The Federal Communication Commission Statement This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communication.
Programming Menu V3.9 Notice The manufacturer shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages in connection with the furnishing, performance or use of use the publication.
Contents Chapter 1 Description ............................................................ 3 1.1 General ................................................................ 3 1.2 Introduction ......................................................... 4 1.3 Codes Read .......................................................... 4 1.4 Installation ........................................................... 4 1.5 Pin Assignment .....................................................
6.9 Setup Insertion.................................................. 62 6.10 Scanning Line Selection for Multi Parallel lines modes ........................................................................ 65 Chapter 7 Bluetooth Configuration.................................... 66 7.1 Scanner Mode ..................................................... 66 7.2 Out of Range ....................................................... 67 7.3 Sleep Mode ......................................................... 68 7.
Chapter 1 Description 1.1 General Thank you for purchasing this barcode scanner with an advanced and versatile decoder. The decoder works with variety of barcode types, reading devices, and computer interfaces. It discriminates over twenty different symbologies automatically. This menu provides an easy way to configure the decoding options and interface selections by scanning bar codes listed in the menu.
1.2 Introduction The Decoder is an advanced and versatile decoding facility for barcoding systems .It works with variety of bar code types, reading devices, and computer interfaces. It discriminates about twenty different symbologies automatically. This menu provide an easy way to config the decoding options and interface selections by scanning bar codes listed in the menu. 1.3 Codes Read .
Power supply for RS-232C scanner There are 3 ways to supplying the power, use external +5V power supply, use optional power cable (KBDC) which taking the power from KB wedge or if the host supports +5V power from pin 9. Installing the scanner to the Host System 1. Turn off the host system. 2. Connect the power if needed. 3. Connect to the proper port on the host system. 4. Turn on the host system.
1.5 Pin Assignment A> Input Port for Mini Decoder DB 9 Male Pin No. Wand / CCD / Slot Reader Laser Scanner 1 N.C. S.O.S. 2 DATA DATA 3 N.C. N.C. 4 N.C. N.C. 5 N.C. TRIGGER 6 N.C. P. E. 7 GND GND 8 SHIELD SHIELD 9 +5V +5V 1 5 6 9 B> Output Port 1. PC Keyboard Output DIN 5 MALE DIN 5 FEMALE Pin No. Function Pin No. Function 1 HOST CLK 1 KB CLK 2 HOST DATA 2 KB DATA 4 GND 4 GND Vcc(+5V) Vcc(+5V) 5 5 1 3 4 3 5 1 5 2 4 2 MiniDIN 6 MALE Pin No.
Power Lead 6 7 3 1 8 8 5 2 5 2 4 7 4 7 6 3 1
Chapter 2 Configuration - General 2.
2.2 Loop of Programming The philosophy of programming parameters has been shown on the flow chart of 2.1. Basically user should 1. Scan Start of Configuration. 2. Scan all necessary labels for parameters that meet applications. 3. Scan End of Configuration to end the programming. 4. To permanently save the settings you programmed, just scan label for Save Parameters. 5. To go back to the Default Settings, just scan label for Set All Defaults. 2.
2.4 Main Page of Configuration Save Parameters %$ +/0 Recall Stored Parameters %$ + / 1 Set AII Defaults %$ + / 2 Start Configuration %$ + / 3 End Configuration %$ + / 4 Abort Configuration %$ + / 6 Version Information %$ + / 5 Save Parameters The parameter settings will be saved permanently. Recall Stored Parameters Replace the current parameters by the parameters you saved last time. Set AII Defaults Set all the parameters to the factory default settings.
Chapter 3 Interface and Reading Mode Selection 3.
3.
Ch.4 Communication Parameters 4.
B> Set Up Data Bits 7 Data Bits <8 Data Bits> %0Y80 C> Set Up Stop Bits %0Y8 8 <1 Bit> 2 Bits %0YO8 %0 YO0 13
D> Set Up Parity Even %0YN7 %0YN 2 Odd Mark %0YN3 %0YN1 Space %0 YN0 E Handshaking RTS/CTS Enable %01 8 8 %0180 ACK/NAK Enable %01 4 4 XON/XOFF Enable %0 1 4 0 %03 K4 %03 K0 14
4.
