Precautions for Use
Each unit of the charger comes with one piece each of the side and bottom brackets.
After you join two chargers together using these two brackets, one side bracket and
one bottom bracket will be left over. Keep these as spare for use in future.
Always disconnect the AC adaptor before joining multiple chargers together.
Specifi cations
1. Charging speci cations
Charging method : Constant-voltage constant-current charging
Charging time : Approx. 4 hours
2. AC adapter speci cations
Standard : AD-S12500A
Input : 100-240V AC, 50/60 Hz, 1.5A
Output : 12V DC, 5A
3. Dimensions, weight
Dimensions : Approx. 172(W) × 100(D) × 83(H) mm
Weight : Approx. 483g
4. Operating environment
Operating temperature : 0°C to 40°C
Operating humidity : 30-80% RH (condensation-free)