User Manual
TABLE OF CONTENTS 1. Before You Begin ...........................................................................................................3 What Is Included ......................................................................................................................... 3 Unpacking Instructions ................................................................................................................ 3 Claims ...............................................................................
1. BEFORE YOU BEGIN What Is Included • • • EZpar™ 64 RGBA Infrared Remote Control (IRC) Power Cord • • Warranty Card Quick Reference Guide Unpacking Instructions Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition. Claims If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not CHAUVET®.
Product at a Glance Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave Safety Notes Auto Programs Auto-ranging Power Supply Replaceable Fuse User-Serviceable P P P x These notes include important information about the mounting, usage, and maintenance of this product; read before using the product. • • • • • • • • • • • • • • • • • • • • Page 4 of 20 x x P P P Always connect the product to a grounded circuit to avoid the risk of electrocution.
2.
Dimensions 10.8 in 276 mm 10.8 in 275 mm Page 6 of 20 2.
3. SETUP AC Power The EZpar™ 64 RGBA has an auto-ranging power supply and it can work with an input voltage range of 100~240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Fuse Replacement Disconnect the product from power before replacing the fuse. 1. 2. 3. 4. 5. 6. Disconnect the product from power. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder. Pry the fuse holder out of the housing. Remove the blown fuse from the holder. Replace with a fuse of the exact same type and rating. Insert the fuse holder back in place and reconnect power.
Power Linking The product provides power linking via the Edison/IEC outlet located in the back of the unit. st 1 Product Power Linking Diagram 2nd Product rd 3 Product Additional Products You can power link up to 55 EZpar™ 64 RGBA units on 120 VAC or up to 85 EZpar™ 64 RGBA units on 230 VAC.
Mounting Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. Orientation The EZpar™ 64 RGBA may be mounted in any position; however, make sure adequate ventilation is provided around the product. Rigging • Before deciding on a location, always make sure there is easy access to the product for maintenance and programming.
4. OPERATION Control Panel Operation To access the control panel functions, use the four buttons located underneath the display.
Configuration (DMX) Starting Address Page 12 of 20 Set 1. 2. 3. the product in DMX mode to control with a DMX controller. Connect the product to a suitable power outlet. Turn the product on. Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product. When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses.
DMX Channel Modes, Assignments, and Values 8-Channel Channel Value Setting Red Green Blue Amber Color Macros (Overrides Channels 1–4) 000 ó 000 ó 000 ó 000 ó 000 ó 016 ó Speed (When Channel 7 is 032–223) 000 ó 255 Slow to fast Strobe 000 ó 015 No function 016 ó 255 Slow to fast 7 Mode 000 ó 032 ó 064 ó 096 ó 128 ó 160 ó 192 ó 224 ó 8 Dimmer 000 ó 255 0–100% 1 2 3 4 5 6 4-Channel Function Channel Function Value 255 255 255 255 015 255 031 063 095 127 159 191 223 255 0–100% 0–100% 0–1
Configuration (Standalone) Set the product in one of the standalone modes to control without a DMX controller. 1. Connect the product to a suitable power outlet. 2. Turn the product on. Never connect a product that is operating in any standalone mode (Static, Automatic, or Sound-Active) to a DMX string connected to a DMX controller. Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller.
Static Colors To select a preset static color, do the following: 1. Press
IRC Operation Note: Make sure to point the IRC directly at the receiver on the front of the product. Automatic Mode Automatic mode will enable you to run the automatic programs on the product. To turn on Automatic mode: 1. Press on the IRC. 2. Press <+> or <–> to choose between any different auto programs. To adjust the speed of the automatic program: 1. Press on the IRC. 2. Press <%>. 3. Press <+> or <–> to either increase or decrease the speed of the program.
Master/Slave Mode The Master/Slave mode allows a single EZpar™ 64 RGBA unit (the “master”) to control the actions of one or more EZpar™ 64 RGBA units (the “slaves”) without the need of a DMX controller. The master unit will be set to operate in either an automatic program or Sound-Active mode, while the slave units will be set to operate at DMX address d 1. Once set and connected, the slave units will operate in unison with the master unit. Configure the units as indicated below. Slave units: 1.
5. TECHNICAL INFORMATION Product Maintenance Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and mechanical wear. To maintain optimum performance and minimize wear, clean the product at least twice a month. However, usage and environmental conditions contribute to increased cleaning frequency. To clean the product, follow the instructions below: • Unplug the product from power.
6. TECHNICAL SPECIFICATIONS Dimensions and Weight Length Width Height Weight 10.8 in (276 mm) 10.8 in (275 mm) 2.6 in (66 mm) 4 lbs (1.9 kg) Note: Dimensions in inches rounded to the nearest decimal digit. Power Light Source Photo Optic Battery Thermal DMX Ordering EZpar™ 64 RGBA User Manual Power Supply Type Range Voltage Selection Switching (internal) 100~240 V, 50/60 Hz Auto-ranging Parameter 120 V, 60 Hz 230 V, 50 Hz Consumption 33 W 35 W Operating 0.3 A 0.
To return a product or request support: • • • In the U.S., contact CHAUVET® World Headquarters (see below). In the UK or Ireland, contact CHAUVET® Europe Ltd. (see below). In any other country, DO NOT contact CHAUVET®. Contact your distributor. See www.chauvetlighting.com for distributors outside the U.S., United Kingdom, or Ireland. If you live outside the U.S., United Kingdom, or Ireland, contact your distributor of record and follow their instructions on how to return CHAUVET® products to them.