User Manual
TABLE OF CONTENTS 1. Before You Begin .......................................................................................................... 3 What is Included ............................................................................................................................... 3 Unpacking Instructions ..................................................................................................................... 3 Claims ....................................................................
1. BEFORE YOU BEGIN What is Included • • • Geyser™ RGB Jr. Geyser™ Wireless Remote Control Geyser™ Wired Remote Receiver • • • Power Cord Warranty Card Quick Reference Guide Unpacking Instructions Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.
Safety Notes These notes include important information about the mounting, usage, and maintenance of this product; read before using the product. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Page 4 of 16 Always connect the product to a grounded circuit to avoid the risk of electrocution. Always disconnect the product from the power source before cleaning or replacing the fuse. Avoid direct eye exposure to the light source while the product is on.
2. INTRODUCTION Overview Fluid Tank Manual Fog Button Nozzle and LEDs On/Off Switch Handles LED Display Remote Control Receiver Port Control Buttons Safety Eye Loop Geyser™ RGB Jr. User Manual Rev.
Dimensions 16.04 in (407.5 mm) 10.39 in (264 mm) 2.39 in (60.8 mm) 7.55 in (191.9 mm) Page 6 of 16 Geyser™ RGB Jr. User Manual Rev.
3. SETUP AC Power The Geyser™ RGB Jr. has a fixed voltage power supply and it can work with an input voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the specific model. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Mounting Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. Orientation Primarily, the Geyser™ RGB Jr. is to be floor mounted in a vertical fog jet orientation. Alternatively, it may also be mounted in a floor mounting/horizontal fog jet orientation or in an overhead mounting/downward fog jet orientation; however, be sure to follow instructions closely to avoid tank spills with alternate mountings. When mounting the Geyser™ RGB Jr.
TRUSST® (or other elevated platform or truss) Mounting Clamps for the Geyser™ RGB Jr. (works with CLP-15 or CLP-15N clamp from Chauvet) Safety Cable for the Fluid Tank Alternate Inverted Truss Mounting The Fluid Tank in an upright position Safety Cable Overhead Mounting – Downward Fog Jet With inverted mounting, avoid spillage of the fog fluid by setting the fluid tank in an upright position. Be sure to use a safety cable for both the Geyser™ RGB Jr. and the fluid tank when rigging in this manner.
Tank Inversion for Inverted Mounting 1. Remove the screws and the bottle lock to take out the tank. Bottle Lock 2. Turn the fog machine upside down and remove the screws to take off the removable plate. Removable Plate 3. Page 10 of 16 Attach the removable plate to the opposite side and secure the tank with the bottle lock. Geyser™ RGB Jr. User Manual Rev.
4. OPERATION Control Panel Operation To access the control panel functions, use the four buttons located underneath the display.
Configuration (Standalone) Wireless Remote Control Set the product without a DMX controller. 1. Connect the product to a suitable power outlet. 2. Turn the product on. To trigger fog output and activate the color program using the wireless remote control, do the following: 1. Plug the wireless receiver into the Remote Control Receiver port on the side of the Geyser™ RGB Jr. 2. On the wireless transmitter, press the button assigned to the color program (1–4). The Geyser™ RGB Jr.
5. TECHNICAL INFORMATION Fogger Maintenance Do not allow the fogger to become clogged. After every 40 hours of continuous operation, use CHAUVET® Fog Cleaner Quart (FCQ) through the system to prevent the accumulation of particulate matter in the heating element. The recommended cleaning procedure is as follows. 1. Unplug the product from power. 2. Empty all fog fluid from the machine. 3. Add cleaning solution to the tank. 4. Plug in the product and allow it to warm up. 5.
General Troubleshooting Symptom No output or low output or fog machine is spitting fluid Circuit breaker or fuse keeps blowing Product does not power up Product does not output fog Display Possible Cause Wrong fluid Clean thoroughly with CHAUVET® FCQ. For full instructions, see Fogger Maintenance. Refill with CHAUVET® water-based fog fluid.
6. TECHNICAL SPECIFICATIONS Dimensions and Weight Length Width Height Weight 16.04 in (407.5 mm) 10.39 in (264 mm) 7.55 in (191.9 mm) 16 lb (7.3 kg) Note: Dimensions in inches rounded to the nearest decimal digit. Power Power Supply Type Range Voltage Selection Model-specific 120 VAC, 60 Hz or 230 VAC, 50 Hz Fixed Parameter 120 V, 60 Hz 230 V, 50 Hz Consumption 670 W 690 W Operating current 5.
To return a product or request support: • • • • In the U.S., contact Chauvet World Headquarters. In the UK or Ireland, contact Chauvet Europe Ltd. In Mexico, contact Chauvet Mexico. In any other country, DO NOT contact Chauvet. Contact your distributor. See www.chauvetlighting.com for distributors outside the U.S., United Kingdom, or Ireland. If you live outside the U.S., United Kingdom, or Ireland, contact your distributor of record and follow their instructions on how to return Chauvet products to them.