Wearable Blood Pressure Monitor E X C E L L E N C E I N H E A L T H C A R E
Wearable Blood Pressure Monitor
www.charmcare.
www.charmcare.
www.charmcare.com Thank you for purchasing the H2-BP(model name of Automated Electronic Sphygmomanometer made by Charmcare Co., Ltd. ("Charmcare")} ). For the safe operation of this product, it is recommended that you read this user manual thoroughly before using. Purpose This sphygmomanometer is a "Medical Device" suitable for IEC80601-2-30 and is an electronic device that measures blood pressure indirectly (non-invasive).
www.charmcare.com Contact Us Contact us at the following numbers and addresses to receive various services and products. Need to purchase products or parts? Need service or repairs? Website Rm714, 2, Gasandigital1-ro, Geumcheon-gu, Seoul, 08591, Korea Tel: +82-70-4756-8355 Fax: +82-2-862-5065 http://www.charmcare.com E-mail: cs@charmcare.com Definition of Terms ● The user must follow all warnings and precautions.
www.charmcare.com Proper Environments for this Product Do not use or store this product in the following conditions: Do not expose this product to humidity and/or moisture or areas where air circulation is a problem. Do not store or place this product in direct sunlight. Use this product between temperatures of 10 ℃ and 40 ℃, and at a humidity between 0% and 95%. Do not place this product near heat sources. Do not store or place this product in places where it is exposed to chemicals or flammable gas.
www.charmcare.com Safety Precautions Do not shock or drop this product. ● Do not measure without wearing this product on your wrist. ● Dispose of body, parts and accessories of this product according to local regulations. ● For specific information about your own blood pressure, consult with your physician. ● Contraindication ● ● This product is contraindicated for use in ambulatory environments. This product is contraindicated for use on aircraft.
www.charmcare.com · Please do not adjust dosage on your discretion according to the measurement results. · Please take your medicine according to your physician's prescription. · Diagnosis and treatment of hypertension is only possible with your physician. · Please consult with your physician before using, if you have any of the symptoms below.
www.charmcare.com · Please do not use in a location where there is moisture or a risk of splashing water over this product which may damage the product. · Please keep this product clean. If this product is causing skin irritation due to sweat or contamination, stop using it and consult with your dermatologist. · Please do not let chemical products such as lotions, oils, skin creams or cosmetics collect on the product.
www.charmcare.com · Please consult with your physician for specific information about your own blood pressure. · Self-diagnosis or self-treatment according to measurement results is dangerous. · Please consult with your physician if you have the symptoms following below. - In case of wire ablation - In cases of severe blood disorders or internal bleeding due to compression. · Please do not measure more often than necessary. Internal bleeding may occur due to compression.
www.charmcare.com · Use this product to measure your blood pressure regularly, record your results and consult with your physician. · When measuring blood pressure, the position of the cuff should be accurately set at the radial artery, and the cuff should be at the same level as your heart. · Blood pressure changes frequently during the day, and can be greatly affected by smoking, drinking, medication, and exercise, so please measure 30 minutes after exercise and 2 hours after meals.
www.charmcare.com Product Symbol Description The serial number that identifies the object.
www.charmcare.com Maintenance and Cleaning Wearable blood pressure monitor device can be kept clean using various methods. Avoid any damage or contamination of this product using the methods recommended below. ● This product is not covered under the guarantee period free of charge in cases of using unauthorized substances that can damage the product. · After cleaning this product, check it's monitor. · Do not use this product if it is beyond the expiration date or damaged.
www.charmcare.com Data Transmission ● This product emits radio frequencies (RF) in the 2.4 GHz band. Do not use this product in areas where RF is restricted, such as on an aircraft or in hospitals. Turn off the Bluetooth® feature of this product when in RF restricted areas . Calibration and Service The accuracy of this product has been carefully tested and is designed to last. ● To maintain proper operation and accuracy of this product, it is recommended that you inspect it regularly once a year.
www.charmcare.com Composition of Product Basic Unit Basic Accessories Type Description Charging Cable 5V USB connector Tape Measure A tool that measures the girth size of the wrist Adjusting Pin Pin to adjust height User Manual A guide for user Quick Start Guide Quick manual for user · Do not swallow accessories. This may result in choking. · Please purchase accessories via Charmcare or it's distributors.
www.charmcare.com Name of each part of wearable blood pressure monitor DESCRIPTION Display Switch 1 Switch 2 Cuff Height-adjusting Hole Band Strap Hook Band Strap Charging Terminal Charging Cable Adjusting Pin Tape Measure · For electrical safety, this product should not be disassembled.
