CT-DECT Case with GSM and Radio communication Description and Operation CT-DECT Case
Contents 1. Important safety instructions ..............................................................................................................4 2. Description .........................................................................................................................................5 2.1 Purpose ......................................................................................................................................5 2.2 Overview CT-DECT Case............................
Important Notes for operation of the CT-DECT System in the USA Please note that any changes or modifications not expressly approved by the party responsible for compliance will void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Important Information for Users of the CT-DECT transceivers CT-DECT transceivers that are not intrinsically safe (explosion-protected) and therefore do not have any special hazardous duty marking must never be used in potentially explosive atmospheres. Unprotected CT-DECT transceivers can trigger explosions unintentionally in these areas.
z z z z z z z z z z When driving a car, do not use the radio because it may distract you from the other traffic. Never use a CeoTronics product (headset, insert earphone, induction receiver etc.) that will impair your hearing. Transmit only when it is necessary. Unnecessarily occupying a channel can prevent the transmission of vitally important information. Charge rechargeable batteries only with the appropriate suitable CeoTronics charger.
Figure 1 System overview (Example) 6
2.2 Overview CT-DECT Case Basic Configuration - one or two pluggable CT-DECT Conference (4) (FP) (Art. No.1410165; is not included in the scope of delivery) for each four participants with CT-DECT transmitter-/receiver device standard - one changeable Power supply with Li-/Ion battery (Art. No.0913024) - one mains adaptor (Art. No.0913025) - connector-and control panel at the outside of the CT-DECT Case The CT-DECT Case is equipped with roles and an extendable handle.
Figure 3 CT-DECT Case 8
a b c d 2.3 e Subscription „1“ button for subscription of max. four CT-DECT Multi Standard (PP) to the CT-DECT Conference (4) (FP) „1“ f 9-pin plug for connection of accessory (e.g. MP3 recorder) g Subscription „2“ button for subscription of max.
3. Commissioning and operation 3.1 Connection of the CT-DECT Case The Li-/Ion battery in the Power Supply of the CT-DECT Case must be sufficiently charged. Connect the accessories at the 9-pin socket at the CT-DECT Case, if desired. The 9-pin plug of the connection cable (Fig. 3/f) has a protection against torsion. Î NOTE Keep the CT-DECT Case closed while in use outside! 3.
3.5 GSM – Communication The GSM-phone does not have to be taken out for switching on from the case. In the foam pad an opening is cut out for switching on the GSM-phone (Figure 4). The GSM phone must be equipped with an automatic call accepted and the call accepted must be switched on. If the GSM-phone in the CTDECT Case is called, the call is accepted automatically and all mobile participants in the DECT-System can talk with the external caller.
5. Charging and changing Power Supply with the Li-/Ion battery 3.6 V/6 Ah 5.1 General The mains adaptor supplied the CT-DECT Case with power and the Li-/Ion battery and the battery of the GSM-phone are charged in the same time. The mains adaptor must be attached to a professionally installed energized plug socket. The CT-DECT Case can be charged also by the delivered car mains adaptor (Figure 6) and supplied him with power.
Charge and change batteries only in surroundings, where no explosive gasses, steams or dusts can be available in connection with oxygen. z Do not charge batteries outside. 5.2 Changing the Power Supply of the CT-DECT Case Open the cover of the case for changing the power supply. Pull out the Power Supply carefully and solve the 26-pin plug with help of a screwdriver. Reinstall the new power Supply in reverse order. Figure 7 6. Maintenance 6.
7. Installation and Uninstallation of the components CT-DECT Conference (4) (FP), GSM-phone and Two-way radio 7.1 CT-DECT Interface Open the cover of the case for changing the CTDECT Conference (4) (FP). Pull out the CT-DECT Conference (4) (FP) „1“ or „2“ carefully and solve the plug connection. To open the plug connection pull in direction of arrow. Do not twist or break the plug connection. Reinstall the new CT-DECT Conference (4) (FP) in reverse order.
8. On-air subscription of CT-DECT Case and CT-DECT Multi Standard (PP) 8.1 General Î NOTE z Subscribing CT-DECT devices standard (PP) into a CT-DECT device base (FP) is usually only necessary if a CT-DECT system is put into operation for the first time or if individual CT-DECT devices are replaced, e.g. after repairs. z A CT-DECT device standard (PP) can only be subscribed into a single CT-DECT devices base (FP), never into two or more simultaneously.
dard (PP) has to be subscribed again to the CT-DECT device base (FP) according to the subscription procedure. Once the subscription procedure has been successfully concluded, the identity of the communication participants is stored in the data memory of the device. The CT-DECT device standard (PP) stores one CT-DECT device base (FP). The CT-DECT device base (FP) stores the last four successful subscribed CT-DECT devices standard (PP). 8.
8.4 On-air subscription CT-DECT devices standard of group 1 In the following by way of an example the subscription of the max. four CT-DECT Multi Standard (PP) of group 1 to the CT-DECT Case is described. 8.4.1 On-air subscription of the first CT-DECT Multi Standard (PP) of group 1 a. Ensure that the CT-DECT Multi Standard (PP) switched off and the CT-DECT Case is switched on. b. Prepare the first CT-DECT Multi Standard (PP) for the operation, leave it however switched off.
9. Technical Specifications Socket assignment: Socket Audio/Data 1 2 3 4 5 6 7 8 IF_IN1 IF_IN2 IF_OUT1 IF_OUT2 MP IN+ N.C Battery+ 9 IN- socket Power Supply -200mV/600Ω -200mV/600Ω -200mV/600Ω -200mV/600Ω -GPIO-Port active “1” -Power supply input 1 2 3 -Power supply for ext.
Notes 19
Germany and International Sales CeoTronics AG Adam-Opel-Str. 6 63322 Rödermark Tel. +49 6074 8751-0 Fax +49 6074 8751-676 E-Mail sales@ceotronics.com USA/Canada/Mexico France Spain CeoTronics, Inc. 300 Southport Circle, Suite 103 Virginia Beach, Virginia 23452 Tel. +1 757 549-6220 Fax +1 757 549-6240 E-Mail sales@ceotronicsusa.com CeoTronics Sarl Bât. Delta T Z.A. du Tuboeuf Allée des Pleus 77257 Brie Comte Robert Cédex Tel. +33 1 60183300 Fax +33 1 60286060 E-Mail ventes@ceotronics.fr CeoTronics S.L.