B> Upper/Lower Case %03 3 0 Upper Case %03 3 1 Lower Case %03 3 2 C> Caps Lock Detection Enable %0 X8 8 %0 X80 D> Send Character by ALT Method Enable %0 3O 8 E> Select Numerical Pad %03O0 ON %01 K4 %01 K0 16
4.
B> Time-out Between Characters <0 ms> %0070 5 ms %0071 10 ms %0072 25 ms %0073 50 ms %0074 100 ms %0075 200 ms %0076 300 ms %0077 18
4.
Ch.5 Bar Codes & Others 5.
Interleave 25 OFF %0GO8 Industrial 25 ON %0GO0 %0HO8 %0HO0 Matrix 25 ON %0 I O8 %0I O0 CODE 93 ON %0KO8 %0KO0 CODE 11 ON %0LO8 %0 L O0 China Postage ON %CMO8 %0 MO0 MSI/PLESSEY ON %CNO8 %0 NO0 21
Code 2 of 6ON %0 PO8 %0 POC LCD25 ON %0QO8 %0QO0 Telepen ON %0TO8 %0TO0 Reserved5 ON %0RO8 %0RO0 Reserved6 ON %0SO8 %0SO0 22
GS1 DataBar Omnidirectional ON %0UO8 %0UO0 GS1 DataBar Limited ON %0VO8 %0VO0 GS1 DataBar Expanded ON %0WO8 %0WO0 Select All Bar Codes %1 A/+ 23
5.
B> Supplemental Set Up Transmit 2 Code %0B3 3 Transmit 5 Code %0B3 1 Transmit 2&5 Code %0B3 2 %0B3 0 C> Check Digit Transmission UPC-A Check Digit Transmission OFF %0 AI2 UPC-E Check Digit Transmission %0AI 0 OFF %0 BI2 EAN-8 Check Digit Transmission %0BI0 OFF %0A88 EAN-13 Check Digit Transmission %0A80 OFF %0AH1 ISSN Check Digit Transmission %0AH0 OFF %0BK4 %0BK0 25
5.
D> Decode Asterisk Enable < Disable> %0E2 2 %0E20 E> Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths. %4 E1 + Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A) 3. 1st Set Complete %4E00 %4E01 1. 2nd Set Begin 2.
5.
D> Set Up Code Length To set the fixed length 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths. %4 E1 + Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A) %4F00 3. 1st Set Complete %4F01 1. 2nd Set Begin 2. Decimal Value (Appendix A) 3.
5.
D> Set 8p Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths. %4G1+ Fix Length (2 Sets Available> 1.1st Set Beg 2. Decimal Value (Appendix A) %4G00 3. 1st Set Complete %4G01 1.2nd Set Begin 2. Decimal Value (Appendix A) %4G00 3.
5.6 IndustriaI 25 Parameters A> Reading type IATA25 Enable %0H44 %0 H40 B Check Digit Transmission Calculate Check Digit & Transmit %0HN3 %0HN7 Calculate Check Digit & Not Transmit %0HN5 C> Set Up Code Length To set the fixed length 1. Scan the “Begin“ label of the desired set. 2. Go the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set.
%4 H1+ Fix Length (2 Sets Available> 1. 1st Set Begin 2. Decimal Value (Appendix A) 3. 1st Set Complete %4 H00 %4 H01 1. 2nd Set Begin 2. Decimal Value (Appendix A) %4H00 3. 2nd Set Complete %4 H02 Minimum Length 1. Begin 2. Decimal Value (Appendix A) %2 + - / 3.