www.charmcare.com This manual describes the basic names and functions of this product that users need to know, and provides information for simple use. Precautions when using ● Use this product within the ambient temperature of 10℃ - 40℃ and the humidity of 0% - 85%. ● Check the battery charge status. ● Be careful because this product is easily damaged by impact.
www.charmcare.com Preparation before wearing ● Tape Measure for measuring wrist circumference (1) Measurement | With the enclosed ‘Tape Measure’, measure the wrist circumference. And check the number and letter (alphabet) that fits the user. ● Adjusting Pin C A B (2) Adjustment | ① Height Adjustment: Insert the adjusting pin to be matched to the hole on the band and push or pull the band to adjust the height to the letter from A to C you measured.
www.charmcare.com ② Strap Adjustment: Tighten the band size to the number from 1 to 5 you measured. 6.7 inch~8.7 inch (17 cm ~ 22 cm) * Note: The H2-BP device fits adult wrists from 6.7 inch to 8.7 inch (17 cm to 22 cm) in circumference. ● * Before wearing the device, please make sure there is some gap between the wrist and the band. Be careful not to press the ulnar artery with the hard part of the band. You can normally wear the band loosely except when you measure your blood pressure.
www.charmcare.com How to wear ● The band is to be set to the palm as close as possible. Do not wear the band on the part of the lower arm. Please make sure the band neither to be too tight nor too loose to have some space, so a finger barely goes through it as shown.
www.charmcare.com Accurate measurement posture If the position of the wrist is different from the height of the heart, the blood pressure results change due to the weight of the blood itself. The results show that when the wrist position is higher than the heart, the blood pressure value is lowered and vice versa. A change of 8 mmHg per 4 inch occurs. However, since the blood pressure result is also affected by the measurement posture, it does not necessarily follow this exact result.
www.charmcare.com Power ● Press switch 1 for more than 2 seconds. Blood pressure measurement ① While wearing the product, press switch 1. ② As pressure is applied to the wrist, the current pressure is displayed on the screen.
www.charmcare.com ③ When the measurement is completed, the measured blood pressure result is displayed. Repeated measuring at intervals of about 10 minutes. · If the band strap is loose, blood pressure measurement may not be possible. · If the cuff is not positioned over the radial artery, a blood pressure measurement error may occur. · During the measurement, you should not speak or move.
www.charmcare.com Display clock ① Press switch 2. ② The current time is displayed. Display of stored blood pressure measurements ① Press switch 2 twice. ② The blood pressure measurement date, time and index values are displayed. ③ The blood pressure measurement result is displayed. · Every time you press switch 2, the displayed contents change. · After confirming the last blood pressure result, press switch 2 again to display the clock.
www.charmcare.
www.charmcare.com How to set up ② Selected menu:Press switch 2 to move to selected menu and press switch 1 to complete menu selection. ③ Settings change:Press switch 2 to change the selected setting, then press switch 1 to complete the setting change. · If no switches are pressed for 10 seconds, the setting menu is exited. · Press and hold switch 2 for 3 seconds to quickly change the setting. · Press switch 1 for 3 seconds to cancel the change and move to the upper menu.
www.charmcare.com Automatic clock display mode by operation ① Select the AUTO menu. ② When ON is selected, the screen auto-on by motion is activated. ③ When OFF is selected, the screen auto-off by motion is activated. If the screen auto-on is set, the battery may run out quickly.
www.charmcare.com Date and Time Setting ① Select from the TIME menu. ② Set the year. ③ Set the month, day ④ Set the hour, minute This function is a menu to set the date and time if you cannot synchronize with the app. When you synchronize with the app, the time is automatically set to the date and time on your mobile phone, so you do not need to set it manually.
www.charmcare.com Delete Data ① Select from the DEL menu. ② If you select YES, the data will be deleted. If you delete the data, it will not be possible to recover it, so please be careful before deleting data. Count ① Select the COUNT menu to see the number of measurements. Language ① Select the Language menu ② Select your language.
www.charmcare.com How to use the charger Lightly place the charging cable on the charging terminal as shown in the figure. Charging terminal Charging cable · Do not pull the charging cable. When handling the charging cable: - Do not damage it. - Do not break it. - Do not tamper with it. - Do not forcibly bend or pull it. - Do not twist it. - Do not use it if it is gathered in a bundle. - Do not place it under heavy objects. · Charging time is around 1 hour and 30 minutes.
