Wiring The A1111interface board connects to each FX antenna via the 15m (50 ft) transmission line. Apply the ferrite cores as show and tighten the clamp. Figure X** displays the interface board and connections. Before connecting to the A1111 board, slide the ferrite core (P?N) over the transmission cable. NGL FX Installation Manual Rev.
Connect the leads according to the diagram below and tighten clamps that hold the wires to the chassis. ***Update Graphic. BLUE/WHITE DRAIN ORANGE/ WHITE WHITE/ ORANGE DRAIN Figure 16: A1111 Wire terminal Connections WHITE/BLUE At Connector Port J1 (TX2): NGL FX Installation Manual Rev.
• Connect one drain wire from the 15.2m (50-ft) transmission line to the center terminal • Connect the ORANGE/WHITE lead to the terminal left of this drain wire • Connect the WHITE/ORANGE lead to the terminal right of this drain wire At Connector Port J2 (TX1): • Connect the second drain wire from the 15.2m (50-ft) transmission line to the center terminal • Connect the BLUE/WHITE lead to the terminal left of this drain wire • Connect the WHITE/BLUE lead to the terminal right of this drain wire .
Remote voice alarm or alarm post Connect the peripheral Lights and Sounder wiring as indicated below. Remote voice alarm or alarm post. White wire connects to the voice alarm.
Wiring Between FX Systems for Sync Where multiple floor systems are installed, it may be necessary to install sync wire and network communication cable between the aisles. Sync Cable The sync cable (RF Sync) should be installed between FX systems if the distance between aisles is under 40 feet. If two aisles are more than 40 feet apart, no sync cable is needed. Use 22 AWG 4-conductor (STP) (5594) cable for sync cable. Follow the Sync Cable Wiring Table below to wire it to appropriate terminals.
Wiring 24VDC power supply A Checkpoint-certified 24VDC power supply can power up to two (2) FX systems. The cable is plenum rated (MC Armored cable) with AWG18 two (2) conductor cable + ground. Wire the plenum cable to the DC filter board input according to the Pinout below. Connect the wires from this PAB’s filter board to J18 connector on the reader. The other output from the filter board could be wired to other PAB filter board input. *** fix wiring instruction.
Figure 12 24 VDC power filter Synchronizing, Slaving and System Proximity Systems operating together as a unit, as opposed to individual floor systems***, have to be synchronized or “synced” together using an approved sync cable for the system (i.e., Belden # 8723, Consolidated # 5594, etc.). At minimum there should be a 2 wire and shield. This minimum wire will not give an alarm group function. For alarm grouping, a 2 pair with shield cable must be used.
CHAPTER 5 NETWORKING AND PERIPHERALS Overview This chapter describes the PX/QX with Coupler antennas peripheral device wiring. Note: peripheral device wires go to primary antenna only. Peripherals Both PX and QX with Coupler systems support following peripheral devices: Voice Alarm Metal Detection Please refer the peripheral device’s installation manuals for proper installation and wiring NGL FX Installation Manual Rev.
CHAPTER 6 N G L S Y S TE M C O N F IG U R A T IO N V I A D M S Overview This chapter reviews the DMS configuration steps for the FX system using DMS. Antenna tuning including coupler jumper setting is covered in Chapter 7: NGL Tuning. Please follow this tuning guide to optimize the system performance after completing the system configuration. Note: Please use DMS version 1.8.31 and later. TR4215 firmware version must be 4.00 and later.