5.7 Matrix 25 Parameters A> Check Digit Transmission %0I N3 Calculate Check Digit & Transmit %0I N7 Calculate Check Digit & Not Transmit %0IN 5 B> Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
%4 I1 + Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A) %4 I0 0 3. 1st Set Complete %4 I0 1 1. 2nd Set Begin 2. Decimal Value (Appendix A) %4 I0 0 3. 2nd Set Complete %4 I0 2 Minimum Length 1. Begin 2. Decimal Value (Appendix A) %2 + - / 3.
5.
C> Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths. %4 J 1 + Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A) %4J00 3. 1st Set Complete %4J01 1. 2nd Set Begin 2. Decimal Value (Appendix A) %4J00 3.
5.9 Code 93 Parameters A> Check Digit Transmission %0KN4 Do Not Calculate Check Digit %0KN3 B> Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
%4 K1 + Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A) %4 K0 0 3. 1st Set Complete %4 K0 1 1. 2nd Set Begin 2. Decimal Value (Appendix A) %4 K0 0 3. 2nd Set Complete %4 K0 2 Minimum Length 1. Begin 2. Decimal Value (Appendix A) %2 + - / 3.
5.10 Code 11 Parameters A> Check Digit Transmission Calculate Check 1 Digit & Transmit %0L N3 %0 LN 7 Calculate Check 1 Digits & Not Transmit Calculate Check 2 Digits & Transmit %0 LN 5 %0L N6 Calculate Check 2 Digits & Not Transmit %0 L N4 B> Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3.
%4L 1 + Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A) %4L00 3. 1st Set Complete %4L01 1. 2nd Set Begin 2. Decimal Value (Appendix A) 3. 2nd Set Complete %4L00 %4L02 Minimum Length 1. Begin 2. Decimal Value (Appendix A) %2 + - / 3.
5.11 MSI/PLESSEY Code Parameters A> Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit & Transmit %ONN3 %ONN7 %ONN5 B> Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
%4 N1 + Fix Length (2 Sets Available) 1. 1st Set Begin 2. DecimaI VaIue (Appendix A) %4 N0 0 3. 1st Set Complete %4 N0 1 1. 2nd Set Begin 2. DecimaI VaIue (Appendix A) 3. 2nd Set Complete %4 N0 0 %4 N02 Minimum Length 1. Begin 2. Decimal Value (Appendix A) %2 + - / 3.
5.12 Code 2 of 6 Parameters A> Check Digit Transmission Calculate Check Digit & Transmit %0 PN3 %0PN7 Calculate Check Digit & Not Transmit %0PN5 B> Set Up Code Length To set the fixed length: 1. San the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
%4 P1+ Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A) %4 P00 3. 1st Set Complete %4 P01 1. 2nd Set Begin 2. Decimal Value (Appendix A) %4 P00 3. 2nd Set Complete %4 P02 Minimum Length 1. Begin 2. Decimal Value (Appendix A) %2 + - / 3.
5.13 LCD25 Parameters A> Check Digit Transmission Calculate Check Digit & Transmit %0QN3 %0QN7 Calculate Check Digit & Not Transmit %0QN5 B> Setup Code length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
%4 Q1 + Fix Length (2 Sets Available) 1. 1st Set Begin 2. Decimal Value (Appendix A) %4Q00 3. 1st Set Complete %4Q01 1. 2st Set Begin 2. Decimal Value (Appendix A) %4Q00 2. 2nt Set Complete %4Q02 Minimum Length 1. Begin 2. Decimal Value (Appendix A) %2 + - / 3.
5.
%4T1+ %4T00 %4T01 %4T02 %2%+-/ 3.
5.
%0 V88 Don‘t Transmit Application ID Transmit Symbology ID %0V80 %0 V4 4 %0 V4 0 C> GS1 DataBar Expanded Parameters Transmit Symbology ID %0 W4 4 %0W4 0 51
Ch.6 Miscellaneous Parameters 6.
Belgium %0 ZVA Portuguese %0ZVB Denmark %0 ZVC Netherlands %0 ZVD Turkey %0 Z VE Reserved2 %0 ZVF 53
6.2 Bar Code ID ON %0 0 H1 %0 0 H0 Default %9 1 3 + With this function ON, a leading character will be added to the output string while scanning code, user may refer to the following table to know what kind of bar code is being scanned. Please refer to the table below for matching code ID of codes read in.
