Cordless IP Phone User Manual For model: 9700IP/9702IP NDC2110S/NDC2210S Version: V1.
1. INTRODUCTION ................................................................................................... 5 1.1HARDWARE OVERVIEW ...........................................................5 1.2 SOFTWARE OVERVIEW............................................................5 2 PHONE MENU SETTINGS .................................................................................... 7 2.1 KEY FEATURES .....................................................................
4.6.3 User Management ................................................................. 30 4.6.4 System Actions .................................................................... 31 4.6.5 DECT .............................................................................. 31 5 SHORTCUT KEYS ............................................................................................ 32 6 WARNING ..............................................................................................................
The phone started, get Provisioning Server address by DHCP Server, then the phone LED lights flashing, and issued a "beep beep" prompt tone, "Config ID".
1. INTRODUCTION This is the 9602IP network telephone user manual. Before the use of 9602IP phone,you need to make some phone configuration for normal use. This book illustrateshow to use keyboard and Web phone service configuration page. 1.1HARDWARE OVERVIEW The default WAN port is a DHCP client, the user connects it to the ADSL orWAN port switch, LAN port connects to the computer; you can use the administratorusername "admin" and password"admin"to set the login password. Only WAN port supports POE. 1.
Call forward Caller ID Web Browser Keypad DTMF Firmware Upgrade IN Band RFC2833 SIP Info TFTP HTTP FTP HTTPS
2 PHONE MENU SETTINGS Using the web configuration page: familiar with the PC usercan use the method to configure the phone. Sequentially press the"**47#" button, then the phonewill voice broadcast addressIP. Directly in the browser address bar entering the address of theIP phone can log in web page, enter the login name: admin,password: admin 2.1 KEY FEATURES The user can use the table below to confirm the key and hardware function.
Mute Conversation Stand-by Conversation Stand-by Stand-by Stand-by Conversation Redial Dialing Hold/Conf Conversation Volume+ VolumeLine1 Line2 Two lines on hold Increase the receiver volume Increase the ringer volume Decrease the receiver volume Decrease the ringer volume Line1 state (only for two-line model) Line2 state (only for two-line model) Mute The last number redial and call Hold or release hold or Park key Achieve Conference function (only for two-line model) Speaker Conversation Convers
3 THE OPERATION METHOD OF TELEPHONE 3.1 HOW TO MAKE A PHONE CALL? You could make a phone call after the phone configuration items are set up.Please check if the cable is properly connected before use. 3.1.1 Basic call 1. Making the call by handset After the handset is placed off-hook, dial and use “#”key as the end dialing symbol. 2. Making the call by speakerphone After the phone is placed off-hook, dial and use “#”key as the end dialing symbol. 3.1.2Hold Key 1.
3.1.4 Mute During the call, if you do not want to let them hear your own voice, youcan press "Mute"key, so that the other party cannot hear your voice, andyou can hear the sound of other end. 3.1.5 Memory Key In addition to serving as a storage function, but also can be used as hold, DND,transfer and conference function. See the web call feature function set. 3.1.
“Message” LED on base unit will stop blinking and the “Message” LED on handset will also stop blinking and emit the prompt sound of successful registration. Note: each base unit can register up to 5 handsets. 3.1.11 Toggle between Base Unit and Handset When the base unit is in conversation, press “Line1”/“Line2” key on handset, the call will switch over to the handset. If the handset is in conversation, press “SPEAKER” key, the call will switch over to the base unit.
4.2 NETWORK SETTING You can get the network information of phone in the page. 4.2.1 WAN Setting WAN port setting page. WAN port supports the static IP, dynamic allocation IP and PPPoE.
4.2.1.1 Basic Setting Basic Setting Network Mode Select the network mode of WAN port; the default is DHCP Link mode Configure the WAN port network connection mode Primary DNS Set the main DNS address Secondary DNS Set the secondary DNS address 4.2.1.2DHCP If your local network has a DHCP server, 3302IP phone can get WAN networkinformation from the DHCP server.
