Installation Guide ZIGBEE HA Thermostat 3156105
Locating the Thermostat If this is to replace an existing thermostat, just use the existing thermostat location. If this is a new install follow these suggestions: Locate the thermostat about 5 ft. off the floor away from direct sunlight, lamps, radios, televisions, fireplaces, hot water pipes, or other heating or cooling sources. Do not locate the thermostat near doors to the outside or windows. Do not locate the thermostat in a damp area.
Install CentraLite Thermostat Place each wire in the appropriate wire terminal.
Install CentraLite Thermostat By default the CentraLite thermostat comes with a wiring jumper connecting the RH and RC power terminals. On most units only one power source is used and can be connected to both RH and RC. But if you have a millivolt system or other type of HVAC system it may require separate power sources for Heating and Cooling. In this case you will remove the jumper and separately power RC and RH.
Thermostat Overview Reset Switch Current Temp Wiring Terminal Setpoint Temp Setpoint UP Fan Indicator Zigbee Status Setpoint DOWN + 4 AA Batteries -
Testing Thermostat Operation After completing any necessary configuration make sure the thermostat is in Cool mode by pressing the MODE button until Cool is displayed at the bottom of the screen. Make sure the system is not calling for Cooling by setting the setpoint several degrees above the room temperature. Then check the Fan operation by pressing the Fan button. When the Fan indicator is illuminated without the Auto indicator then air should blow from the unit.
Join To Zigbee HA Network The CentraLite thermostat is intended to operate as part of a Zigbee HA network. The thermostat needs to be joined to the Zigbee HA network after installation. The first step in the join process is to make sure the Zigbee HA controller is in it’s join network mode. The CentraLite thermostat will attempt to join a Zigbee HA network upon power up or after pressing the Reset button(as long as it has not already been joined to another Zigbee HA network).
Thermostat Functions MODE button cycles between system modes: HEAT/COOL/AUTO/OFF FAN button toggles between Fan On Mode and Fan Auto Mode. If available it will cycle through multiple fan speeds. HOLD button will enable Hold function which locks out all scheduled system changes. This includes internal schedules and external schedules from a controller.
Thermostat Programming To enter programming mode: PRESS FAN and MODE buttons at the same time. Then press the UP ARROW button.. The clock display will change to indicate which programming mode you’re currently in. The display will start at 10:00. If there is ever any inactivity for more than 30 seconds the thermostat will automatically return to normal operation. Set digit up or down using up and down arrow buttons. Use HOLD button to move left one digit. Use MODE button to move right one digit.
Thermostat Programming 11:10(Type) 01: 02: 03: 04: 05: 06: 07: 08: 09: 10: 11: 12: 13: 1 Heat, 1 Cool(DEFAULT) 1 Heat, 2 Cool 2 Heat, 1 Cool 2 Heat, 2 Cool Heat Pump, Changeover Energized on Heat Heat Pump, Changeover Energized on Cool Heat Pump, Separate B and O Heat Pump, 1 Heat, 2 Cool, Changeover Energized on Cool Heat Pump, 2Heat, 1 Cool, Changeover Energized on Cool Heat Pump, 1 Heat, 2 Cool, Changeover Energized on Cool Heat Pump, 1 Heat, 2 Cool, Changeover Energized on Heat Heat Pump, 2Heat, 1 Cool
Thermostat Programming 12:21(System Mode) 00: Cooling Only(COOL and OFF modes only) 01: Cooling with Reheat 02: Heating Only(HEAT and OFF modes only) 03: Heating with Reheat 04: Full Mode(AUTO, COOL, HEAT, OFF) 05: Full Mode with Reheat(AUTO, COOL, HEAT, OFF) 06: Manual Mode(COOL, HEAT, OFF) (DEFAULT) 07: Auto Mode(AUTO, OFF) 13:10(Calibration) -09 to 09: Temperature Calibration(DEFAULT = 00) 14:11(Occupancy Differential) 00-99: Setback Differential 0.0 Degrees F to 9.
Thermostat Programming 15:21(Cool Mode Delay) 00-99: Minimum Delay in minutes for change into Cool Mode 15:31(Heat Mode Delay) 00-99: Minimum Delay in minutes for change into Heat Mode 16:11(Temperature Scale) 00: 01: Celsius Fahrenheit 16:21(Minimum Cool Time) 00-99: Minimum Time in Minutes Unit will run during a Cool Cycle 16:31(Minimum Heat Time) 00-99: Minimum Time in Minutes Unit will run during a Heat Cycle 16:41(Cool Maximum Runtime) 00-99: Maximum Continuous time the unit will run during a
Thermostat Programming 17:21(Display Type) 00: 01: 02: 03: Current Temperature Without Decimal Point Current Temperature With Decimal Point Setpoint Temperature Without Decimal Point Setpoint Temperature With Decimal Point 18:11(Cool Setpoint Upper Limit) 00-99: Upper limit of Cool Setpoint 18:21(Cool Setpoint Lower Limit) 00-99: Lower limit of Cool Setpoint 18:31(Heat Setpoint Upper Limit) 00-99: Upper limit of Heat Setpoint 18:41(Heat Setpoint Lower Limit) 00-99: Lower limit of Heat Setpoint 18:51(Low S
Thermostat Programming 21:10(Active Scan and Join Available Network) 22:10(Join Network) 23:10(Leave Network) 24:10(Status) 31:10(Set Clock Day) 32:10(Set Clock Hours) 33:10(Set Clock Minutes) 41:00(Reset) 42:00(Factory Reset) 51:00(Lock Keys) 52:00(Password)
Notes
www.centralite.com This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2)This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.