UPC-A UPC-E %9 1 A+ EAN-13/JAN-13 %9 1 B+ EAN-8/JAN-8 %9 1Y+ %9 1Z + CODE 39 CODE 128 %9 1 E+ CODABAR/NW7 %9 1 F + Interleave 25 %9 1 J + %91G+ Industrial 25 Matrix 25 %9 1 H+ %9 1 I + CODE 93 CODE 11 %9 1 K+ %9 1 L + ChinaPostage MSI/PLESSEY %9 1 M+ %9 1 N+ 55
Code 2 of 6 %9 1 P+ Telepen %9 1 T + LCD25 GS1 DataBar Omnidirectional ON %9 1 Q+ %9 1 U+ GS1 DataBar Limited ON %9 1 V+ GS1 DataBar Expanded ON %9 1W+ Reserved5 %9 1R+ Reserved6 %9 1 S+ 56
6.3 Reading Level Bar Equals High %0 3 I 2 6.4 Accuracy %0 3 I 0 <1 Time> 2 Times (V-1040/LG700) %0 1 3 0 3 Times %0 1 3 1 4 Times %0 1 3 2 %0 1 3 3 6.
6.6 Sensitivity of Continuous Reading Mode A> Quick Setting: Slow %0 3 8 8 %0 3 8 0 B> Same Code Delay Reading Interval Following code sequences represent the length of time before a barcode can be rescanned at continuous and flash reading mode. The value can be defined from 1-50 and they represent 100ms to 5 seconds in 100ms interval. Default value is 3 (0.3 seconds). To setup same code delay reading interval: 1.Scan the "Begin" label 2.
6.7 Reverse Output Characters Enable %03H0 Enable %03H1 6.8 Setup Deletion To setup the deletion of output characters: Repeat the steps 1 – 6 to set additional deletion. 1. A> Select Deletion Set Number 1st Set %800+ 3. 2. 2nd Set 3rd Set %801+ %802+ 5. 4. 4th Set 5th Set %803+ %804+ 6.
B> SymboIogies Selection UPC-A UPC-E %8 1 A+ EAN-13/JAN-13/ISBN-13 %8 1 B+ EAN-8/JAN-8 %8 1 Y+ %8 1Z + CODE 39 CODE 128 %8 1 E+ %8 1 F + CODABAR/N97 Interleave 25 %8 1 J + %8 1 G+ Industrial 25 Matrix 25 %8 1 H+ %8 1 I + CODE 93 CODE 11 %8 1 K+ %8 1 L + China Postage MSI/PLESSEY %8 1 M+ %8 1 N+ 60
Code 2 of 6 % 81P+ Telepen LCD25 %81T+ GS1 DataBar Omnidirectional %81Q+ GS1 DataBar Limited %81U+ GS1 DataBar Expanded %8 1 V+ All Codes % 81W+ %8 1 S+ None % 814+ C> Character Position to be Deleted 1. Decimal Value (Appendix A) 2. Complete %8 20+ D> Number of Characters to be Deleted 1. Decimal Value (Appendix A) 2.
6.9 Setup Insertion To setup the insertion of output characters 1. Scan the label of the desired set. 2. Scan the label of the desired symbology. 3. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the desired position to be inserted. 4. Scan the “Complete“ label of “Character Position to be Inserted“. 5. Go to the ASCII Tables in Appendix B or Function Key Tables in Appendix C, scan label(s) that represents the desired characters to be inserted. 6.