4.2.1.3Static IP Setting Static IP setting(WAN port network mode is set to Static IP) Set static IP address Static IP Address Subnet Mask Set subnet mask with static IP Default Gateway Set the default gateway with static IP 4.2.1.4 PPPoE Setting PPPoE Setting (Required if Network Mode is set to PPPoE) Set the PPPoE user account User Account Set the PPPoE account password Password 4.2.1.5 802.1x settings 802.1x settings 802.1x_Enable 802.1x_UserName Enable or disable 802.1x authentication 802.
Note: if the user wants to access the phone through the WAN port, then he / she must use the new IP address to accessthe phone after changing IP address of WAN port. 4.2.2LAN Settings LAN port setting interface 4.2.2.
4.2.2.2 NAT NAT IP Address IP address of LAN port Subnet Mask Subnet Mask DHCP Server DHCP server is enabled or not IP Pool Start IP address assignment startaddress IP Pool End IP address assignment endaddress MAX Leases Maximum release time DNS Relay DNS relay is enabled or not 4.3 VOIP SETTING You can get SIP account information and registrationstatus of the phone through the page. 4.3.1 Primary Register Configure the SIP registration information of phone in the below page.
Register Server Use Service Enable or disable SIP registration Display Name Set the displayed name of phone's SIP account User Name Set the username (SIP account) Authorization User Name Confirm the SIP account Password Set the password of SIP account Register Server Port Set the port No.
Protocol Control Disable: the phone prohibits MWI function. Even if it receives a NOTIFY from server that there is a new voice mail, the phone will not have a prompt. MWI Subscribe Enable(Subscribe): the phone enables MWI function and will send SUBSCRIBE. If it receives a NOTIFY from server that there is a new voice mail, the MWI LED on phone will blink to give a prompt. Enable(No Subscribe): the phone enables MWI function but will not send SUBSCRIBE.
Audio Setting Sound and Volume Control Handset Configure the handset output volume. The control range is 1~7. The default is 5. Speaker Configure the speakerphone output volume. The control range is 1~7. The default is 5. Ring Tone Configure the ringer volume. The range is 1~7. The default is 4. Signal Standard The signal standard. There are 12 categories in total.
l iLBC l G.722 Packet Data Size The packet data size is 20mS by default. IBLC 15.2k iLBC 15.2kbit/s is enabled or not. The default is disable. G.723.1 5.3k G.723.1 5.3kbit/s is enabled or not. The default is disable. Voice VAD/CNG Voice VAD Enable or disable Mute detection function CNG Enable or disable the comfortable noise. Codec ID Settings DTMF Payload(RFC2833) DTMF payload. The default is 101. 4.3.
Call Feature Programmable Keys&MWI Touchlite 1. Set the number in speed dial key. Mem1~Mem10 2. Set the second function. Each memory can be arbitrarily set as Hold, DND, Transfer, Conference, Multicast Paging MWI Touchlite Set the number in shortcut key for voice message pickup. Park Mode Enable or disable Park function. Hold key Active Set the Call Park number. In Park mode, when one line of phone is in call, press HOLD key to call the number. Hold key Idle Set the Call Park number.
The set range is 1-9s, for example 3s, the hotline number will be sent out immediately after 3s with the phone off-hook and without pressing any key. As long as any key is pressed within the set time, the time counting will stop. Enable or disable auto answer function. If enabled, you could set 5 auto answer phone numbers for incoming call. Auto answer Auto Answer Time Out Enable the auto answer function after timeout. The set range is 0~30s, the default is 5s.
Dialing Rules Configuration Entry Name Dialing Rules Configuration User Define Rules Description 1. Set the end of dialing rules, there are 2 kinds to choosefrom: End with “#”. Timeout: Timeout setting. Set the waiting timefor dialing end, the unit is second, the defaultis5s. The default is "#" as the end of the dial. 2. 60mins。Redialing timeliness: The default is 60mins,redial will be invalid. Maximum of 60mins can be set. Users can add 10 custom dialing rules.
4.3.5 Multicast Paging You can use the multicast function that will simply, conveniently and efficiently send the timely notice to each member of the multicast group. The multicast key is set on the telephoneto send the multicast RTP stream to the pre-configured multicast address. Throughthe configuration monitoring multicast address on the phone, listen and play theRTP stream sent by the multicast address, the RTP stream multicast process does notinvolve SIP signaling.
