Counterpoint iD Quick Start Guide Reference During Installation CKP P/N 10073883
CPiD - Quick Start Guide Copyright © 2014 by Checkpoint Systems, Inc. All rights reserved. Checkpoint® is a registered trademark of Checkpoint Systems, Inc. Released March 21, 2014. Published by: Checkpoint Systems Inc. 101 Wolf Drive Thorofare, NJ 08086 For use with Checkpoint’s Counterpoint Intelligent Deactivation System. Checkpoint, Counterpoint, Evolve, VisiPlus and People Counter are registered trademarks of Checkpoint Systems, Inc. All rights reserved.
Quick Start Guide: Counterpoint iD Installation Requirements What’s In The Box 1 CPiD Chassis 1 Power Supply Unit (PSU) Install kit including: 2 #8 hex head screws (5/8 inch long) 2 tie wraps 1 6-Pin connector Tools Required 1 small flathead screwdriver 1 1/4 inch nut driver Optional DMS Version 1.8.95 or later (required for setup of advanced features) Operation/Features Front 1 Sounder Sounder for alarm annunciation 2 Status LED Informs the User about device status.
Checkpoint Systems, Inc. – Field Service Installation Document – CKP P/N 10073883 Rear 1 Input Power Connector Connector for +12V DC input power 2 DC Jack Strain Relief Strain relief for power cord 3 Internal Cabling exit Opening for all cables that connect internally (e.g., Antenna Cable) 4 USB Connector Connector for future USB functionality Inside This is what you find, pre-install with chassis cover (plate) removed. 1 Antenna 1 and 2 Primary RF Connection for 2 antennas max.
Quick Start Guide: Counterpoint iD 3 Alarm and Interlock Connection for Interlock and Alarm Interlock Description / Pin-out Interlocks are external devices that relay control signals to the device 1 Interlock Input. Default is shorted to Pin 2 using wire jumper 2 GND 3 Interlock Opto, polarity independent (jumper must be removed prior to use).
Checkpoint Systems, Inc. – Field Service Installation Document – CKP P/N 10073883 Status LED Functions Status LED Function Red Detection (Tag Alarm) X Yellow Waiting for Interlock X Keyswitch disabled X AutoTune Blink Blue Teal White Auto Tune Window Violet Green 0.
Quick Start Guide: Counterpoint iD Mounting A secure location, such as behind an access door below the register, is ideal for mounting. Plan routing and location so the unit will not be struck by anything. When possible, locate unit such that user has ability to interface with device. Consult the SOW when provided. Customer may prefer / request no access. Volume can only be muted in DMS. Choose 1 of the following orientations: Figure 1: Typical Orientations Top plate has front and rear.
Checkpoint Systems, Inc. – Field Service Installation Document – CKP P/N 10073883 Wiring Procedure 1. Connect antenna cable(s) according to Table on page 2. Plug into ANT1 ANT2 connector, then route cable(s) through the clips for strain relief. Dog-bone excess antenna cable with provided tie wrap. Figure 2: Antenna Wiring, Primary Connection (Cable Routing on right) 2.
Quick Start Guide: Counterpoint iD Figure 4: PSU DC Cord Strain Relief 4. Configure the DIP Switches on the front panel for the desired operation. Note: For details on “Mode Configurations”, see DIP Switch Functions on page 3 above. 5. System is ready to power ON. With no advanced features required, the final step is to press Reset button, wait for the Violet LED, then press reset again to tune. 6.
Appendix A: Regulatory and Safety Important Information to our Users in North America FCC Regulatory Compliance Statement Checkpoint Systems, Inc., offers Electronic Article Surveillance (EAS) or Radio Frequency Identification Products that have been FCC certified or verified to 47 CFR Part 15 Subparts B/C.
Antenna Type Antenna Structure Antenna Size Conveyor Deactivation Pad 1 turn loop 9.8” x 9.8” Handheld deactivator 1 turn loop 10” x 8” Hand scan antenna 1 turn loop 6.8” x 1.5” Sheet deactivator 1 turn loop 9.4” x 9.
Appendix A: Regulatory and Safety Important Information to our Users in Europe CE Regulatory Compliance Statement Where applicable, Checkpoint Systems, Inc. offers certain Electronic Article Surveillance (EAS) products that have CE Declarations of Conformity according to R&TTE Directive 99/5/EC, EMC Directive 2004/108/EC, and Low Voltage Directive 2006/95/EC.
WEEE Marking All products that are subject to the WEEE Directive supplied by Checkpoint are compliant with the WEEE marking requirements. Such products are marked with the "crossed out wheelie bin" WEEE symbol shown below in accordance with European Standard EN 50419. Information for Users According to the requirements of European Union member state WEEE legislation, the following user information is provided in English for all Checkpoint supplied products subject to the WEEE directive.