User's Manual

UVC SANITIZING Cart
User Manual
Product No Voltage Input Wattage Product Size
CP101 AC110-240V 240W L264.2*W223.4*H626.7mm
This UVC decontamination chamber only for commercial use , such as in the Hotel,
Resorts,Shoppingmall,Office,Workspace,Meetingroom,Manufacturing
workshops,Medical&Dental
examrooms,Retail&commercialspaces,Hospitals,Schools,Bathrooms,Restaurants&Kithens ,Cr
uise Ships ,Military Bases etc., it was only used by professional person. The warning sign as
below shall be shown on the way to the fixture during operation.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
a) This equipment is designed for using with germicidal UV radiation sources. UV radiation can cause a risk of personal injury.
Overexposure can result in damage to eyes and bare skin. To reduce the risk of overexposure, this equipment must be operated
by professional person.
b) Maintenance and servicing of this UV equipment shall be operated by professional person. If the equipment needs to be in
operation during the maintenance or servicing work, pls contact the equipment manufacturer for PPE recommendations and
guidance.
c) Do not use this equipment for other purpose.
d) If using accessory, which is not recommended by the manufacturer, to the equipment, it may cause unsafe condition.
e) The equipment should be stored well to avoid any potential accidental damage after used.
Warning: Don't look at the disinfection light directly.
TECHNICAL SPECIFICATIONS:
Fixture power
240W
Ambient temperature
0~+40
UV lamp power
200W
Storage temperature
-10~+60
Input voltage
110-240Vac
Time shutdown
15S/60S
Peak wavelength
253.7nm
Power factor
0.9
Beam angle
360°
Weight
13.5kg
Life
60000Hrs
IP level
IP20
UV radiation intensity(1m)
1300uW/cm²
Color
White