The multicast voice coding format:0:G.711a; 1:G.711u; 2:G.723; 3:G.729; 4:iLBC; 5:G.722 Multicast Paging Codec Multicast Listening listening Address You can set to listen up to 10 different multicast addresses on the phone which can be used to receive the multicast RTP stream sent by them. If the priority of incoming multicast RTP stream is lower than the priority of current call, the phone will automatically ignore the multicast RTP stream.
QoS Setting Entry Name Voice VLAN Description Enable or disable Voice VLAN function. The default is disable. Voice VID(TAG) The Voice Video Tag. The range is 2~4094. The default is 136. User Priority User priority.The default is 0. Data VLAN Enable or disableData VLAN function. The default is disable. When it is enabled, LAN port will operate in the bridge mode. Data Priority Data label. The range is 2~4094. The default is 137. User Priority User priority.The default is 0.
Provisioning Provision Options DHCP Options Support DHCP Options parameter or not. Auto Redirection Support Auto Redirection or not MAC File Support that the Config. filename is MAC address or not Config ID Support that the Config. filename is config ID or not Fireware Update Support the firmware upgrade Notify Reboot Enable or disable Notify Reboot. After enabled, it is divided into 2 cases, one needs the authentication, the another does not need.
ConfigID Update Time 0-24, 0 - Disable, 1-24 hour selects any hours among 1-24 and generates a random number as the minute of upgrade among 0~60 and delays a few seconds to begin to detect if Config ID file is updated. Firmware Update Time 0-24, 0 - Only check at reboot, 1-24 hour selects any hours among 1-24 and generates a random number as the minute of upgrade among 0~60 and delays a few seconds to check if there is any firmware update.
Server Port Set the port # of syslog server. The default is 49494. default The default of logintelval is 0. Events only Log information print interval is 1min. Events status plus periodic inteval Logint is the setting range of lower interval. Log interval time setting. 4.6.2 Time Settings Time Settings Time Settings Information SNTP SNTP server enable or disable. Server Address SNTP server address: the default is 0.pool.ntp.
Enable Daylight Daylight savings enable or disable. Time Shift(minutes) Time difference (minute) Daylight Savings Start Dates Month Daylight Savings Start Month Week of Month Week of Month Day Day of Week Hour Hour of Day Daylight Savings Stop Dates Month Daylight Savings Stop Month Week of Month Week of Month Day Day of Week Hour Hour of Day 4.6.3 User Management Set the user information.
Administrator Password Verify Password Set the password for webpage login in the identity of administrator. The default is admin. Input the administrator password again for verification. Remote Administration CetisAdmin User CetisAdmin Password Verify Password Set the username of remote administrator. The default is admin. Set the login password of remote administrator. The default is admin. Input the administrator password again for verification. 4.6.4 System Actions System operation.
Power Level Select the power level of registered handset. The power level is related to the receiving range. The level 0 is minimum, level 7 has the maximum receiving range. Frequency Select the DECT frequency band: select the different countries. 5 SHORTCUT KEYS 1. * * 47 #, Broadcast the current ip address of the phone. 2. * * 39 #, Broadcast the current software version of the phone. 3. * * 85 #, Broadcast the current phonevlan ID. 4. * * 83 #, Broadcast current tftp server address. 5.
FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
age and health. This device and its antenna must not be colocated or operating in conjunction with any other antenna or transmitter. This product has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in FCC/OET Bulletin 65 Supplement C (2001) and IEEE 1528.
exceed the exposure limit established by the ISEDC, tests for each device are performed in positions and locations as required by the ISEDC. For Base This equipment complies with ISEDC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.
celui-ci doit être soumis à des tests de certification par l’ISEDC lesquels n’excèdent aucunement la limite d’exposition issue par l’ISEDC, lesquels sont des tests effectués sur chaque appareil dans des positions et endroits requis par l’ISEDC. Pour la base Cet équipement est conforme avec les limites d’exposition à la radiation de l’ISEDC émises dans un environnement contrôlé. Cet équipement devrait être installéet fonctionnel avec un minimum de distance entre le radiateur et votre corps d’au moins 20 cm.