User Manual

Thermostat
Installation Guide
WARNING!
Must be installed by a
trained, experienced techni-
cian.
Thermostat Installation
24 Hour Technical Support
CentraLite Systems, Inc.
6420 Wall Street
Mobile, AL 36695
(877) 466 5483
Fax: (251) 607-9119
Supported Model
CentraLite Thermostat
3155100
Specifications and Supported Loads
The CentraLite thermostat can operate standalone but is
best used when part of the CentraLite Energy
Management System. This product is intended for
remote control by the CentraLite Energy Management
System.
Power: 24 VAC Class 2 Power Supply
Communications
2.4 GHz, 16 channel spread spectrum radio frequency
Electrical Ratings
All relay outputs are rated for up to 1 AMP
Wiring Specifications
18- to 22-gauge thermostat wire
Caution! Using this product in
any manner other than outlined in
this document voids your warranty.
CentraLite is not responsible for any
damage incurred as a result of mis-
use or abuse of this product. For
more details see the “Limited 5 Year
Warranty”
1. Detach thermostat backplate from thermostat.
2. Backplate can be mounted using drywall/plaster wall
anchors or attached to a wall mounted back box.
3. Before anchoring backplate to the wall bring , pull
wires through the hole in the center of backplate.
4. Place backplate over wall anchors and insert and
tighten mounting screws.
5. Attach wires appropriate to the diagram on the back
of this sheet.
6. To mount the thermostat to the backplate, align the 4
mounting tabs and press gently until the thermostat
snaps into place.
If you have questions about the installation of
the CentraLite thermostat please call CentraLite
technical support toll free at:
1-877-466-5483
Or visit the online helpdesk at:
www.centralite.com/helpdesk
Mounting Holes
Wire Hole
Mounting Holes
Wiring Terminal