B> SymboIogies Selection UPC-A UPC-E %51A+ EAN-13/JAN-13/ISBN-13 %51B+ EAN-8/JAN-8 %51Y+ %51Z+ CODE 39 CODE 128 %51E+ %51F+ CODABAR/NW7 Interleave 25 %51J+ %51G+ Industrial 25 Matrix 25 %51H+ %51I+ CODE 93 CODE 11 %51K+ %51L+ China Postage MSI/PLESSEY %51M+ %51N+ 63
Code 2 of 6 Telepen %5 1 P+ %5 1 T + LCD255 GS1 DataBar Omnidirectional %51Q+ GS1 DataBar Limited %5 1 U+ GS1 DataBar Expanded %5 1 V+ %5 1 W + All Codes %5 1 S+ None %5 1 4 + C> Character Position to be Inserted 1. Decimal Value (Appendix A) 2. Complete %5 2 0 + D> Characters to be Inserted 1. ASCII Table (Appendix B) 2.
6.
Ch7. Bluetooth Configuration BT Parameter Set Default 7.1 Scanner Mode A>Setup SPP Master Mode Please follow the steps to setup the communication between the scanner and dongle. 1) The scanner must scan “SPP Master Mode” barcode to set the scanner in master mode. 2) Scan the Bluetooth MAC address code located on the bottom of the dongle. 3) When the Bluetooth MAC address code was successfully scanned, scanner will sound 3 short beeps with green LED flash once.
C>Setup HID Slave Mode HID Slave Mode To setup the communication between the scanner and Bluetooth HID profile application device, follow the steps. 1) The scanner must scan “HID Slave Mode” barcode to set the scanner in HID slave mode. 2) When control the Bluetooth device to search the scanner, enter pin code to setup pairing. You can scan number barcode on Appendix D, “Decimal Value Table II” number 0~9, to setup. 3) When scanner is successful connected, scanner blue LED will also blink with up-tone.
7.3 Sleep Mode The scanner is equipped with sleep mode function to save battery energy when the scanner is not used for 1 minute or 10 minutes. During sleep mode, all the functions and connection will be halted until pressing the trigger button. The communication with dongle or Bluetooth device will be reconnected. Sleep Mode 1 min. ON Sleep Mode10 min. ON 7.4 Batch Mode “***” means “Quick Setting Label”.
7.5 Firmware Version Display the firmware version of the scanner, please scan below barcode.
Appendix A Decimal Value Table 0 1 2 3 4 5 6 7 8 9 70
Appendix B ASCII Table NULL 00 SOH STX ETX 01 02 03 ENQ ACK 05 C6 0A 0B 0D 0E 10 11 13 14 16 17 EM SUB ESC 19 1A RS SYN ETB CAN 1B DC3 DC4 NAK 18 DLE DC1 DC2 15 CR SO SI 12 LF VT FF 0F BEL 07 08 0C 04 BS HT C9 EOT FS GS 1C 1D 1E US 1F 71
SPACE 20 ! “ # 21 22 23 % & 24 25 26 27 28 2A 2B 2D 2E 30 31 33 34 36 37 39 3A > 9 : ; 3B 6 7 8 38 3 4 5 35 0 1 2 32 - .
@ A 40 B C 41 42 43 E F 44 45 46 47 48 4A 4B 4D 4E 50 51 53 54 56 57 59 5A ^ Y Z [ 5B V W X 58 S T U 55 P Q R 52 M N O 4F J K L 4C G H I 49 D \ ] 5C 5D 5E _ 5F 73
a ` 60 61 b c 62 63 e f 67 68 69 6A 6B m n o 6D 6E 6F j k l 6C g h i p 7C q s r 71 72 t u 73 74 75 v w 76 y x 77 78 z 79 | ﹛ 7A 7B ~ 64 65 66 d } 7C 7D 7E DEL 7F 74
Appendix C Function Key Table F1 F2 C0 C1 F3 C2 F4 F5 C3 C4 F6 C5 F7 F8 C6 C7 F9 C8 F10 F11 C9 CA F12 CB Insert Delete CC CD Home CE Page Up Page Down CF D0 End D1 Left Right D2 D3 Up D4 Down D5 75
Appendix D Decimal Value Table II 0 1 2 3 4 5 6 7 8 9 Enter 76
All above programming are subject to change without notice.
%$+/0 %$+/1 %$+/2 %$+/3 %$+/4 %$+/6 %$+/5 Ver3.