www.charmcare.com Battery Status If it is less than 10%, blood pressure cannot be measured and only the clock and the stored blood pressure measurement results can be checked. Smartphone Application How to pair the H2-BP with the application. 1) Search for H2-BP in your app store and install. 2) Open the H2-BP application after turning Bluetooth on and register your H2-BP through the application. *Bluetooth connectivity is available for Bluetooth 4.0 version and above.
www.charmcare.com Do not move while taking the measurement. Poor cuff condition Wear the cuff correctly and refer to the instructions. Check the cuff is inflating properly by pressing the switch 1. Please contact Charmcare or it's distributor.
www.charmcare.com This page describes simple troubleshooting when problems occur during use. Sometimes it does not work as intended or you do not know what to do. Do not think of it as a 'failure' at this point and check the following. Quick Treatment Charge the battery. Charge the battery. Charge the battery. Keep wrist at heart level. Measure in a comfortable position. If you talk or move your arm during the measurement. Measure it quietly and do not move. In case of air leakage from the cuff.
www.charmcare.com 160 mAh 1 h 30 min 3 days; decreasing with the increase of measurements. 1 year Measurable Girth Size of Wrist 6.7 ~ 8.
www.charmcare.com Micro pump 10 ℃ ~ 40 ℃ 0% ~ 85% -20 ℃ ~ 70 ℃ 10% ~ 85% How to store and manage this product after use ① Do not store it near water. ② Do not store it under the influence of air pressure, temperature, humidity, wind or the like. ③ Be careful of the unstable state such as vibration and accidental impact including transportation. ④ Do not place it in an area used of chemicals-storing or gas-generating.
www.charmcare.com Classification of BP(Blood Pressure) Categories for BP in Adults* ~ ~ ~ * Individuals with Systolic BP and Diastolic BP in 2 categories should be classified into the higher BP category. BP stands for blood pressure. Blood Pressure should be measured on 2 or more occasions to be classified in a category.
www.charmcare.com There is approximately ±10 mmHg difference between the measured values of the wrist and upper arm blood pressure when you are in a good condition. However, the blood pressure of the upper arm and wrist value may vary significantly immediately after excersing or bathing. Diabetes, hyperlipidemia, hypertension and the like promote atherosclerosis especially as the symptoms progress.
www.charmcare.com In relation with meals generally there is no significant difference between the preprandial upper arm and wrist blood pressure as well as the postprandial one. However, in case of entering a bath with a high water temerpature, the blood pressure goes high due to the contraction of the blood vessels of the skin. On the other hand, when bathing slowly in lukewarm water, the peripheral blood vessels expand and the blood pressure goes down.
www.charmcare.com Differences in blood pressure according by posture There is a distinct blood pressure difference between lying down, sitting and standing. The blood pressure of the standing posture is about 5 mmHg higher than that of the lying down posture on diastole while the blood pressure of the lying down posture is 8 mmHg higher than that of the sitting posture. The blood pressure of legs-crossed is about 28 mmHg higher than that of the legs-spread posture.
www.charmcare.com Measured results at home vs. at the hospital In some cases, the results of the blood pressure measured at home may be to the maximum extent of 20 ~ 30 mmHg lower than those of the blood pressure measured at the hospital because you feel nervous there. So, knowing your blood pressure results measured at home is needed.
www.charmcare.com The measured results for each intraday measurement Are you always measuring under th same conditions? Nonstop measuring of the blood pressure in one day is likely to give you different results, therefore it must be done under the same conditions. Ensure you are in the correct guided posture. Frequent measuring of your blood pressure is to give you different results, varying by the following factors.
www.charmcare.com Pain and numbness by tightening the cuff This product needs to be tightened until the arterial blood flow is temporarily stopped. In such a case, you may feel pain or numbness. However, you will be ok when you take it off for a while. Blood pressure management at home You can check the fluctuations of your daily blood pressure results by keeping track of them and your daily routine as well. And also, it is more helpful to consult with your physician.
www.charmcare.com Automated Electronic Sphygmomanometer Oct. 26, 2017 Charmcare Co., Ltd. www.charmcare.com Charmcare is not responsible for loss of use or any indirect or incidental damages or any other losses.
www.charmcare.com Manufacturing license number: 2130 Product License number: 17-4808 FDA Registered Establishment Number : 3006056594 Product Name: Automated Electronic Sphygmomanometer, Model Name: H2-BP Packing unit: ea, Weight: 46 g Internal battery: LI-ION POLYMER, 3.
www.charmcare.com FCC ID: 2AUYU-4A01 FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.