User's Manual

AZELA ZIGBEE HA Appliance Module
4256050-RZHA,RZHAC
Rated: 120 VAC, 60Hz
Rated 8A General Purpose, 480W Incandescent
Warnings and Cautions:
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any of these instructions, consult a qualified electrician.
Unplug unit when servicing connected appliances.
Save this instruction sheet. It contains important technical data along with testing
and troubleshooting information which will be useful after installation is complete.
INTRODUCTION
The CentraLite Azela ZIGBEE HA Appliance Module
uses the Zigbee Home Automation(HA) communication
protocol to link with other Zigbee HA devices. Each
Appliance Module acts as a router for messages sent
through the Zigbee network.
FEATURES
Status LED
Load control from button on Appliance Module
Ease of installation
Compatible with other Zigbee HA certified level
controllers
RZHAC devices sense and report realtime load
current consumption
INSTALLATION
STEP 1
Attach the plug from the appliance to be
controlled into the receptacle of the
Appliance Module.
STEP 2
Attach Appliance Module to wall recepta-
cle. Verify that the receptacle is
powered. If the receptacle is powered by
a wall switch, the wall switch must be
kept ON at all times for the module to
operate properly.
STEP 3
To join the ZIGBEE HA Appliance Mod-
ule to a certified HA controller be sure
that the HA controller is open for joining.
If the Appliance Module has not been
joined to a network then press and hold
the Appliance Module button. The Appli-
ance Module will then attempt to join an
open HA network.
Upon a successful joining of the Appli-
ance Module to a Zigbee HA network the
status LED will blink 2 times. When the
Appliance Module powers up after being
joined to a Zigbee HA network, it will
blink 2 times.
4256050-RZHA,RZHAC
STEP 3 cont’d
If the Appliance Module will not join a Zigbee
HA network then:
Make sure the Appliance Module is pow-
ered up
Ensure the Appliance Module is within
RF range of a routing device
Make sure the target Zigbee network is
open for joining
STEP 4
Once the Appliance Module is joined to
the Zigbee HA network, use the certified
HA controller to configure the Appliance
Module.
STEP 5
If it becomes necessary to remove the
Appliance Module from a Zigbee HA
network then you must factory default the
Appliance Module. To factory default the
Appliance Module:
Remove the Appliance Module from the
wall receptacle
Press and hold the Appliance Module
button
Reinstall the Appliance Module into the
wall receptacle while holding the button
After 2 seconds the status LED will turn
ON
Once the LED is ON let go of the button
The Appliance Module will now be reset
to factory defaults and ready to join to a
Zigbee HA network.
www.centralite.com

Summary of content (2 pages)